HP Brocade 8/24c Brocade Fabric OS Message Reference - Supporting Fabric OS v7
HP Brocade 8/24c Manual
View all HP Brocade 8/24c manuals
Add to My Manuals
Save this manual to your list of manuals |
HP Brocade 8/24c manual content summary:
- HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 1
53-1002448-01 ® 15 December 2011 Fabric OS Message Reference Supporting Fabric OS v7.0.1 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 2
copy of the programming source code, please visit http://www.brocade.com/support/oscd. Brocade Communications Systems, Incorporated Corporate and Latin American Headquarters Brocade Communications Systems, Inc. 130 Holger Way San Jose, CA 95134 Tel: 1-408-333-8000 Fax: 1-408-333-8101 E-mail: info - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 3
,SYSM, TRCE, ZOLB, ZONE. -Deleted USWD chapter. -Updated Introductory chapters. -Updated throughout: rebranding, supported hardware, CLI changes. June 2007 Fabric OS Message Reference 53-1000600-01 Updated for Fabric OS v6.0.0: -Added new chapters: C2, ESS, FICON -Added new messages to: AG, BL - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 4
Title Fabric OS Message Reference Fabric OS Message Reference Fabric OS Message Reference Fabric OS Message Reference Publication Summary of changes Date number 53-1001157-01 Updated for Fabric OS v6.2.0: -Revised and added new messages to FSS, KSWD, CTAP, CNM, CVLM, EM, FABR, FCIP, FW, HIL, - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 5
Fabric OS Message Reference Fabric OS Message Reference Publication Summary of changes Date number 53-1002149-01 Updated for Fabric OS v7 and RAS. -Updated Introductory chapter. April 2011 53-1002448-01 Updated for Fabric OS v7.0.1: -Added new messages: BL, CVLC, FICON, FSPF, and PS - - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 6
- HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 7
Notes, cautions, and warnings lxxxiii Key terms lxxxiii Notice to the reader lxxxiii Additional information lxxxiv Brocade 4 Configuring the syslog message destinations 4 System logging daemon 4 System console 5 SNMP management station 6 Port logs 7 Fabric OS Message Reference vii - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 8
recipient 10 Changing the severity level of swEventTrap 11 Commands for displaying and configuring the system message logs 13 Displaying and clearing system message logs 15 Viewing RASLog messages from Web Tools 15 Displaying RASLog messages 15 Displaying RASLog messages one message at a time - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 9
AG-1039 46 AG-1040 46 AG-1041 46 AN System Messages AN-1001 47 AN-1002 47 AN-1003 47 AN-1004 48 Fabric OS Message Reference ix 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 10
AUTH-1012 58 AUTH-1013 58 AUTH-1014 58 AUTH-1016 59 AUTH-1017 59 AUTH-1018 59 AUTH-1020 59 AUTH-1022 60 x Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 11
BL-1000 71 BL-1001 71 BL-1002 71 BL-1003 72 BL-1004 72 BL-1006 72 BL-1007 73 BL-1008 73 Fabric OS Message Reference xi 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 12
-1038 82 BL-1039 83 BL-1041 83 BL-1045 83 BL-1046 84 BL-1047 84 BL-1048 84 BL-1049 84 xii Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 13
95 Chapter 11 C2 System Messages C2-1001 97 C2-1002 97 C2-1004 97 C2-1006 98 C2-1007 98 C2-1008 98 Fabric OS Message Reference xiii 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 14
107 C3-1021 108 Chapter 13 CAL System Messages CAL-1001 109 Chapter 14 CCFG System Messages CCFG-1001 111 CCFG-1002 111 xiv Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 15
-1019 119 Chapter 16 CER System Messages CER-1001 121 Chapter 17 CHS System Messages CHS-1002 123 CHS-1003 123 CHS-1004 123 Fabric OS Message Reference xv 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 16
-1027 131 CNM-1028 132 CNM-1029 132 CNM-1030 132 CNM-1031 132 CNM-1032 133 CNM-1033 133 CNM-1034 133 xvi Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 17
Fabric OS Message Reference 53-1002448-01 CNM-1035 133 CNM-1036 134 CNM-1037 134 CNM-1038 134 CNM-1039 134 CNM-1040 135 CNM-1041 135 CNM- - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 18
-1007 152 CVLC-1008 153 CVLC-1009 153 CVLC-1010 153 CVLC-1011 154 CVLC-1012 154 CVLC-1013 154 CVLC-1014 155 xviii Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 19
CVLM-1005 164 CVLM-1006 164 CVLM-1007 164 CVLM-1008 165 CVLM-1009 165 CVLM-1010 165 CVLM-1011 165 CVLM-1012 166 Fabric OS Message Reference xix 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 20
System Messages DOT1-1001 175 DOT1-1002 175 DOT1-1003 175 DOT1-1004 175 DOT1-1005 176 DOT1-1006 176 DOT1-1007 176 xx Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 21
DOT1-1008 176 DOT1-1009 177 DOT1-1010 177 Chapter 24 ECC System Messages ECC-1000 179 ECC-1001 179 Chapter 25 EM System Messages EM-1001 181 EM-1002 181 1031 187 EM-1033 188 EM-1034 188 EM-1035 189 EM-1036 189 EM-1037 189 EM-1042 190 Fabric OS Message Reference xxi 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 22
-1001 199 ESS-1002 199 ESS-1003 199 ESS-1004 200 ESS-1005 200 ESS-1008 200 ESS-1009 200 ESS-1010 201 xxii Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 23
FABR-1016 214 FABR-1017 214 FABR-1018 214 FABR-1019 215 FABR-1020 215 FABR-1021 215 FABR-1022 216 FABR-1023 216 Fabric OS Message Reference xxiii 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 24
-1004 225 FABS-1005 226 FABS-1006 226 FABS-1007 226 FABS-1008 227 FABS-1009 227 FABS-1010 227 FABS-1011 227 xxiv Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 25
FCOE-1015 240 FCOE-1016 240 FCOE-1017 240 FCOE-1018 240 FCOE-1019 241 FCOE-1021 241 FCOE-1022 241 FCOE-1023 241 Fabric OS Message Reference xxv 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 26
FCPH-1001 251 FCPH-1002 251 FCPH-1003 251 FCPH-1004 252 FCPH-1005 252 Chapter 37 FCR System Messages FCR-1001 253 xxvi Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 27
Fabric OS Message Reference 53-1002448-01 FCR-1002 253 FCR-1003 253 FCR-1004 253 FCR-1005 254 FCR-1006 254 FCR-1007 254 FCR-1008 255 FCR- - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 28
-1077 272 FCR-1078 273 FCR-1079 273 FCR-1080 273 FCR-1081 274 FCR-1082 274 FCR-1083 274 FCR-1084 274 xxviii Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 29
FICN-1021 285 FICN-1022 285 FICN-1023 286 FICN-1024 286 FICN-1025 286 FICN-1026 287 FICN-1027 287 FICN-1028 287 Fabric OS Message Reference xxix 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 30
-1058 296 FICN-1059 297 FICN-1060 297 FICN-1061 297 FICN-1062 298 FICN-1063 298 FICN-1064 298 FICN-1065 299 xxx Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 31
Fabric OS Message Reference 53-1002448-01 FICN-1066 299 FICN-1067 299 FICN-1068 299 FICN-1069 300 FICN-1070 300 FICN-1071 300 FICN-1072 301 FICN- - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 32
FICN-2087 320 Chapter 39 FICU System Messages FICU-1001 321 FICU-1002 321 FICU-1003 321 FICU-1004 322 FICU-1005 322 xxxii Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 33
FSPF-1002 331 FSPF-1003 331 FSPF-1005 332 FSPF-1006 332 FSPF-1007 332 FSPF-1008 332 FSPF-1009 333 FSPF-1010 333 Fabric OS Message Reference 53-1002448-01 xxxiii - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 34
-1035 344 FW-1036 344 FW-1037 344 FW-1038 345 FW-1039 345 FW-1040 345 FW-1041 346 FW-1042 346 xxxiv Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 35
Fabric OS Message Reference 53-1002448-01 FW-1043 346 FW-1044 347 FW-1045 347 FW-1046 347 FW-1047 348 FW-1048 348 FW-1049 348 FW- - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 36
-1186 368 FW-1187 368 FW-1188 369 FW-1189 369 FW-1190 369 FW-1191 370 FW-1192 370 FW-1193 370 xxxvi Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 37
Fabric OS Message Reference 53-1002448-01 FW-1194 371 FW-1195 371 FW-1196 371 FW-1197 372 FW-1198 372 FW-1199 372 FW-1200 373 FW- - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 38
FW-1373 393 FW-1374 393 FW-1375 394 FW-1376 394 FW-1377 395 FW-1378 395 FW-1379 395 FW-1400 396 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 39
Fabric OS Message Reference 53-1002448-01 FW-1401 396 FW-1402 396 FW-1403 397 FW-1404 397 FW-1405 397 FW-1406 397 FW-1407 398 FW- - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 40
-3014 417 FW-3015 417 FW-3016 417 FW-3017 417 FW-3018 418 FW-3019 418 FW-3020 418 FW-3021 419 xl Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 41
HIL-1107 431 HIL-1108 431 HIL-1201 431 HIL-1202 432 HIL-1203 432 HIL-1204 432 HIL-1206 433 HIL-1207 433 Fabric OS Message Reference xli 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 42
-1602 441 HIL-1603 442 HIL-1605 442 HIL-1610 442 HIL-1611 442 HIL-1612 443 HIL-1613 443 HIL-1650 443 xlii Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 43
457 Chapter 55 ICPD System Messages ICPD-1001 459 ICPD-1002 459 ICPD-1003 459 ICPD-1004 459 ICPD-1005 460 ICPD-1006 460 Fabric OS Message Reference xliii 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 44
ISNS-1013 472 ISNS-1014 472 Chapter 59 KAC System Messages KAC-1002 473 KAC-1004 473 KAC-1006 473 KAC-1007 474 xliv Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 45
-1007 482 L2SS-1008 483 Chapter 63 L3SS System Messages L3SS-1004 485 Chapter 64 LACP System Messages LACP-1001 487 LACP-1002 487 Fabric OS Message Reference xlv 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 46
-1004 497 MCAST_SS-1005 498 MCAST_SS-1006 498 MCAST_SS-1007 498 MCAST_SS-1008 498 MCAST_SS-1009 499 MCAST_SS-1010 499 MCAST_SS-1011 499 xlvi Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 47
MS-1005 511 MS-1006 511 MS-1008 511 MS-1009 512 MS-1021 512 MS-1022 512 MS-1023 513 MS-1024 513 Fabric OS Message Reference xlvii 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 48
NS-1008 523 NS-1009 523 NS-1010 523 NS-1011 524 NS-1012 524 Chapter 77 NSM System Messages NSM-1001 525 xlviii Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 49
PDM-1001 533 PDM-1002 533 PDM-1003 533 PDM-1004 534 PDM-1005 534 PDM-1006 534 PDM-1007 534 PDM-1008 535 Fabric OS Message Reference xlix 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 50
PMGR-1003 545 PMGR-1004 545 PMGR-1005 546 PMGR-1006 546 PMGR-1007 546 PMGR-1008 546 PMGR-1009 547 PMGR-1010 547 l Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 51
558 PSWP-1006 558 PSWP-1007 558 Chapter 86 RAS System Messages RAS-1001 559 RAS-1002 559 RAS-1004 559 RAS-1005 560 Fabric OS Message Reference li 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 52
568 RKD-1005 568 Chapter 89 RMOND System Messages RMON-1001 569 RMON-1002 569 Chapter 90 RPCD System Messages RPCD-1001 571 lii Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 53
SEC-1022 582 SEC-1024 582 SEC-1025 583 SEC-1026 583 SEC-1028 583 SEC-1029 584 SEC-1030 584 SEC-1031 584 Fabric OS Message Reference liii 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 54
-1071 593 SEC-1072 593 SEC-1073 594 SEC-1074 594 SEC-1075 594 SEC-1076 595 SEC-1077 595 SEC-1078 595 liv Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 55
Fabric OS Message Reference 53-1002448-01 SEC-1079 595 SEC-1080 596 SEC-1081 596 SEC-1082 596 SEC-1083 597 SEC-1084 597 SEC-1085 597 SEC- - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 56
-1168 615 SEC-1170 615 SEC-1171 616 SEC-1172 616 SEC-1173 616 SEC-1174 616 SEC-1175 617 SEC-1176 617 lvi Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 57
Fabric OS Message Reference 53-1002448-01 SEC-1180 617 SEC-1181 617 SEC-1182 618 SEC-1183 618 SEC-1184 618 SEC-1185 619 SEC-1186 619 SEC- - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 58
-3036 637 SEC-3037 637 SEC-3038 637 SEC-3039 637 SEC-3050 638 SEC-3051 638 SEC-3061 638 SEC-3062 638 lviii Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 59
SPC-1002 649 SPC-1003 649 SPC-2001 650 SPC-2002 650 SPC-2003 650 SPC-2004 650 SPC-2005 651 SPC-2006 651 Fabric OS Message Reference lix 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 60
System Messages SPM-1001 661 SPM-1002 661 SPM-1003 661 SPM-1004 661 SPM-1005 662 SPM-1006 662 SPM-1007 662 lx Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 61
Fabric OS Message Reference 53-1002448-01 SPM-1008 662 SPM-1009 663 SPM-1010 663 SPM-1011 663 SPM-1012 663 SPM-1013 664 SPM-1014 664 SPM- - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 62
-1206 681 SSMD-1207 681 SSMD-1208 681 SSMD-1209 682 SSMD-1210 682 SSMD-1211 682 SSMD-1212 683 SSMD-1213 683 lxii Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 63
SULB-1005 692 SULB-1006 692 SULB-1007 692 SULB-1008 693 SULB-1009 693 SULB-1010 699 SULB-1011 699 SULB-1017 699 Fabric OS Message Reference lxiii 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 64
-1005 708 SWCH-1006 708 SWCH-1007 708 SWCH-1008 709 SWCH-1009 709 SWCH-1010 709 SWCH-1011 710 SWCH-1012 710 lxiv Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 65
TRCE System Messages TRCE-1001 721 TRCE-1002 721 TRCE-1003 722 TRCE-1004 722 TRCE-1005 722 TRCE-1006 722 TRCE-1007 723 Fabric OS Message Reference lxv 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 66
UCST-1024 730 UCST-1025 731 UCST-1026 731 UCST-1027 731 Chapter 110 UPTH System Messages UPTH-1001 733 UPTH-1002 733 lxvi Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 67
XTUN-1999 743 XTUN-2000 743 XTUN-2001 744 XTUN-2002 744 XTUN-2003 744 XTUN-2004 744 XTUN-2005 745 XTUN-2006 745 Fabric OS Message Reference lxvii 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 68
-1010 755 ZONE-1012 755 ZONE-1013 756 ZONE-1014 756 ZONE-1015 756 ZONE-1017 756 ZONE-1018 757 ZONE-1019 757 lxviii Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 69
Fabric OS Message Reference 53-1002448-01 ZONE-1022 758 ZONE-1023 758 ZONE-1024 758 ZONE-1026 758 ZONE-1027 759 ZONE-1028 759 ZONE-1029 759 ZONE- - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 70
-3005 779 AUTH-3006 779 AUTH-3007 780 AUTH-3008 780 Chapter 119 AUDIT BLS System Messages BLS-1002 781 BLS-1003 781 lxx Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 71
CVLM-3004 792 CVLM-3005 792 CVLM-3006 792 CVLM-3007 792 CVLM-3008 793 CVLM-3009 793 CVLM-3010 793 CVLM-3011 794 Fabric OS Message Reference lxxi 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 72
-1019 805 FICU-1020 806 FICU-1021 806 Chapter 127 AUDIT FW System Messages FW-1202 807 FW-1274 807 FW-1402 807 lxxii Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 73
1002 813 Chapter 130 AUDIT MS System Messages MS-1027 815 MS-1028 815 MS-1029 815 Chapter 131 AUDIT PMGR System Messages PMGR-1001 817 PMGR-1003 817 Chapter 132 AUDIT PORT System Messages PORT-1006 819 PORT-1007 819 PORT-1008 819 PORT-1009 820 Chapter 133 AUDIT RAS System Messages RAS-2001 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 74
SEC-3005 825 SEC-3006 825 SEC-3007 825 SEC-3008 826 SEC-3009 826 SEC-3010 826 SEC-3011 826 SEC-3012 827 SEC-3013 827 SEC-3014 827 SEC-3015 SEC-3035 834 SEC-3036 834 SEC-3037 834 SEC-3038 834 SEC-3039 835 SEC-3044 835 SEC-3045 835 lxxiv Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 75
SPM-3008 845 SPM-3009 845 SPM-3010 845 SPM-3011 846 SPM-3012 846 SPM-3013 846 SPM-3014 846 SPM-3015 847 Fabric OS Message Reference lxxv 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 76
-1030 862 SULB-1031 863 SULB-1032 863 SULB-1033 863 SULB-1034 864 SULB-1035 864 SULB-1037 864 SULB-1038 865 lxxvi Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 77
ZONE-3011 876 ZONE-3012 876 ZONE-3013 876 ZONE-3014 877 ZONE-3015 877 ZONE-3016 877 ZONE-3017 878 ZONE-3018 878 Fabric OS Message Reference 53-1002448-01 lxxvii - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 78
ZONE-3019 878 ZONE-3020 878 ZONE-3021 879 ZONE-3022 879 ZONE-3023 879 ZONE-3024 880 ZONE-3025 880 lxxviii Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 79
Systems, Inc. for Fabric OS 7.0.1, documenting all possible configurations and scenarios is beyond the scope of this document. The following hardware platforms are supported by this release of Fabric OS: • Brocade 300 • Brocade 5100 • Brocade 5300 Fabric OS Message Reference lxxix 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 80
Brocade DCX 8510-8 Backbone and Brocade DCX 8510-4 Backbone - FC8-32E port blade - FC8-48E port blade - FC8-64 port blade - FC16-32 port blade - FC16-48 port blade - FS8-18 Encryption Blade - FX8-24 DCX Extension Blade • Brocade VA-40FC The following hardware platforms are not supported in Fabric OS - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 81
supported in any chassis operating with Fabric OS v7.0.1: • FA4-18 • FC4-16IP • FC4-16 • FC4-32 • FC4-48 What's new in this document The following changes have been made since this document was last released this release, refer to the release notes. Fabric OS Message Reference lxxxi 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 82
configuration tasks using the Fabric OS command line interface, but does not describe the commands in detail. For complete descriptions of all Fabric OS commands, including syntax, operand description, and sample output, see the Fabric OS Command Reference. lxxxii Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 83
or situations. Key terms For definitions specific to Brocade and Fibre Channel, see the technical glossaries on MyBrocade. See "Brocade resources" on page lxxxiv for instructions on accessing MyBrocade. For definitions of SAN-specific terms, visit the Storage Networking Industry Association - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 84
://www.t11.org For information about the Fibre Channel industry, visit the Fibre Channel Industry Association website: http://www.fibrechannel.org Getting technical help Contact your switch support supplier for hardware, firmware, and software support, including product repairs and part ordering. To - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 85
8000, VA-40FC, and Brocade Encryption Switch-On the switch ID pull-out tab located inside the chassis on the port side on the left • Brocade 5410, 5424, 5450, 5460, 5470, 5480-Serial number label attached to the module • Brocade DCX and DCX 8510-8-On the port Brocade [email protected] Provide - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 86
lxxxvi Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 87
, and configuring Audit messages 16 •Reading the system messages 18 •Responding to a system message 21 •System module descriptions 23 Overview of system messages This guide supports Fabric OS v7.0.1 and documents system messages that can help you diagnose and fix problems with a switch or fabric - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 88
Configuration uploads are not audited. 5 Fabric You can audit Administration Domain-related changes. 6 FW You can audit Fabric Watch (FW)-related changes. 7 LS You can audit Virtual Fabric (Logical Switch)-related changes. Fabric OS v7.0.1 generates component-specific Audit messages. Refer - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 89
to configure event auditing, refer to "Displaying, clearing, and configuring Audit messages" on page 16. FFDC messages First Failure Data Capture (FFDC) is used to capture failure-specific data when a problem or failure is first noted before the switch reboots, or trace and log buffer get wrapped - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 90
or any other operating system that supports the standard syslogd functionality. Configuring for syslogd involves configuring the host, enabling syslogd on the Brocade model, and, optionally, setting the facility level. For the Brocade DCX family of switches, each control processor (CP) has a unique - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 91
Configuring the syslog message destinations 1 For the Brocade DCX family of switches, any security violations that occur through Telnet, HTTP, level for the console to ERROR, enter the following command. switch:admin> errfilterset -d console -v error Fabric OS Message Reference 5 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 92
to verify the configured filter settings. switch:admin> errfilterset console: filter severity = ERROR SNMP management station When an unusual event, error, or a status change occurs on the device, an event notification is sent to the SNMP management station. Fabric OS v7.0.1 supports two types of - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 93
. Brocade devices support SNMPv3 informs. For more information, refer to "Configuring the SNMPv3 inform recipient" on page 10. Port logs The Fabric OS maintains an internal log of all port activity. Each switch or logical switch maintains a log file for each port. Port logs are circular buffers that - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 94
configuration. switch:admin> snmpconfig --show snmpv1 SNMPv1 community and trap recipient configuration: Community 1: Secret C0de (rw) Trap recipient: 10.24.32.122 Trap port .brocade.com Trap port: 162 Trap recipient Severity level: 5 Community 4: public (ro) Trap recipient: 172.26.4.52 Trap port: - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 95
: [10.24.32.143] [...] NOTE To receive the SNMP traps, the username, the authentication protocol, and the privacy protocol must match between the switch and the management station. 3. Execute the snmpConfig --show snmpv3 command to verify the SNMP agent configuration. switch:admin> snmpconfig --show - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 96
true or t. Informs are disabled by default. switch:admin> snmpconfig --set snmpv3 SNMP Informs Enabled (true, t, false, f): [false] t SNMPv3 user configuration(snmp user not configured in FOS user database will have physical AD and admin role as the default): User (rw): [snmpadmin1] Auth Protocol - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 97
configuration.....done. NOTE To receive the SNMP informs, the username, the authentication protocol, the privacy protocol, and the engine ID must match between the switch and the management station. 3. Execute the snmpConfig --show snmpv3 command to verify the SNMP agent configuration. switch:admin - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 98
configure MIBs interactively. All the supported MIBs and associated traps are displayed. You can change the DesiredSeverity for swEventTrap to 1 (Critical), 2 (Error), 3 (Warning), or 4 (Informational). The default value is 0. switch:admin bdTrap: YES 12 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 99
the severity level of swEventTrap. switch:admin> snmpconfig --show mibcapability FE- configure the system message logs. Most commands require the admin access level. For detailed information on required access levels and commands, refer to the Fabric OS Command Reference. Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 100
an event to report to the port log. Port log events are described by the portLogEventShow command. Sets the verbose level of a particular module within the Fabric OS. Manages the SNMP agent configuration. Enables and disables FFDC. Sets, clears, or displays support FTP parameters or a time interval - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 101
OS module trace dump. Displaying and clearing system message logs This section provides information on viewing and clearing RASLog messages. These procedures are valid for all the supported platforms. Viewing RASLog messages from Web Tools To view the system message log for a switch from Web Tools - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 102
are valid for all the supported platforms. Displaying Audit messages To display the Audit messages, perform the following steps. 1. Log in to the switch as admin. 2. Enter the auditDump -s command at the command line. switch:admin> auditdump -s 16 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 103
, and CRITICAL switch:admin> auditcfg --severity ERROR 5. Execute the auditCfg --show command to verify the configuration. switch:admin> auditcfg --show Audit filter is enabled. 1-ZONE 2-SECURITY 3-CONFIGURATION 4-FIRMWARE 5-FABRIC 6-FW 7-LS Severity level: ERROR Fabric OS Message Reference 17 53 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 104
, - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 105
post-event auditing and troubleshooting the problem. The following example shows the format of the Audit event message. AUDIT, , [], , , ////, /, - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 106
generated on the switch. The RASLog subsystem will support an internationalized time stamp format based on the "LOCAL" setting. The message module and number. These values uniquely identify each message in the Fabric OS and reference the cause and actions recommended in this manual. Note that not - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 107
Questions to ask yourself when troubleshooting a system message are as follows: • What is the current Fabric OS level? • What is the switch hardware version? • Is the switch operational? • Assess impact and urgency: - Is the switch down? - Is it a standalone switch? - How large is the fabric? - Is - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 108
switch. • Execute the supportFtp command (as needed) to set up automatic FTP transfers, and then execute the supportSave command. Support Fabric OS creates a number of files that can help support personnel troubleshoot and diagnose a problem a complete listing of daemons, refer to the KSWD entry in - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 109
for third-generation hardware platforms. Fibre Channel over IP port configuration message over the Brocade 7800 and FX8-24 blade. Blade management error messages are a result of autoleveling firmware upgrades performed by the control processor (CP). Condor2 error messages indicate problems with the - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 110
problems with the 802.1x authentication module of the Fabric OS. switches in the fabric. Fabric OS system driver module. Firmware blade compatibility errors with the control processor (CP). Fibre Channel over IP port configuration messages. Fibre Channel miscellaneous messages relate to problems - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 111
. Moreover, ICPD distributes iSCSI configurations not only switch-wide, but also fabric-wide. It keeps of track iSCSI VT status and updates VT status to BP. System messages generated by the IP admin demon. Fibre Channel over IP license, tunneling, and port-related messages. ISNS server and - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 112
Switch Support daemon (essd) • FA-API rpc daemon (rpcd) • Fabric daemon (fabricd) • Fabric Watch daemon (fwd) • FCoE daemon (fcoed) • Fibre Channel services module daemon (ssmd) • Time Service daemon (tsd) • TRACE daemon (traced) • Traffic daemon (trafd) 26 Fabric OS Message Reference 53 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 113
queue. MS The Management Service enables the user to obtain information about the Fibre Channel fabric topology and attributes by providing a single management access point. MS provides for both monitoring and control of the following areas: • Fabric Configuration Server: Provides for the - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 114
trace files have been created. PLAT messages indicate hardware problems. A group of messages relating to logical switch creation, deletion, and configuration. PORT error messages refer to the front-end user ports on the switch. Front-end user ports are directly accessible by users to connect end - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 115
informational only and are generated even during successful firmware download. For additional information, refer to the Fabric OS Administrator's Guide. These messages are generated by the switch driver module that manages a Fibre Channel switch instance. System controller is a daemon that starts up - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 116
(FTRACE buffer status changes). Zeus error messages indicate problems with the Zeus driver module. The zone module messages indicate any problems associated with the zoning features, including commands associated with aliases, zones, and configurations. 30 Fabric OS Message Reference 53-1002448 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 117
•FABR System Messages 209 •FABS System Messages 225 •FBC System Messages 231 •FCIP System Messages 233 •FCMC System Messages 235 •FCOE System Messages 237 Fabric OS Message Reference 31 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 118
System Messages 495 •MCAST_SS System Messages 497 •MFIC System Messages 503 •MPTH System Messages 505 •MQ System Messages 507 •MS System Messages 509 32 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 119
Messages 533 •PDTR System Messages 541 •PLAT System Messages 543 •PMGR System Messages 545 •PORT System Messages 549 •PS System Messages 553 •PSWP System Messages 557 •RAS System Messages 733 •VS System Messages 735 •WEBD System Messages 739 Fabric OS Message Reference 33 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 120
•XTUN System Messages 741 •ZEUS System Messages 749 •ZONE System Messages 753 34 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 121
and they will not respond to NPIV requests. Refer to the Access Gateway Administrator Guide, Appendix B, for specific AG-compatibility requirements. • On non-Brocade switches, refer to the manufacturer's documentation to determine whether the switch supports NPIV and how to enable NPIV on these - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 122
. Probable Cause Indicates the fabric sent an invalid response to the FLOGI Extended Link Service (ELS) for the specified N_Port. Recommended Action Check the configuration of the fabric switch. of the Access Gateway mode. Action Severity INFO 36 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 123
, , Sending FLOGI failed on N_Port . Probable Cause Indicates there was a failure sending a Fabric Login (FLOGI) request from the Access Gateway to the fabric switch. Recommended Action Check the configuration of the fabric switch connected to the Access Gateway. If the message - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 124
port>. Probable Cause Indicates there was a failure sending discover F_Port service parameter request from the Access Gateway to the fabric switch. Recommended Action Check the configuration of the fabric switch -N_Port mapping. Action Severity INFO 38 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 125
configured. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportsave command and contact your switch service configured in the system or all configured N_Ports have failed to come online. Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 126
, , Unable to failover N_Port . No other N_Port in port group: is online. Probable Cause Indicates that failover across port groups is not supported. Recommended Check whether an alternate N_Port is configured in this port group. Action Severity WARNING AG-1020 Message - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 127
, , Unable to do Preferred-Failover of F_Port . Failover across different fabric is not supported. Probable Cause Indicates that failover across N_Ports connected to different fabrics , which are failed over to some other N_Port. Fabric OS Message Reference 41 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 128
. Execute the configure command on the Access Gateway switch and increase the number of allowed logins on this port. If the message persists, execute the supportFtp (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. WARNING - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 129
Message Probable Cause , [AG-1031], ,, WARNING, , Loop Detected for device with Port WWN connected to port Indicates that the routing loop is detected for the device connected to the port. Fabric OS Message Reference 43 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 130
2 AG-1032 Recommended Check the device configuration. Action Severity WARNING AG-1032 Message , [AG-1032], ,, INFO, , N_Port (ID: ) has recovered from an unreliable state. Probable Cause Indicates that the port state has been stable for the last - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 131
1036], ,, WARNING, ,Port is connected to a Non-Brocade fabric with Persistent ALPA enabled. Check the admin guide for supported configuration. Probable Cause Indicates that one of the ports is connected to a non-Brocade fabric. Recommended No action is required - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 132
port reset was not an error. Action Severity INFO AG-1040 Message , [AG-1040], ,, WARNING, , PID of the devices connected to Port may have changed, as the port was toggled. Check EE monitor's configuration Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 133
bottleneck. Recommended If the port is an F_Port, examine the connected device for the source of the latency. If the port is a Action long-distance E_Port, ensure that there are enough buffer credits to service the link distance. Severity WARNING Fabric OS Message Reference 47 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 134
bottleneck on slot port because port mirroring is enabled on this port. Indicates that resources needed to determine whether there is complete credit loss on a VC at this port are in use by port mirroring. 48 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 135
, , Performed link reset to recover the port credits on slot port . Probable Cause Indicates a credit loss. Recommended The port is recovered. No action is required. Action Severity WARNING Fabric OS Message Reference 49 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 136
3 AN-1013 50 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 137
are used on the peer ports, the SFPs have not deteriorated, and the Action fibre channel cable is not faulty. Replace the SFPs or the cable, if necessary. Severity ERROR ANV-1002 Message , [ANV-1002], , FFDC, ERROR, , Port chip faulted due - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 138
> 0x. Probable Cause Indicates that Anvil Pass 1 is running out of free buffers, which may cause chip fault. Recommended Power cycle the faulted blade. If the problem persists, replace the faulted blade. Action Severity CRITICAL 52 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 139
, , Port reinitialized due to Link Reset failure on internal port S, P(). Probable Cause Indicates that the specified port was reinitialized due to link reset failure. Recommended Power cycle the faulted blade. If the problem persists - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 140
4 ANV-1016 54 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 141
set to . Indicates that an authentication configuration value was set to the specified value. The data type is either authentication type, DH group type, or policy type. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 55 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 142
command and contact your switch service provider. Severity ERROR AUTH-1006 Message , [AUTH-1006], ,, WARNING, , Failed to open authentication configuration file. Probable Cause Indicates an internal problem with the Secure Fabric OS. Recommended Action - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 143
sure the local switch supports the specified protocols: Fibre channel authentication protocol (FCAP) or Diffie Hellman - challenge handshake authentication protocol (DH the supportSave command and contact your switch service provider. Severity WARNING Fabric OS Message Reference 57 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 144
contact your switch service provider. Severity WARNING AUTH-1014 Message , [AUTH-1014], , FFDC, ERROR, , Invalid port value to : port . Probable Cause Indicates an internal problem with the Secure Fabric OS. Recommended Action - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 145
-name>, Invalid value to start HBA authentication port: , . Probable Cause This may relate to an internal failure. Recommended Copy the message, collect switch information using the supportShow command, and contact your Action switch service provider. Severity ERROR AUTH-1017 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 146
Operation type varies depending on authentication type: • Some operations for switch link authentication protocol (SLAP): certificate retrieve, certificate verification, signature verification, or nonce signing. • Some operations for fibre channel authentication protocol (FCAP): certificate retrieve - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 147
for the specified authentication phase. This indicates that the local switch does not support the specified authentication value. Recommended Check the authentication configuration and reset the supported value if needed using the authUtil Action command. Fabric OS Message Reference 61 53 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 148
and contact your switch service provider. Severity ERROR AUTH-1028 Message , [AUTH-1028], ,, ERROR, , Failed to allocate for : port . Probable Cause Indicates that the authentication process failed because - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 149
your switch service provider. Severity ERROR AUTH-1031 Message , [AUTH-1031], ,, ERROR, , Failed to retrieve secret value: port . Probable Cause Indicates that the secret value was not set properly for the authenticated entity. Recommended - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 150
configured in the switch connection control (SCC) policy and tried to connect to the port. Recommended Add the entity's world wide name (WWN) to the SCC policy and reinitialize authentication and contact your switch service provider. Severity ERROR 64 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 151
state for : port . Probable Cause Indicates that the switch received an unexpected authentication message. Recommended Action Usually this problem is transient. The authentication might fail. Reinitialize authentication using the portDisable and - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 152
reinitialize authentication using the portDisable and portEnable commands. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR 66 Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 153
for F_Port authentication failed. Device authentication will be defaulted to OFF, and switch will not participate in Diffie Hellman - challenge handshake authentication protocol (DH-CHAP) authentication with devices. Recommended Try setting the device authentication policy manually using the - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 154
switch in port . Probable Cause Indicates that the public key infrastructure (PKI) certificate is not installed in this switch run the supportSave command and contact your switch service provider. Severity ERROR 68 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 155
the system. Refer to the Warning message variable for specific information. The switch will reboot (on single-CP switches) or fail over (on dual-CP switches). The Action supportSave command and contact your switch service provider. Severity WARNING Fabric OS Message Reference 69 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 156
6 BKSW-1003 70 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 157
to ensure that Power-On Self-Test (POST) is enabled. Additional blade fault messages precede and follow this error, providing more information. See other error messages for recommended action. If the message persists, replace the blade. Severity CRITICAL Fabric OS Message Reference 71 53-1002448 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 158
cycle the blade, using the slotPowerOff and slotPowerOn commands. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on these commands. If the message persists, replace the blade. Severity CRITICAL BL-1006 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 159
-specific integrated circuit (ASIC) chips. Recommended Action Make sure that the blade is seated correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 160
the hardware settings. Probable Cause Indicates that a failover occurred while some hardware SFP), or device attached to the specified port. On a bladed switch, run the slotPowerOff and slotPowerOn commands. On a nonbladed switch, restart or power cycle the switch. 74 Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 161
process. Check for a faulty cable, small form-factor pluggable (SFP), or device attached to the specified port. On a bladed switch, run the slotPowerOff and slotPowerOn commands. On a nonbladed switch, restart or power cycle the switch. If the message persists, replace the blade. Severity ERROR BL - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 162
commands. On a nonbladed switch, reboot the switch. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. If there is a hardware error, if the slotPowerOff or slotPowerOn fails on the bladed switch or if errors are encountered again: • On the Brocade 24000, and 48000, replace - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 163
has failed to initialize the application-specific integrated circuit (ASIC) chips. Recommended Action Restart or power cycle the switch. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on these commands - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 164
because one or more of the internal ports was not online. The switch is faulted. Recommended Action Restart or power cycle the switch. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on these commands - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 165
Probable Cause Indicates that a recent firmware upgrade caused the blade's firmware to be upgraded and resulted in the cold upgrade. As part of the upgrade, all GbE or Fibre Channel over IP (FCIP) or Virtualization data elements or FC Fastwrite ports were reset. Recommended No action is required - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 166
processor firmware to be upgraded and resulted in the cold upgrade. As part of the upgrade, all the GbE or Fibre Channel over IP (FCIP) or Virtualization data elements or FC Fastwrite ports were reset. Recommended No action is required. Action Severity INFO 80 Fabric OS Message Reference 53 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 167
link timeout occurred in one of the backend internal ports. Recommended Power cycle the blade or run the slotPowerOff and slotPowerOn FC Initialization completed. Indicates that the slot has completed initializing Fibre Channel (FC) ports. Fabric OS Message Reference 81 53-1002448 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 168
Probable Cause , [BL-1038], ,, CRITICAL, , Inconsistent FPGA image version detected, please reboot the switch for recovery. Indicates that the FPGA image version is incompatible with the software version. 82 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 169
area mode on default switch. Recommended Turn off the dynamic area mode through Configure CLI. Action Severity CRITICAL BL-1045 Message , [BL-1045], ,, ERROR, , mini SFP+ (SN: ) is only supported in certain high port count blades - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 170
SFP> error on SFP in Slot /Port - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 171
. Probable Cause Indicates that the blade processor FPGA version with Fabric OS v7.0.0 firmware is incompatible on the Brocade 7800 switch. Recommended Contact your switch service provider for upgrade instructions. Action Severity WARNING Fabric OS Message Reference 85 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 172
7 BL-1051 86 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 173
problem was reported on the specified slot. The blade is faulted. The possible reason codes are as follows: • 1 = Available buffer overflow • 2 = Backend port buffer timeout • 3 = Backend port was shut down • 4 = Embedded port buffer open state • 18 = Wait for Old port state • 19 = Wait for Open init - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 174
that Power-On Self-Test (POST) is enabled; then power cycle the blade using the slotPowerOff and slotPowerOn commands or have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware problems. Severity CRITICAL 88 Fabric OS Message Reference 53-1002448 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 175
ID>. Probable Cause Indicates that the hardware is not responding to a command request and requires faulting the blade or switch. Recommended Retry the command. Action configuration file was updated. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 89 53 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 176
for the configuration. Probable Cause Indicates a deteriorated SFP, an incompatible SFP pair, or a faulty cable between the peer ports. Recommended Ensure that you are using compatible SFPs on the peer ports. Verify whether the SFPs have Action deteriorated and the Fibre Channel cable is faulty - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 177
. Refer to the release notes to determine whether a non-disruptive firmware download is supported between the revisions. Because the AP and CP blades cannot communicate, it is not possible to load new firmware on the AP blade. If needed, send the AP blade back to the factory for a firmware update - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 178
affected blade. On the Brocade Action 7500 or 7600, switch off and switch on all primary power to power-cycle the unit. Severity WARNING BM-1006 Message , [BM-1006], ,, INFO, , Blade is not configured. Persistently disabling all ports for blade in slot - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 179
. On the Brocade Action 7500 or 7600, switch off and switch on all primary power in order to power-cycle the unit. Severity WARNING BM-1010 Message Probable Cause , [BM-1010], ,, INFO, , Resetting port configuration and linkcost for all ports for blade in - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 180
(AP) blade has failed. Recommended Use the slotPowerOff and slotPowerOn commands or reseat the affected blade. On the Brocade Action DCX, 7500 or 7600, switch off and switch on all primary power in order to power-cycle the unit. Severity WARNING 94 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 181
• The switch was configured under a different mode. Recommended Configure the switch to persistently enable all ports. Action Severity INFO BM-1058 Message , [BM-1058], ,, WARNING, , Download of AP firmware failed for the switch. Reissue firmwaredownload - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 182
10 BM-1058 96 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 183
for the configuration. Probable Cause Indicates a deteriorated SFP, an incompatible SFP pair, or a faulty cable between the peer ports. Recommended Verify that you are using compatible SFPs on the peer ports. Verify that the SFPs have not Action deteriorated and the Fibre Channel cable is not - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 184
chip index>: Internal link errors reported, no hardware faults identified, continuing monitoring: fault1:, (): best effort QOS will be turned off at next port state change as it is not supported under this configuration. OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 185
seconds. Recommended Turn on the back-end credit recovery to reset the link and recover the lost credits. If credit recovery Action has already been turned on, the link will be reset to recover the credits and no action is required. Severity WARNING Fabric OS Message Reference 99 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 186
slot number>,P() vc_no= crd(s)lost=. Probable Cause Indicates that one or more credits are lost and the link is reset. Recommended Whenever this error is observed persistently, power cycle the specified blade. If the problem Action persists - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 187
the ports in the internal trunk. Recommended Whenever this error is observed persistently, power cycle the specified blade. If the problem Action to Link reset threshold exceeded. Recommended Whenever this error is observed persistently, power cycle the specified blade. If the problem Action - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 188
11 C2-1019 102 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 189
the configuration. Probable Cause Indicates a deteriorated small form-factor pluggable (SFP), an incompatible SFP pair, or a faulty cable between the peer ports. Recommended Verify that compatible SFPs are used on the peer ports, the SFPs have not deteriorated, and the Action Fibre Channel cable - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 190
slot number>,C: Various non critical hardware errors were observed: fault1:0x, port number>(): best effort QOS will be turned off at next port state change as it is not supported under this configuration. Probable Cause Indicates that Quality of Service - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 191
seconds. Recommended Turn on the back-end credit recovery to reset the link and recover the lost credits. If credit recovery Action has already been turned on, the link will be reset to recover the credits and no action is required. Severity WARNING Fabric OS Message Reference 105 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 192
Port S,P() vc_no= crd(s)lost=. Probable Cause Indicates that one or more credits are lost and the link is reset. Recommended Whenever this error is observed persistently, power cycle the specified blade. If the problem - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 193
ports in the internal trunk. Recommended Whenever this error is observed persistently, power cycle the specified blade. If the problem reset threshold exceeded. Recommended Whenever this error is observed persistently, power cycle the specified blade. If the problem the ASIC hardware that may - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 194
Cause Indicates that an internal error is observed in the ASIC hardware that may degrade the data traffic. Recommended Whenever this error occurs, software recovers from the error. If the problem persists, replace the Action blade. Severity WARNING 108 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 195
>,, INFO, , Switch offline requested by remote domain . Probable Cause Indicates a remote domain has requested the local domain to be disabled. Recommended See remote domain raslogs for the reason. Action Severity INFO Fabric OS Message Reference 109 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 196
13 CAL-1001 110 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 197
Enhanced Ethernet (CEE) configuration management daemon has failed. Recommended Download a new firmware version using the firmwareDownload CEE shell is ready to accept configuration commands. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 111 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 198
, [CCFG-1007], ,, INFO, , Startup configuration is deleted. Probable Cause Indicates that the startup configuration file has been moved or deleted. Recommended No action is required. Action Severity INFO 112 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 199
mismatch on slot . Probable Cause Indicates that the inserted linecard is different from the pre-configured linecard on the specified slot. Recommended Execute the no linecard command to remove the linecard configuration. Action Severity INFO Fabric OS Message Reference 113 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 200
the system ready event. Recommended Execute the slotPowerOff and slotPowerOn commands on the specified slot to bring the blade Action online. Severity ERROR 114 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 201
pair, a faulty cable between peer ports, or that the port speed configuration does not match the capability of the SFP. Recommended Action Ensure that you are using compatible SFPs on the peer ports. Verify whether the SFPs have not deteriorated and the Fibre Channel cable is not faulty. Replace - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 202
timestamp>, [CDR-1005], ,, WARNING, , S, P(): best effort QOS will be turned off at next port state change as it is not supported under this configuration. Probable Cause Indicates QoS will be turned off automatically at the - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 203
suspect hardware, blade may need to be reset or replaced hardware that may or may not impact data traffic. Recommended Whenever this error is observed persistently, power cycle the specified blade. If the problem Action persists, replace the blade. Severity CRITICAL Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 204
Port S,P() vc_no= crd(s)lost=. Probable Cause Indicates that one or more credits were lost and the link is reset. Recommended Whenever this error is observed persistently, power cycle the specified blade. If the problem - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 205
on internal Port S,P() with reason . Probable Cause Indicates that port is faulted due to port re-initialization failure. Recommended Whenever this error is observed persistently, power cycle the specified blade. If the problem Action - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 206
15 CDR-1019 Recommended Whenever this error occurs, restart the system at the next maintenance window. Action Severity WARNING 120 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 207
support the Advanced Performance Tuning module when the fibre connectivity (FICON) Management Server is enabled. Recommended Action Run the firmwareDownload command to upgrade the firmware on the standby CP. You can also disable FMS on the active CP. Severity ERROR Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 208
16 CER-1001 122 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 209
On a Brocade 24000 or 48000 switch, run the slotPowerOff command followed by the slotPowerOn command. On a Brocade 200E, 3250, 3850, 3900, 4012, 4016, 4018, 4020, 4024, 4100, 4900, 5000, 7500, or AP7600 switch, reboot or power cycle the switch. Severity ERROR Fabric OS Message Reference 123 53 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 210
24000 or 48000 switch, run the slotPowerOff command followed by the slotPowerOn command. On a Brocade 200E, 3250, 3850, 3900, 4012, 4016, 4018, 4020, 4024, 4100, 4900, 5000, 7500, or AP7600 switch, reboot or power cycle the switch. Severity ERROR 124 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 211
a new firmware version using the firmwareDownload command. Refer to the Fabric OS Command Reference Manual for more information on this command. Severity ERROR CNM-1003 Message , [CNM-1003], ,, WARNING, , Crypto device configuration between local switch - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 212
>,, INFO, , iSCSI service is on the switch. Probable Cause Indicates that the Crypto service is enabled or disabled on the switch. Recommended No action is required. . Recommended No action is required. Action Severity INFO 126 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 213
>]. Probable Cause Indicates the node join timeout. Recommended Take the peer node offline, rejoin the node to the Encryption Group (EG). Action Severity INFO Fabric OS Message Reference 127 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 214
Potential Cluster Split condition. Probable Cause Indicates the posting event of a Potential Cluster Split condition. Recommended No action is required. Action Severity INFO 128 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 215
-number>,, INFO, , Got JOIN REQUEST from un-recognized GL node [], configured GL node is []. Probable Cause Indicates a join request was received from an invalid Recommended No action is required. Action Severity INFO Fabric OS Message Reference 129 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 216
CNM-1021], ,, INFO, , Failed to sign the node authentication message, admission control might fail. Probable Cause Indicates that the Node Admission Control node. Recommended No action is required. Action Severity INFO 130 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 217
Node . Probable Cause Indicates that a version mismatch has occurred. Recommended Upgrade the firmware or delete the Node from the Encryption Group (EG). Action Severity INFO CNM-1027 . Recommended No action is required. Action Severity INFO Fabric OS Message Reference 131 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 218
errno . Probable Cause Indicates that an attempt to open the certificate file has failed. Recommended No action is required. Action Severity WARNING 132 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 219
Cause Indicates an event is being posted to indicate that the cluster is in a degraded state. Recommended No action is required. Action Severity WARNING Fabric OS Message Reference 133 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 220
!, Minority WWN/GL Node, remote_wwn:local_wwn . Probable Cause Indicates that split arbitration is lost. Recommended No action is required. Action Severity INFO 134 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 221
>, Updating persistent Cluster DB, please avoid powering off the switch. Probable Cause Indicates the system is updating configuration error. Probable Cause Indicates that the remote node's WWN might be changed. Recommended No action is required. Action Severity ERROR Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 222
[]. Probable Cause Indicates that the status of the network interface is UP or DOWN. Recommended No action is required. Action Severity INFO 136 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 223
Access Gateway Daemon mode mismatch, ensure mode settings are same across all nodes in EG. Probable Cause Indicates mode mismatch between the switches like the Access Gateway mode mismatch. Recommended No action is required. Action Severity ERROR Fabric OS Message Reference 137 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 224
EG with GL []. Probable Cause Indicates the node is rejoining the Encryption Group (EG). Recommended No action is required. Action Severity INFO 138 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 225
pair mismatch detected, re-initialize the node. Probable Cause Indicates that the certificate pair is mismatched. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 139 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 226
sequence-number>,, INFO, , IP of the switch changed from [] to []. Probable Cause Indicates that the switch IP has changed. Recommended No action is required. Recommended No action is required. Action Severity INFO 140 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 227
: success, Info: Membernode \\ left encryption group. Probable Cause Indicates the membernode left an encryption group. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 141 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 228
-name>, Event: cryptocfg Status: success, Info: registered. Probable Cause Indicates a membernode was registered. Recommended No action is required. Action Severity INFO 142 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 229
name if luns are setup for encryption. Recommended Preserve EG name when EG is recreated if luns are setup for encryption. Action Severity INFO Fabric OS Message Reference 143 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 230
18 CNM-3012 144 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 231
about the parameters and AD variable is the description of the classes of configuration parameters that were downloaded. If Admin Domain (AD) is enabled, the AD number is specified in and execute the Action configDownload command again. Severity INFO Fabric OS Message Reference 145 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 232
or more parameters that require the switch to be disabled. Recommended Disable the switch using the switchDisable command and download the configuration. Action Severity WARNING CONF-1023 Message Action configUpload command again. Severity INFO 146 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 233
key have not been applied. Recommended Action Use the configure command and various other commands to erase configuration parameters that are no longer required. As a last error and execute the Action configDefault command again. Severity INFO Fabric OS Message Reference 147 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 234
,, INFO, , Fabric Configuration Parameter changed to . Probable Cause Indicates that the fabric configuration parameter value has been changed. Recommended No action is required. Action Severity INFO 148 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 235
process for each pool. Recommended Do not start tape backup or restore operations involving tape pools until the process is complete. Action Severity INFO Fabric OS Message Reference 149 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 236
20 CTAP-1001 150 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 237
LUN ID: . Probable Cause Indicates the First time encryption, Key expired or Manual re-key operation is performed. The operation has been started, completed or cancelled. Recommended . Recommended No action is required. Action Severity INFO Fabric OS Message Reference 151 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 238
ID: . Indicates that there has been an attempt to remove the encryption LUN while decryption of existing data is still enabled. 152 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 239
is required for tape container: . Probable Cause Indicates that the tape container is configured with non-Brocade mode but there is no valid license. Recommended Obtain license for non-Brocade mode. Action Severity ERROR Fabric OS Message Reference 153 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 240
Probable Cause Indicates that the encryption LUN is configured with non-Brocade mode but there is no valid license. Recommended Obtain license for non-Brocade mode. Action Severity ERROR CVLC-1012 Message action is required. Action Severity ERROR 154 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 241
physical WWN>, LUN ID: . Probable Cause Indicates that the data state in the LUN configuration is in the encrypted state without a key ID and there is no metadata found on the LUN WWN>, LUN ID: . Indicates a warning or an error event. Fabric OS Message Reference 155 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 242
but metadata exists on the LUN. Recommended Use cryptocfg command to confirm the configuration. Action Severity ERROR CVLC-1020 Message , [CVLC-1020], - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 243
recommended on EE: . Probable Cause Indicates that due to container configuration changes, weights are not balanced on OB1s. Recommended Run cryptocfg --rebalance command that the device decommission process has either succeeded or failed. Fabric OS Message Reference 157 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 244
ID>. Probable Cause Indicates that the secondary metadata exists on the LUN that is not configured with --newLUN option. Recommended Use th ecryptocfg command to remove and add the LUN with Recommended No action is required. Action Severity ERROR 158 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 245
. Container: , Initiator: , LUN ID: . Probable Cause Indicates the manual rekey was completed on primary LUN. Recommended Action 1. Make the target ports of the mirror LUN offline to hosts. 2. Re-establish the mirror. 3. Once the mirror is in - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 246
physical WWN>, LUN ID: . Probable Cause Indicates the host I/Os to secondary metadata region. Recommended No action is required. Action Severity INFO >. Indicates the First time encryption, Key expired or Manual re-key operation failed. 160 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 247
>, Initiator: , LUN ID: . Probable Cause Indicates the Host Write on secondary Meta-data block region failed. Recommended Disable the initiator port. Action Severity WARNING Fabric OS Message Reference 161 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 248
21 CVLC-1041 162 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 249
firmware version using the firmwareDownload command. Refer to the Fabric OS Command Reference Manual for more information on this command. Severity ERROR CVLM-1003 Message , [CVLM-1003], ,, INFO, , Crypto device configuration has been committed by switch - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 250
the configuration in the cluster group using the cryptocfg --commit command. Refer to Action the Fabric OS Command Reference Manual for more information on this command. Severity WARNING CVLM-1005 Message , [CVLM-1005], ,, INFO, , Crypto service is - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 251
WWN> ) IO link is not configured. Probable Cause Indicates that the EE IO link IP address is not configured. Recommended Configure the EE IO link IP address. Action Severity WARNING No action is required. Action Severity INFO Fabric OS Message Reference 165 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 252
Status: success, Info: HA cluster deleted. Probable Cause Indicates an HA cluster was deleted. Recommended No action is required. Action Severity INFO 166 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 253
Probable Cause , [CVLM-3007], ,, INFO, , Event: cryptocfg Status: success, Info: container \\ created. Indicates a cryptotarget container was created. Fabric OS Message Reference 167 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 254
cryptocfg Status: success, Info: Manual failback from EE / to EE /. Probable Cause Indicates a manual failback was performed to an >\. Indicates an initiator was added to a cryptotarget container. 168 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 255
\\, in crypto target container \\ modified. Probable Cause Indicates a LUN in a cryptotarget container was modified. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 169 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 256
>, Event: cryptocfg Status: success, Info: Tape pool \\ deleted. Probable Cause Indicates a tapepool was deleted. Recommended No action is required. Action Severity INFO 170 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 257
system-name>, Event: cryptocfg Status: success, Info: Manual rekey all performed. Probable Cause Indicates a complete manual rekey was performed. Recommended No action is required. performed. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 171 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 258
, LUN ). Probable Cause Indicates that the decommission operation has failed for the device. Recommended Reissue the decommission command. Action Severity INFO 172 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 259
: success, Info: SRDF mode set to . Probable Cause Indicates that the SRDF mode was set. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 173 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 260
22 CVLM-3028 174 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 261
that 802.1X is enabled for the specified port. Recommended No action is required. Action Severity INFO DOT1-1004 Message Probable Cause , [DOT1-1004], ,, INFO, Port is forcefully unauthorized. Indicates that the port is unauthorized forcefully. Fabric OS - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 262
1006 Message , [DOT1-1006], ,, WARNING, 802.1X authentication has failed on port . Probable Cause Indicates that the authentication has failed on the specified port. Recommended Check the credentials configured with the Supplicant and RADIUS servers. Action - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 263
802.1X is disabled for port . Probable Cause Indicates that 802.1X is disabled for a specified port. Port is set in auto mode. Probable Cause Indicates that the port is set to auto mode. Recommended No action is required. Action Severity INFO Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 264
23 DOT1-1010 178 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 265
Chapter ECC System Messages 24 ECC-1000 Message , [ECC-1000], ,, ERROR, , ECC Error bit errors and all other error types should be reported to technical support for Action further action. Severity ERROR Fabric OS Message Reference 179 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 266
24 ECC-1001 180 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 267
range of the switch. Refer to the Hardware Reference Manual for the environmental temperature range of your switch. Execute the fanShow Action On Brocade 24000 and 48000, reseat the specified FRU. If the problem persists, restart or power cycle the switch. Fabric OS Message Reference 181 53 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 268
command to make sure that Power-On Self-Test (POST) is enabled; then power cycle the blade using the slotPowerOff and slotPowerOn commands or have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware problems. On the Brocade 24000 and 48000, replace the - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 269
with your control processor (CP) type and firmware. If the incompatibility is with the logical switch configuration, change the configuration using the lscfg command to be consistent with the blade type, or remove the blade. Severity CRITICAL Fabric OS Message Reference 183 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 270
the specified switch blade or nonbladed switch failed to transition from one state to another. It is faulted. The specific failed target state is displayed in the message. There are serious internal Fabric OS configuration or hardware problems on the switch. 184 Fabric OS Message Reference 53 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 271
(). Probable Cause Indicates that a problem was discovered when performing consistency checks during a warm boot. Recommended Monitor the switch. If the problem persists, restart or power cycle the switch. Action Severity WARNING Fabric OS Message Reference 185 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 272
faulted, it's an FCoE blade and the Ethernet switch service is not enabled. Please run . Indicates that a blade inserted in the specified slot requires the Ethernet switch service, which is not enabled. The blade is faulted. 186 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 273
only. This can indicate a significant hardware problem. The FRU ID value is composed of a FRU type string and an optional number to identify the unit, slot, or port. Recommended Action If the problem persists, restart or power cycle the switch. If the problem still persists, replace the WWN card - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 274
, or completely screw in the upper thumbscrew for the FC4-48 port blade) if the field-replaceable unit (FRU) is intended for use. Refer to the appropriate Hardware Refernce Manual for instructions on inserting the switch blades. Severity ERROR EM-1033 Message , [EM-1033], - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 275
-On Self-Test (POST) is enabled; then power cycle the blade using the slotPowerOff and slotPowerOn commands or have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware problems. If the problem still persists, replace the FRU. Severity WARNING EM-1037 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 276
Probable Cause Indicates that the specified field-replaceable unit (FRU) cannot be powered on because the associated logical switch is shut down. Recommended Execute the switchStart command on the associated logical switch. Action Severity WARNING 190 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 277
(CP256) is not supported on that chassis (backplane revision D2). Remove the blade from the chassis. If the error is due to switch configuration, the blade's logical switch configuration is not correct. Execute the lscfg command to correct the switch or port configuration for the ports on the blade - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 278
recovered: state Probable Cause Indicates that the Inter-Integrated Circuit (I2C) bus problems have been resolved and I2C access to the field-replaceable unit (FRU) has become available again as soon as possible. Action Severity INFO 192 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 279
[EM-1058], ,, WARNING, , Switch gets reset:. Probable Cause Indicates that the switch is being automatically reset because of a known resetable transient problem such as an application-specific integrated circuit (ASIC) parity error. Recommended Action - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 280
supported on this platform, check FOS firmware version as a possible cause. Probable Cause Indicates that a blade inserted in the specified slot or the switch (for nonbladed switches) is incompatible with the switch configuration not supported by the release on OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 281
Indicates the blade is being powered off because a hardware (HW) application-specific integrated circuit (ASIC) error was detected, and you have selected to power off the problem blade when such a condition occurred. Recommended Contact your switch service provider for assistance. Action Severity - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 282
Upgrade the Fabric OS firmware or the SAS firmware using the firmwareDownload command. Refer Action to the release notes for a compatible version of firmware. Severity WARNING EM-1066 Message , [EM-1066], ,, INFO, , SAS Virtualization Services are now - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 283
EM-1069 25 Recommended Action Restart or power cycle the switch. If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. Severity ERROR EM-1069 Message , [ - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 284
slotPowerOff and slotPowerOn commands or have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware problems. • On bladed systems, replace the specified FRU; otherwise replace the switch. Severity ERROR 198 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 285
Action Discontinue the firmware download, identify the downlevel switch or switches that do not support the Coordinated HotCode protocol, and upgrade the downlevel switches. Then, restart the firmware download on this switch. Note that upgrading a downlevel Brocade switch in a mixed interop - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 286
the Coordinated HotCode protocol, a switch in the fabric has rejected the data traffic disruption observed during the firmware download may have been due to configured (received from domain ). Probable Cause Indicates that the fabric name is configured OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 287
Duplicate Fabric Name - matching with FID . Probable Cause Indicates that the configured fabric name is already used for another partition. Recommended Select a different fabric name and reconfigure. Action Severity WARNING Fabric OS Message Reference 201 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 288
26 ESS-1010 202 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 289
FTP Action transfers; then run the supportSave command and contact your switch service provider. Severity ERROR ESW-1002 Message , [ESW-1002 Recommended On a Brocade 8000 switch, restart or power cycle the switch. Action Severity ERROR Fabric OS Message Reference 203 53-1002448- - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 290
recovery. Recommended On a Brocade 8000 switch, restart or power cycle the switch. Action Severity ERROR ESW- Switch port disabled due to \"\". Indicates that the switch port is disabled due to the reason displayed in the message. 204 Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 291
to make more buffers available for the link. Refer to the Fabric OS Administrator's Guide for more information. Severity WARNING ESW-1008 Message , [ESW-1008], ,, WARNING, , are port swapped on ports that do not support port swap. Slot - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 292
27 ESW-1008 206 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 293
through in-band. The event could not be sent to the remote proxy because the remote proxy switch cannot be reached through in-band. Recommended Please make sure that the specified remote domain is present in the fabric. Action Severity WARNING Fabric OS Message Reference 207 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 294
28 EVMD-1001 208 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 295
on the neighbor switch to view the error log for additional messages. Check for a faulty cable or deteriorated small form-factor pluggable (SFP). Replace the cable or SFP if necessary. Run the portLogDumpPort command on both the receiving and transmitting ports. Fabric OS Message Reference 209 53 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 296
switch service provider. Severity WARNING FABR-1004 Message , [FABR-1004], ,, WARNING, , port: - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 297
problem with the Fabric OS. Recommended Action In case of severe memory corruption, the system might recover by performing an automatic failover. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 298
from the error. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING 212 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 299
mode is set under the configure command or in Web Tools on the Switch Admin > Configure window. Severity ERROR FABR-1015 Message , [FABR-1015], ,, ERROR, , FICON Insistent DID max retry exceeded: All E-Ports will be disabled. Switch is isolated. Probable - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 300
name (WWN). Recommended Action Make sure that no other switch is configured as the principal switch. Force a fabric rebuild by using the switchDisable and switchEnable commands. Refer to the Fabric OS Command Reference for more information about the fabricPrincipal command. Severity WARNING 214 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 301
() exceeds supported configuration (). Probable Cause Indicates that this switch is a value-line switch and has exceeded the limited fabric size: that is, a specified limit to the number of domains. This limit is defined by your specific value-line license key - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 302
value is defined by your specific value-line license key. The fabric size has exceeded this specified limit. The grace-period timer has been initialized. If the grace period is complete and the size of the fabric is still outside the specified limit, Web Tools is disabled. Recommended Action Bring - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 303
. This is the Fibre Channel standard protocol, that uses R_RDY primitive for flow control. • DUAL_CR mode: Dual-credit flow control mode. In both of the previous modes, the buffer credits are fixed, based on the port configuration information. In this mode, the buffer credits are negotiated as part - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 304
to match with the same Master Trunk Area, or disable Trunk Area. You must manually enable the port or the port remains disabled forever. Refer to the Fabric OS Administrator's Guide for more information. Severity INFO FABR-1036 Message Probable Cause , [FABR-1036], - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 305
number>, INFO, , Port configuration incompatible with Trunk Area enabled port. Persistently disabling port . Probable Cause Indicates the specified port is being disabled because when the port attempts to go online, the Switch finds that Trunk Area enabled - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 306
. But no ports are disabled because the remote switch is not adjacent to the local switch. Recommended Make sure that all the switches in the fabric have the same Fabric ID or upgrade the switch Action firmware to a VF-capable firmware. Severity ERROR 220 Fabric OS Message Reference 53-1002448 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 307
. All the E_ports directly connected to the conflicting switch are disabled. Recommended Make sure that all the switches in the fabric have the same Base Switch attribute or upgrade the Action switch firmware to a VF-capable firmware. Severity ERROR Fabric OS Message Reference 221 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 308
is being disabled>. Probable Cause Indicates that there are no areas available to assign to the port during port creation. Recommended Move some ports out of the default switch to make areas available. Action Severity INFO FABR-1048 Message , [FABR-1048], ,, ERROR - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 309
An ASIC issue detected by remote loopback test failure. Recommended Replace the faulty SFPs, cables, or blade. Action Severity ERROR FABR-1052 Message , [FABR-1052], ,, INFO, , The configured port speed (16G/10G on non FC16 blade or 1G on FC16 blade) is - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 310
the port expand operation is still in progress and the standby CP has received a port update. The standby CP reboots automatically to ensure sync and attain normal state. This is a rare occurrence. Recommended No action is required. Action Severity INFO 224 Fabric OS Message Reference 53 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 311
OS problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware OS problem or file corruption. Recommended Reboot or power cycle the switch. Action Severity WARNING Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 312
- status=. Probable Cause Indicates that the Fabric OS has detected an invalid value in an object's status field. This is usually an internal Fabric OS problem or file corruption. Recommended Reboot or power cycle the switch. Action 226 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 313
Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. Severity state code was used in an internal Fabric OS message for a FRU. Fabric OS Message Reference 227 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 314
Reboot or power-cycle the CP or system. If the message persists, run the firmwareDownload command to update the firmware. Severity ERROR Fabric OS problem. Recommended Action Try removing and reinserting the FRU. Reboot or power-cycle the CP or system. 228 Fabric OS Message Reference 53- - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 315
FABS-1015 30 If the message persists, run the firmwareDownload command to update the firmware. Severity ERROR Fabric OS Message Reference 229 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 316
30 FABS-1015 230 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 317
Action The problem can be corrected by changing the version of firmware on the CP or AP blades. The firmware version on the CP blade can be changed using the firmwareDownload command. Refer to the release notes to determine whether a non-disruptive firmwareDownload is supported between the - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 318
31 FBC-1001 232 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 319
function> oid= Probable Cause Indicates that the hardware is not responding to a command request, possibly because it FIPS failure has occured and requires faulting the blade or switch. Recommended Retry the command. Action Severity CRITICAL FCIP- OS Message Reference 233 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 320
number>) port () tunnel (). Probable Cause Indicates that the FOS version on the remote end of the tunnel does not support Tape Read Pipelining. Recommended No action is required. Action Severity INFO 234 Fabric OS Message Reference 53-1002448 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 321
allocate new memory for an information unit (IU). Recommended A nonbladed switch will automatically reboot. For a bladed switch, the active CP blade will Action automatically fail over and the standby CP will become the active CP. Severity CRITICAL Fabric OS Message Reference 235 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 322
33 FCMC-1001 236 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 323
failed for . Probable Cause Indicates a memory failure. Recommended Check the switch memory status. Action Severity ERROR FCOE-1002 Message , [FCOE-1002], member from failed. Indicates that the logingroup has failed. Fabric OS Message Reference 237 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 324
, , Addition of nport mapping failed. Max nport mapping limit reached: . Indicates that the nport mapping has reached its maximum limit. 238 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 325
to add VLAN failed. Action Severity ERROR FCOE-1014 Message Probable Cause , [FCOE-1014], ,, ERROR, , Request to add ports to VLAN failed. Indicates that an add port request to VLAN has failed. Fabric OS Message Reference 239 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 326
VLAN. Severity ERROR FCOE-1018 Message Probable Cause , [FCOE-1018], ,, ERROR, , Request to delete MACs from Layer 2 for slot/port failed. Indicates a delete request for slot or port has failed. 240 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 327
FC-MAP has not been configured on FCOE VLAN. Recommended Configure FC-MAP on FCOE VLAN. Action Severity WARNING FCOE-1021 Message , [FCOE-1021], ,, INFO, , Port Cause Indicates that the switch has reached its OS Message Reference 241 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 328
FCF than base FLOGI. Probable Cause Indicates the base port has sent an FLOGI but the subsequent FDISCs that was received on the switch does not match the original FLOGI. Recommended It is after an FLOGI but the associated controller cannot be found. 242 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 329
will be printed. Recommended Change the FCoE login group policy on the switch for the device to login. Action Severity ERROR FCOE-1029 Message , FCoE port deleted port slot . Indicates that an FCoE port has been deleted. Fabric OS Message Reference 243 53-1002448 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 330
-number>,, WARNING, , Logingroup dropped for switch wwn: , due to name conflict while merging. Indicates that same logingroup name exists for two different switches that have different OUIs, but the same last three bytes. 244 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 331
created. Probable Cause Indicates that the logingroup is added in the switch logingroup table. Recommended No action is required. Action Severity INFO FCOE name>, Transaction aborted. Indicates that the ongoing configuration transaction is aborted. Fabric OS Message Reference 245 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 332
No action is required. Action Severity INFO FCOE-1045 Message Probable Cause , [FCOE-1045], ,, INFO, , FCoE port is configured as VEport. Indicates that the FCoE port is configured as VE port. 246 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 333
, [FCOE-1048], ,, INFO, , FCoE port is configured as VFport. Probable Cause Indicates that the FCoE port is configured as VF port. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 247 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 334
34 FCOE-1048 248 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 335
. Recommended Action The Brocade DCX, 4100, 4900, 5000, 7500, and AP 7600 do not support private loop devices. Refer to the switch vendor for a list of other port types that support private devices for inclusion into the fabric. Severity INFO Fabric OS Message Reference 249 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 336
35 FCPD-1003 250 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 337
WARNING, , Port has been disabled since switch requires authentication when device authentication policy is set to ON. Probable Cause Indicates a device which does not support authentication has tried to log in to the switch when the device authentication policy is in ON - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 338
conditions, the buffer used for quick memory allocations (known as atomic malloc) can be quickly depeleted and not replenished before the next allocation occurs. Recommended Reset the affected port indicated in the message. Action Severity WARNING 252 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 339
-1004 Message Probable Cause , [FCR-1004], ,, INFO, , FC router physical devices offline at port . Indicates that one or more physical devices connected to the specified port have gone offline. Fabric OS Message Reference 253 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 340
SFPs, or dirty connections. Replace the cables and SFPs if necessary. Severity INFO FCR-1005 Message , [FCR-1005], ,, INFO, , FC router LSAN zone device removed at port - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 341
port. The enabled LSAN zone configuration is listed. Recommended No action is required. Action Severity INFO FCR-1010 Message , [FCR-1010], ,, INFO, , FC router LSAN zone disabled at port - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 342
FC Router fabric build completed on port . Probable Cause Indicates that the fibre channel router has completed a fabric build at the specified port INFO, , New EX_Port or VEX_Port added on port in domain . Probable Cause Indicates that an - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 343
switch failure. Recommended No action is required. Action Severity INFO FCR-1018 Message , [FCR-1018], ,, ERROR, , FC router proxy device entries exhausted on port - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 344
, [FCR-1020], ,, WARNING, , Local LSAN zone entries for FC router exhausted; max limit: . Probable Cause Indicates that the number of logical area network (LSAN) zone entries. Severity ERROR 258 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 345
the number of proxy devices for a translate domain (which limits the number of translate domain ports required) by limiting the devices specified in logical storage area network (LSAN) zones. Severity detected to not be in use are reused as needed. Fabric OS Message Reference 259 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 346
port world wide name (WWN) pool has rolled over in the specified slot, and WWN entries detected to not be in use are reused as needed. Recommended Action It is unlikely that WWN conflicts will occur as a result of pool rollover unless the switch INFO 260 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 347
. Probable Cause Indicates that the Port world wide name (WWN) pool has rolled over in the specified slot, and WWN entries detected not in use are reused as needed. Recommended Action It is unlikely that WWN conflicts will occur as a result of pool rollover unless the switch is deployed in a very - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 348
FCR-1033], ,, INFO, , Edge fabric disabled security on port in fabric . Probable Cause Indicates that Secure mode was turned the backbone fabric. The enabled LSAN zone configuration is listed. 262 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 349
number of cfg/zone/alias entries created in a local fabric is greater than the local switch&apos zone database limitations. Recommended Remove excess cfg/zone/alias entries so that the number of local LSAN zone database limitations. Severity INFO Fabric OS Message Reference 263 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 350
the backbone fabric. Probable Cause Indicates that a proxy device was created in the backbone fabric. Recommended No action is required. Action Severity INFO 264 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 351
link protocol (ELP) command was issued and it is not supported. Recommended Action Run the portEnable and portDisable commands to enable and disable the port. If the problem persists contact your switch service provider. Severity ERROR FCR-1053 Message , [FCR-1053], - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 352
the switch with Action one that supports backbone to edge routing. Severity INFO FCR-1057 Message , [FCR-1057], ,, ERROR, , EX_Port() incompatible long distance parameters on link. Probable Cause Indicates that the port, which is configured - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 353
to restart authentication. Severity INFO FCR-1060 Message , [FCR-1060], ,, WARNING, , EX_Port() has an incompatible configuration setting. Probable Cause Indicates that virtual channel (VC) Link Init is enabled on the local switch and the - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 354
Fibre Channel standard protocol, that uses R_RDY primitive for flow control. Severity WARNING FCR-1061 Message , [FCR-1061], ,, INFO, , Backbone fabric created on port - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 355
zones and aliases, exceeded on port by entries; max entries: . Indicates that the total number of zone configurations created in the connected fabric exceeds the maximum number supported by the Fibre Channel. Fabric OS Message Reference 269 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 356
set to 1 (enabled). Note that the FC Routing service is disabled by the factory. Recommended No action is required. Action Severity INFO FCR-1070 Message , [FCR-1070], ,, INFO, , The FC Routing configuration is set to default. Probable Cause Indicates - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 357
an earlier version of the switch in the backbone or edge that supports a different limit of logical storage area network (LSAN) zones was detected. Recommended Action Use the fcrResourceShow command on all Fibre Channel Routers in the Meta-SAN to find the lowest supported LSAN zone limits. Ensure - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 358
port . Probable Cause Indicates that the zone name configuration size created in the connected fabric exceeds the maximum supported by the FC when the binding list details configured on the M-Model switch does not match with the currently configured front port domain ID and WWN of - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 359
Recommended Ensure that the M-Model switch has the same currently configured details such as front port Action domain ID and WWN firmware download may have been due to the result of the rejected pause message. Recommended No action is required. Action Severity WARNING Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 360
that during the Coordinated HotCode protocol, a switch in the fabric did not accept the resume message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been due to this issue. 274 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 361
Indicates that the remote control processor (CP) has older firmware, which does not support Condor-based EX_ port. This is causing the loss of the high-availability ( use XISL' mode of the domain by using the configure command. Action Severity ERROR Fabric OS Message Reference 275 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 362
-name>, FCR ELS trap entries exhausted. Probable Cause Indicates that the FCR ELS trap entries are exhausted. Recommended Collect supportsave data and send it to support. Action Severity ERROR 276 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 363
Indicates that an EX-port has been configured in Brocade Native mode. Device sharing will not happen with other Brocade Native mode fabrics because Integrated Routing license is not installed. Recommended No action is required. Action Severity WARNING Fabric OS Message Reference 277 53-1002448 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 364
37 FCR-1094 278 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 365
a 1 byte hexidecimal value that represents the domain of the switch that the FICON Channel is directly connected to. • HP - Host Port number: This is a 1 byte hexidecimal value that represents the switch port of the switch that the FICON Channel is directly connected to. • DD - Device Domain number - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 366
Disabled>. Probable Cause Indicates that the FICON configuration was changed manually. Recommended No action is required. Action Emulation Enabled or Disabled>. Probable Cause Indicates that the Fibre Channel over IP (FCIP) Tunnel ID associated with the FICON OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 367
that were received from the device>. Probable Cause Indicates that a Selective Reset from the channel was received as normal part of path recovery or starting sequence in with this event, contact your switch service provider. Action Severity INFO Fabric OS Message Reference 281 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 368
received from the FICON channel. Recommended If there was a job or IO failure associated with this event, contact your switch service provider. Action Severity associated with this event, contact your switch service provider. Action Severity ERROR 282 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 369
was a job or IO failure associated with this event, contact your switch service provider. Action Severity INFO FICN-1014 Message , [FICN-1014], components. Recommended Contact your switch service provider. Action Severity ERROR Fabric OS Message Reference 283 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 370
with a FICON Control Unit CUADDR. Recommended Contact your switch service provider. Action Severity ERROR FICN-1019 Message Probable Cause FICON channel indicated in the path issued an Link Level Reject (LRJ) frame for a sequence from the device. 284 Fabric OS Message Reference 53-1002448 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 371
Cause Indicates that the FICON channel issued a Selective Reset for a device that was active in emulation. Recommended If there was an unexpected job failure associated with this event, contact your switch service Action provider. Severity ERROR Fabric OS Message Reference 285 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 372
FICON channel issued a Selective Reset sequence for a device. Recommended If there was an unexpected job failure associated with this event, contact your switch service Action tape write pipeline is completing an emulated Selective Reset sequence. 286 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 373
Indicates that an active disk emulation device received a Selective Reset from the FICON channel. Recommended If there was an unexpected job failure or IO Error associated with this event, contact your switch Action service provider. Severity ERROR Fabric OS Message Reference 287 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 374
Purge Path from the channel. Recommended If there was an unexpected job failure or IO Error associated with this event, contact your switch Action service provider. Severity ERROR a logical path establishment command sequence with the FICON channel. 288 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 375
received a frame with an invalid FICON LRC from the peer. This indicates that the channel side noted corruption from the device or CU processing. Recommended Contact your switch service provider. Action Severity ERROR FICN-1035 Message , [FICN-1035], ,, WARNING - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 376
HostPort DeviceDomain> . Probable Cause Indicates that a locally connected FICON channel sent a frame that could not be associated with a FICON Control Unit. Recommended Contact your switch service provider. Action Severity ERROR 290 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 377
from the channel. Recommended If there was an unexpected job failure or IO Error associated with this event, contact your switch Action service provider. Severity event), contact your vendor's Action customer support for assistance. Severity WARNING Fabric OS Message Reference 291 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 378
name>, HostTapeIng::FICON Selective Reset:Path= - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 379
presented to the channel for this device> treating as system reset event. Probable Cause Indicates an LRJ from a FICON channel indicates that the channel believes that it contact your vendor's customer support for assistance. Action Severity WARNING Fabric OS Message Reference 293 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 380
This is an unexpected event; contact your vendor's customer support for assistance. Action Severity WARNING FICN-1050 Message . Probable Cause Indicates a TIR received Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 381
extended DASD device. Recommended If this was an unexpected event, contact your vendor's customer support for assistance. Action Severity INFO FICN-1053 Message , [FICN-1053], - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 382
device. Recommended This is an unexpected event, contact your vendor's customer support for assistance. Action Severity ERROR FICN-1058 Message , [FICN-1058 contact your vendor's customer support for assistance. Action Severity ERROR 296 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 383
LPAR. Recommended This is an unexpected event, contact your vendor's customer support for assistance. Action Severity ERROR FICN-1060 Message , [FICN-1060 , contact your vendor's customer support for assistance. Action Severity ERROR Fabric OS Message Reference 297 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 384
Indicates an abort operation has been received from a local FC interface for an exchange. Recommended If there were associated IO errors at the same time as this event, contact your vendor's customer Action support for assistance. Severity INFO 298 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 385
use Action or there is an internal memory leak, contact your vendor's customer support for assistance. Severity WARNING FICN-1067 Message , [FICN-1067], - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 386
noted in the FICON configuration. Refer to the string for the nature of the configuration issue. Recommended If resolution of the configuration issue cannot be completed, contact your vendor's customer Action support is required. Action Severity INFO 300 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 387
emulation states>:cmds=0x:status=0x:flags=0x - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 388
channel for this device>:flags=0x. Indicates a Rewind and Unload IO has been processed from a remotely connected LPAR, which indicates that a tape should be unloaded on a device. 302 Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 389
processed from a remotely connected LPAR and Read Block pipelining was performed on the currently loaded tape. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 303 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 390
connected LPAR and Read Channel Program pipelining was port which had a FICON emulated path established has logged out from the switch. Recommended This may be an unexpected event, contact your vendor's customer support for assistance. Action Severity WARNING 304 Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 391
GE1>,tunnel Id=. Probable Cause Indicates a FICON FCIP tunnel to the peer switch has been terminated. Recommended This is an unexpected event, contact your vendor's customer support for assistance. Action Severity ERROR Fabric OS Message Reference 305 53-1002448 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 392
Cause Indicates the FICON channel issued a Cancel sequence for a device in emulation. Recommended If there was an unexpected job failure associated with this event, contact your vendor's customer Action support for assistance. Severity WARNING 306 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 393
received the selective reset> statArray=0x< channel issued a Purge Path command sequence for a device. Recommended If there was an unexpected job failure or IO Error associated with this event, contact your vendor's Action customer support for assistance. Severity ERROR Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 394
Cause Indicates the FICON tera write pipeline is completing an emulated Selective Reset sequence. Recommended If there was an unexpected job failure or IO with this event, contact your vendor's Action customer support for assistance. Severity ERROR 308 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 395
DevicePort LPAR CUADDR DeviceAddr> LastCmds=0x SenseData:Bytes0-0xB=0x - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 396
-name>, HostTeraIng::FICON Selective Reset:Path=0x - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 397
reset event. Probable Cause Indicates an LRJ from a FICON channel indicates that the channel believes that it no longer has a path established to the CU. Recommended This is normally an unexpected event; contact your vendor's customer support INFO Fabric OS Message Reference 311 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 398
Cause Indicates the FICON channel issued a Cancel sequence for a device in emulation. Recommended If there was an unexpected job failure associated with this event, contact your vendor's customer Action support for assistance. Severity WARNING 312 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 399
. Probable Cause Indicates the FICON channel issued a Selective Reset sequence for a device. Recommended If there was an unexpected job failure associated with this event, contact your vendor's customer Action support for assistance. Severity ERROR Fabric OS Message Reference 313 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 400
Cause Indicates an LRJ from a FICON channel indicates that the channel does not have a path established to the CU. Recommended This is normally an unexpected event, contact your vendor's customer support for assistance. Action Severity WARNING 314 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 401
> LastCmds=0x SenseData:Bytes0-0xB=0x - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 402
this device> seconds. Probable Cause Indicates that the channel recognized a timeout condition and issued a Selective Reset. Recommended If this was an unexpected event, contact your vendor's customer support for assistance. Action Severity ERROR 316 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 403
to the channel for this device> treating as system reset event. Probable Cause Indicates than an LRJ was received from a FICON channel indicates that the channel believes that your vendor's Action customer support for assistance. Severity INFO Fabric OS Message Reference 317 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 404
Indicates an abort operation has been received from a local FC interface for an exchange. Recommended If there were associated IO errors at the same time as this event, contact your vendor's customer Action support for assistance. Severity INFO 318 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 405
-number>,, WARNING, , EmulEls:SW_RSCN received on VEPort= Domain=0x Port=0x. Indicates an attached port with the established FICON emulated path has logged out from the switch. Fabric OS Message Reference 319 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 406
Emulation Enabled FCIP tunnel to the peer switch has been terminated. Recommended This is an unexpected event, contact your vendor's customer support for assistance. Action Severity ERROR FICN- Action (mode 0) or Aggressive (mode 3). Severity ERROR 320 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 407
functions have failed. The key variable is a part of the Fabric OS configuration database and is for support use only. The error variable is an internal error number. Recommended Action Execute the haFailover command on the switch if it has redundant control processors (CPs) or restart the - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 408
Cause Indicates that the logical path with the specified PID and channel image ID lost allegiance to a FICON-CUP device. Recommended Check if the FICON channel corresponding to the PID in the message is functioning properly. Action Severity WARNING 322 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 409
the supportSave command and contact your switch service provider. Severity WARNING FICU-1008 Message , [FICU-1008], ,, WARNING, , FMS mode has been enabled. Ports: have been disabled due to port address conflict. Probable Cause Indicates - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 410
, [FICU-1013], ,, WARNING, , Host data file cannot be resetted to proper size. Probable Cause Indicates that the file system is full to create a host data reserved areas 0xFE and 0xFF are bound to a device. 324 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 411
to areas. Action Execute wwnaddress --unbind [WWN] command to release the reserved area from the device. Severity WARNING FICU-1018 port address and port number relationship. Action Severity WARNING FICU-1019 Message , [FICU-1019], ,, INFO, , Switch - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 412
, [FICU-1024], ,, ERROR, , Detected 64 port blade when FMS mode is enabled. Probable Cause Indicates presence of a 64-port blade in the switch. Recommended No action is required. Action Severity ERROR 326 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 413
. When the FC kernel driver reuses the exchange, the application will overlap. This happens on a timed-out exchange; it automatically recovers after the application times the exchange out. Recommended No action is required. Action Severity WARNING Fabric OS Message Reference 327 53-1002448 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 414
40 FKLB-1001 328 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 415
LSU length = Probable Cause Indicates that the LSU size exceeds what the system can support. Recommended Reduce the number of switches in the fabric or reduce the number of redundant ISLs between two Action switches. Severity ERROR Fabric OS Message Reference 329 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 416
Indicates that the transmit LSR contained an invalid domain number. Recommended No action is required because the LSR is discarded. Action Severity WARNING 330 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 417
Message , [FSPF-1001], ,, ERROR, , Input Port out of range Probable Cause Indicates that the specified input port number is out of range as it does not exist on the switch. Recommended No action is required. Action Severity ERROR FSPF-1002 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 418
fabric. SilkWorm switches support only section ID supported on the specified input port. Recommended Update the FSPF version by running the firmwareDownload command to update the firmware to the Action latest version. All current versions of the Fabric OS support domains using ICL or regular - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 419
-number>,, INFO, , ICL Topology is valid on local domain . Probable Cause Indicates that the current ICL topology is valid for routing from the local switch. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 333 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 420
42 FSPF-1010 334 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 421
the problem persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service command. For nonbladed systems, restart the switch using the reBoot command. Fabric OS Message Reference 335 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 422
available on the FSS device. Recommended If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP Action transfers; then execute the supportSave command and contact your switch service provider. Severity WARNING 336 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 423
Execute the supportShow or supportSave commands to validate the network configuration and then execute the haSyncStart command to restore the HA synchronization. If the problem persists, contact your switch service provider. Severity CRITICAL FSS-1008 Message , [FSS-1008], - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 424
43 FSS-1011 Recommended Execute the supportSave command and contact your switch service provider. Action Severity WARNING FSS-1011 Message , [FSS-1011], - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 425
, execute the haDump command to diagnose the problem. If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. WARNING FSSM-1004 Message Probable Cause - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 426
is not compatiable with the current running version. This causes a disruptive firmware upgrade or downgrade. Recommended For a dual CP system, execute the firmwareDownload command to load compatible firmware on the Action standby CP. Severity INFO 340 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 427
range of the switch. Refer to the hardware reference manual for the environmental temperature range of your switch. Severity WARNING that the internal temperature of the switch has risen above the high boundary to a value that might damage the switch. Fabric OS Message Reference 341 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 428
of the switch has power supply is not producing enough power. Recommended Verify that you have installed the power supply correctly and that it is correctly seated in the Action chassis. If the problem persists, replace the faulty power supply. Severity WARNING 342 Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 429
Low value>). Current value is . Probable Cause Indicates that the power supply counter changed from a value outside of the acceptable range to a value of the small form-factor pluggable (SFP) has fallen below the low boundary. Fabric OS Message Reference 343 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 430
if the SFP is in good working condition or not. If the counter often exceeds the threshold, the SFP is deteriorating. Recommended Incoming laser fluctuations usually indicate a deteriorating SFP. If the message persists, replace Action the SFP. Severity INFO 344 Fabric OS Message Reference 53 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 431
that the receive power value of the small form-factor pluggable (SFP) has fallen below SFP is deteriorating. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 432
Indicates that the transmit power value of the small form-factor pluggable (SFP) has risen above the SFP is in good working condition or not. If the counter often exceeds the threshold, the SFP is deteriorating. Recommended Replace the SFP. Action Severity WARNING 346 Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 433
form-factor pluggable (SFP) voltage has fallen below the low boundary. Recommended Verify that your optical components are clean and function properly. Replace deteriorating cables Action or SFPs. Check for damage from heat or age. Severity WARNING Fabric OS Message Reference 347 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 434
SFP) voltage has risen above the high boundary. Recommended The supplied current of the SFP transceiver is outside of the normal range, indicating possible Action hardware small form-factor pluggable (SFP) voltage has fallen below the low boundary. 348 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 435
the low boundary. Recommended Configure the low threshold to 1 so that the threshold triggers an alarm when the value falls to 0 Action (Out_of_Range). If continuous or repeated alarms occur, replace the SFP before it deteriorates. Severity WARNING Fabric OS Message Reference 349 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 436
transient errors. A low number of E_Port failures means that the switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO 350 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 437
following occurrences can cause a fabric reconfiguration: • Two switches with the same domain ID have connected to one SFPs) have not become faulty. An inexplicable fabric reconfiguration might be a transient error and might not require troubleshooting. Severity INFO Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 438
The following occurrences can cause a fabric reconfiguration: • Two switches with the same domain ID have connected to one another. SFP) has not become faulty. An inexplicable fabric reconfiguration might be a transient error and might not require troubleshooting OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 439
ID changes has risen above the high boundary. Domain ID changes occur when there is a conflict of domain IDs in a single fabric and the principal switch has to assign another domain ID to the switch. Fabric OS Message Reference 353 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 440
• Segmentation of the principal link between two switches. • Incompatible link parameters. During E_Port initialization, ports exchange link parameters. Rarely, incompatible parameters result in occur due to the following reasons: • Zone conflicts. 354 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 441
: • Zone conflicts. • Domain conflicts. • Segmentation of the principal link between two switches. • Incompatible link parameters. During E_Port initialization, ports exchange link parameters. Rarely, incompatible parameters result in segmentation. Fabric OS Message Reference 355 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 442
is a change to the effective zone configuration. Recommended No action is required. Respond to the effective zone configuration. A low number of zone configuration changes means that the fabric there is a change to the effective zone configuration. Recommended No action is required. Respond to - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 443
the acceptable range. Zone changes occur when there is a change to the effective zone configuration. Recommended No action is required. Respond to this message as is appropriate to the particular of the Action end-user installation. Severity INFO Fabric OS Message Reference 357 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 444
pluggable (SFP) state changes has changed. SFP state changes occur when the SFP is inserted or removed. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO 358 Fabric OS Message Reference 53 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 445
value within the acceptable range. SFP state changes occur when the SFP is inserted or removed. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO Fabric OS Message Reference 359 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 446
of synchronization. Check for concurrent loss of synchronization errors and, if applicable, troubleshoot them. Recommended Check both ends of your cable connection. Verify that the cable and small form-factor pluggables Action (SFPs) are not faulty. 360 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 447
pluggables (SFPs) are not faulty. If you continue to experience synchronization loss errors, troubleshoot your host bus adaptor (HBA) and contact your switch service provider. Severity INFO FW-1165 Message Probable Cause , [FW-1165], ,, INFO, , - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 448
Port port SFP SFPs) are not faulty. If you continue to experience loss-of-synchronization errors, troubleshoot your host bus adaptor (HBA) and contact your switch service provider. Severity WARNING FW-1167 Message , [FW-1167], ,, INFO, , - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 449
(SFPs) are not faulty. Severity INFO FW-1169 Message , [FW-1169], ,, INFO, , - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 450
number of protocol errors that the port experiences has fallen below the low boundary. Occasional protocol errors occur due to software glitches. Persistent protocol errors occur due to hardware problems. A low number of protocol errors means that the switch is functioning normally. Recommended No - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 451
that the number of invalid words that the port experiences has fallen below the low boundary. Invalid words usually indicate a hardware problem with an small form-factor pluggable (SFP) or cable. A low number of invalid words means that the switch is functioning normally. Recommended No action is - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 452
. Probable Cause Indicates that the number of invalid words that the port experiences has risen above the high boundary. Invalid words usually indicate a hardware problem with an small form-factor pluggable (SFP) or cable. Recommended Verify that both ends of the connections, that - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 453
(CRC) that the port experiences has fallen below the low boundary. A low number of invalid CRCs means that the switch is functioning normally. pluggables (SFP), cables, and connections for faulty hardware. Verify that all optical hardware is clean. Severity INFO Fabric OS Message Reference 367 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 454
traffic that the port experiences has changed. , , , , is traffic that the port experiences has fallen , , , , is traffic that the port experiences has risen INFO, , , , is the port experiences has changed from - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 455
. Probable Cause Indicates that the percentage of outgoing traffic that the port experiences has changed. Recommended No action is required. Respond to this message as is appropriate the Action end-user installation. Severity WARNING Fabric OS Message Reference 369 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 456
the port experiences system-name>, , , , < port. A low number of port state changes means that the switch - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 457
experiences has changed. Link resets occur due to link timeout errors that indicate no frame activity. Recommended Check both ends of your cable connection. Verify if the cable and small form-factor pluggables Action (SFPs) are faulty. Severity INFO Fabric OS Message Reference 371 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 458
and hardware problems can cause link resets to increase. Recommended Check both ends of your cable connection. Verify if the cable and small form-factor pluggables Action (SFPs) are faulty. Severity WARNING FW-1199 Message , [FW-1199], ,, INFO, , - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 459
, , , -number>,, INFO, , , , is below low time out means that the switch is functioning normally. Recommended WARNING, , , , is above -number>,, INFO, , , , is between high - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 460
Action Severity INFO FW-1204 Message , [FW-1204], ,, INFO, , , , value has changed(High=, Low=). Current value is links to the trunk. Action Severity WARNING 374 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 461
appear due to the number of word frames that travel from the configured S_ID to the D_ID pair. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO Fabric OS Message Reference 375 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 462
end (EE) word frames that the switch receives has changed from a value outside configured S_ID to the D_ID pair. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO 376 Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 463
appear due to the number of word frames that travel from the configured S_ID to the D_ID pair. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO Fabric OS Message Reference 377 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 464
. Probable Cause Indicates that the number of frame types or commands that the port receives has changed. The port has received small computer system interface (SCSI) Read, SCSI Write, SCSI Read and end-user installation. Severity INFO 378 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 465
the IP address that sent the request. Responses to security-class messages depend on user policies. Consult your security administrator for Telnet connections to switches in the fabric. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 379 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 466
) addresses that are authorized to establish Telnet connections to switches in the fabric. Recommended Action Run the errShow command to class messages depend on user policies. Consult your security administrator for response strategies and policies. Severity INFO 380 Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 467
the IP address that sent the request. Responses to security-class messages depend on user policies. Consult your security administrator for browser connections to the switches in the fabric. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 381 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 468
request. Responses to security-class messages depend on user switch tried to join the fabric. The SCC_POLICY contains a list of switches by World Wide Names (WWNs) that are allowed to be members of a fabric. Recommended No action is required. Action Severity INFO 382 Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 469
that the number of switch connection control (SCC) switch tried to join the fabric. The SCC_POLICY contains a list of switches specification of rules for binding device ports (typically host bus adaptor (HBA) ports) to specific switch ports switch WWN, and switch port. Responses to security-class - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 470
specification of rules for binding device ports (typically host bus adaptor (HBA) ports) to specific switch ports specification of rules for binding device ports (typically host bus adaptor (HBA) ports) to specific switch ports WWN, switch WWN, and switch port. Responses to security-class messages - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 471
allows for the specification of rules for binding device ports (typically host bus adaptor (HBA) ports) to specific switch ports. DCC policies location of the login attempt. Responses to security-class messages depend on user policies. Consult your security OS Message Reference 385 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 472
this signature with the public key of the primary FCS switch. If verification fails, it rejects the packet. This counter keeps track of the number of packets received with invalid signatures. Recommended No action is required. Action Severity INFO 386 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 473
fabric. The receiving switch has to verify that the sender is the primary FCS switch and its certificate is signed by the Root CA recognized by the receiving switch. This counter keeps track of the number of packets received with invalid certificates. Fabric OS Message Reference 387 53-1002448 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 474
is the primary FCS switch and its certificate is signed by the Root CA recognized by the receiving switch. This counter keeps track of the number of packets received with invalid certificates. Recommended No action is required. Action Severity INFO 388 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 475
The switch on the other side might not support the protocol, have an invalid certificate, not be signed properly, or send unexpected packets. The port where authentication fails is segmented. This counter keeps track of the number of authentication failures. Recommended Responses to security-class - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 476
a value within the acceptable range. Authentication failures can occur for many reasons. The switch on the other side might not support the protocol, have an invalid certificate, not be signed properly or send unexpected packets. The port where authentication fails is segmented. This counter keeps - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 477
it increments this counter and resets the WWN of the primary FCS to all zeroes. Recommended Responses to security-class messages depend on user policies. Consult your security administrator Action for response strategies and policies. Severity INFO Fabric OS Message Reference 391 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 478
World Wide Name (WWN) of that primary FCS switch. If a secure switch finds that there are no FCSs in the fabric, but it still has the WWN of the last primary FCS switch, it increments this counter and resets the WWN of the primary FCS to all zeroes. 392 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 479
detected. When a switch is in secure mode, it connects only to another switch that is in secure mode and has a compatible security database. A compatible security database means that the version stamp and fabric configuration server (FCS) policy matches exactly. Fabric OS Message Reference 393 53 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 480
time someone issues one of these commands on a switch where it is not allowed. Recommended Responses to security-class messages depend on user policies. Consult your security administrator Action for response strategies and policies. Severity INFO 394 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 481
commands that can be executed only on the primary FCS switch as well as one security command that can be executed only on a backup FCS switch. The counter increments every time someone issues one of these commands on a switch where it is not allowed. Fabric OS Message Reference 395 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 482
operation of the switch. Excessive permanent increases can lead to future problems. Recommended No action operation of the switch. Excessive permanent increases can lead to future problems. Recommended No action of the switch. Excessive permanent increases can lead to future problems. Recommended - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 483
above high boundary(High=, Low=). Current value is . Indicates that the memory usage is above high memory threshold. Fabric OS Message Reference 397 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 484
to . Probable Cause Indicates that the switch status is not in a healthy state. This occurred because of a policy violation. Recommended Execute the switchStatusShow command to determine the policy violation. Action Severity WARNING 398 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 485
contributing factor Power supply: absent. Indicates that the switch status is not in a healthy state. This occurred because the number of missing power supplies is greater than or equal to the policy set by the switchStatusPolicySet command. Fabric OS Message Reference 399 53 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 486
name>, Switch status change contributing factor: Power supplies are not redundant. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the power supplies replaceable units (FRUs). Action Severity WARNING 400 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 487
greater than or equal to the policy set by the switchStatusPolicySet command. The CPs are non-redundant. If you power cycle a Brocade 24000 chassis in dual-domain configuration, and then reset the micro-switch of the active CP before the heartbeat is up, this will cause both CPs to come up in a non - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 488
to the policy set by the switchStatusPolicySet command. A port is considered faulty due to hardware failure such as a faulty small form-factor pluggable (SFP) or port. Recommended Replace any faulty or deteriorating SFPs. Action Severity WARNING 402 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 489
Switch status change contributing factor Missing SFPs: missing out of SFPs:config( percent,). (Port(s) - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 490
Cause Indicates that the state of the specified field-replaceable unit (FRU) has changed to faulty. Recommended Replace the FRU. Action Severity WARNING 404 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 491
redundancy, but the user has previously overridden the Switch Status Policy values pertaining to number of power supplies. So those values will not be automatically changed. With no AP blades, the default values are 3 (out of service) indicating switch status is DOWN or 0 indicating no checking for - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 492
[FW-1448], ,, WARNING, , Switch status change contributing factor Error ports: Error out of ports:config( percent,). (Port(s) ). Probable Cause Indicates that the - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 493
errors occur due to software glitches. Persistent errors occur due to hardware problems. Recommended Check for concurrent loss of synchronization errors. Check the SFP and the cable. Then, enable the Action port using the portEnable command. Severity WARNING FW-1511 Message , [FW - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 494
a loss of signal and fails. Both physical and hardware problems can cause link loss errors. Link loss errors frequently occur due to a loss of synchronization. Check for concurrent loss of synchronization errors and, if applicable, troubleshoot them. Recommended No action is required. Respond to - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 495
occur due to software glitches. Persistent protocol errors occur due to hardware problems. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO Fabric OS Message Reference 409 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 496
that the number of invalid words that the port experiences has changed and dropped below upper threshold boundary to a value within the acceptable range. Invalid words usually indicate a hardware problem with a small form-factor pluggable (SFP) or cable. Recommended No action is required. Respond - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 497
SFP), cables, and connections for faulty hardware. Verify that all optical hardware is clean. Severity INFO FW-1522 Message , [FW-1522], ,, INFO, , - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 498
Severity INFO FW-1526 Message , [FW-1526], ,, INFO, , , , has dropped below upper threshold boundary to in between(High=, Low=< the Action end-user installation. Severity INFO 412 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 499
of link resets that the port experiences has changed and crossed lower threshold boundary to a value within the acceptable range. Link resets occur due to link timeout errors that indicate no frame activity at all. Both physical and hardware problems can cause link resets to increase. Recommended - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 500
number of link resets that the port experiences has changed and dropped below upper threshold boundary to a value within the acceptable range. Link resets occur due to link timeout errors that indicate no frame activity at all. Both physical and hardware problems can cause link resets to increase - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 501
String> loss area in class since FOS6.3. Disabling port fencing feature for this. Probable Cause Indicates that in previous versions portfencing is configured for Link/Sync loss, but after upgrading to new version, in which portfencing is not suppoted, resets the above bit. Recommended - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 502
INFO FW-3011 Message , [FW-3011], ,, INFO, , , is below low boundary(High=, Low=). Current value is < Recommended No action is required. Action Severity INFO 416 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 503
INFO, , , value has changed ,, INFO, , , is below low boundary(High number>,, WARNING, , , is above high boundary( -number>,, INFO, , , is between high and low - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 504
Severity INFO FW-3018 Message , [FW-3018], ,, INFO, , , value has changed(High=, Low=). Current value is No action is required. Action Severity WARNING 418 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 505
number>,, WARNING, , , is below low boundary( supported. Probable Cause Indicates that the timebase for the class is changed to minute implcitly as seconds timebase is not supported. Recommended No action is required. Action Severity INFO Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 506
45 FW-3022 420 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 507
Monitor, with the specified device and Log="YES" Class="NONE" Severity level. The Severity variable can be hardware errors, software errors, compact flash errors, or memory errors. The Reboot Reason variable can be any of the following: • Hafailover • Reset • Fastboot Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 508
. The active CP will run a diagnostic test on the EMAC and will wait for the standby CP to reset if it is down. Recommended No action is required. Action Severity INFO HAM-1006 Message Probable Cause , test run by the HAM module. 422 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 509
auto-reboot is disabled. Indicates that the recovery by auto-restart is disabled, therefore the switch needs to be manually restarted for recovery. This message is displayed if the event logged in HAM-1007 has occurred and auto-reboot is disabled. Fabric OS Message Reference 423 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 510
, SLOT cp-slot-number | CHASSIS, CRITICAL, , Password database conversion failed. Probable Cause Indicates that the password database conversion has failed. Recommended No action is required. Action Severity CRITICAL 424 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 511
. Probable Cause Indicates that the software watchdog detected termination of a restartable daemon and need to restart or failover the switch. Recommended Manually initiate a restart or failover the system. Action Severity CRITICAL Fabric OS Message Reference 425 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 512
46 HAM-1014 426 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 513
then execute the supportSave command and contact your switch service provider. Severity CRITICAL HAMK-1002 Message < result of a user-initiated action such as firmware download, the standby CP blade being reset or removed, or an error in the standby OS Message Reference 427 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 514
standby CP has been restarted. Note that in certain circumstances a CP may experience a double reset and restart twice in a row. A CP can recover automatically even if it has restarted twice. Recommended No action is required. Action Severity INFO 428 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 515
switch (for nonbladed switches power supply status. Try to reseat the faulty fan field-replaceable units (FRUs) and power supply FRU to verify that they are seated properly. If the problem persists, replace the fan FRU or the power supply FRU as necessary. Severity ERROR Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 516
(FRUs). For the Brocade 3900, replace the motherboard FRU. For the Brocade 4100, 4900, 7500, and AP7600, if the 12 volt level is faulty, replace one or both power supplies; if any other voltage is faulty, replace the entire switch. Severity ERROR 430 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 517
and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Run the fanShow command to monitor the speed of the fan generating this error. Fabric OS Message Reference 431 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 518
. Make sure that the area is well-ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Run the fanShow command to monitor the speed of the fan generating this error. If the - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 519
problem can quickly cause the switch to overheat. This message is specific to nonbladed switches and is not applicable to the Brocade 24000 or 48000. Recommended For the Brocade operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 520
removed. This message is often preceded by a low speed error message. This problem can cause the switch to overheat. Recommended Replace the affected fan FRU immediately. Action Severity WARNING HIL- is often preceded by a low fan speed message. 434 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 521
units (FRUs) have failed. This message is often preceded by a low fan speed message. Recommended Replace the faulty fan FRUs immediately. Action Severity ERROR Fabric OS Message Reference 435 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 522
message. Recommended Since the fans are not field replaceable, replace the switch if the temperature is high. Action Severity WARNING HIL-1311 Message - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 523
generate this message, it indicates oscillation between faulty and non-faulty behavior. Replace the switch because the fan is not field-replaceable. Severity INFO HIL-1401 Message , fan field-replaceable units (FRUs) have been removed. Fabric OS Message Reference 437 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 524
and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. If the message persists, replace to verify all the fans are working properly. Action 438 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 525
. Refer to the hardware reference manual for your switch for the operational temperature range. If the message persists, replace the faulty blade. Severity CRITICAL HIL-1504 Message , [HIL-1504], ,, INFO, , System within normal temperature specifications - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 526
. To help prevent future problems, make sure that all the fans are working properly. Make sure that the area is well-ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 527
Action To help prevent future problems, make sure that all the fans are working properly. Make sure that the area is well-ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 528
unit is faulty. Applicable only to Brocade 5100 and Brocade 6510. Recommended Ensure that the power cord is connected to the unit with a valid power source and then switch on Action the unit. If the problem persists, try reseating the unit. If the problem still persists replace the FRU. Severity - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 529
FAN Air Flows are in reverse direction. System will be shut down. Applicable only to Brocade 6510. Recommended Ensure fan units have same direction. Action Severity CRITICAL HIL-1613 Message < both WWN cards are inserted. Action Severity ERROR Fabric OS Message Reference 443 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 530
48 HIL-1650 444 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 531
from port , correct value . Probable Cause Indicates that the HLO message was incompatible with the value specified in the FSPF protocol. The Brocade switch will not accept FSPF frames from the remote switch. In the Fabric OS, the HLO dead timeout value is not configurable, so - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 532
an invalid HLO because either the domain or port number in the HLO message has an invalid value. This error can only occur when the Brocade switch is connected to a switch from another manufacturer. Recommended The HLO message of the remote switch must be compatible with the value specified in - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 533
the firmwareDownload command to reinstall the firmware to your switch. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL Fabric OS Message Reference 447 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 534
50 HMON-1001 448 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 535
Indicates an SFP is inserted. Recommended No action is required. Action Severity INFO HSL-1003 Message Probable Cause , [HSL-1003], ,, INFO, , SFP for interface is removed. Indicates an SFP is removed. Fabric OS Message Reference 449 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 536
Install more memory on board. Action Severity CRITICAL HSL-1007 Message Probable Cause , [HSL-1007], ,, ERROR, , Failed to read SFP for interface . Indicates a failure to read an SFP. 450 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 537
Recommended No action is required. Action Severity ERROR HSL-1007 51 Fabric OS Message Reference 451 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 538
51 HSL-1007 452 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 539
INFO, , Switch PIDformat has changed to . Probable Cause Recommended Action Indicates that the PID format was changed by the administrator. No action is required. For more information on PID format, refer to the Fabric OS Administrator's Guide. Severity INFO HTTP - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 540
52 HTTP-1003 454 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 541
failed. Disabling port. Probable Cause Indicates that the specified port has crashed unexpectedly and restarting attempts have failed. Recommended Power off and power on the blade using the slotPowerOff and slotPowerOn commands. Action Severity ERROR Fabric OS Message Reference 455 53-1002448 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 542
53 IBD-1000 456 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 543
>, iSCSI login sessions exceed the maximum limit at slot port ge Probable Cause Indicates that the iSCSI login sessions exceed the supported limit per port. Recommended Use another port to log in. Action Severity WARNING Fabric OS Message Reference 457 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 544
54 IBPD-1003 458 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 545
a new firmware version using the firmwareDownload command. Refer to the Fabric OS Command Reference for more information on this command. Severity ERROR ICPD-1003 Message , [ICPD-1003], ,, INFO, , iSCSI configuration has been committed by switch ( - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 546
Client service on a single switch in the fabric using the fosConfig command. Refer Action to the Fabric OS Command Reference for more information on this command. Severity WARNING ICPD-1005 Message , [ICPD-1005], ,, WARNING, , iSCSI configuration between - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 547
Recommended No action is required. Action Severity INFO ICPD-1008 55 Fabric OS Message Reference 461 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 548
55 ICPD-1008 462 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 549
is manual, this means that the address change was initiated by a user. If the source of the address change is the Dynamic Host Configuration Protocol >, Switch name has been successfully changed to . Indicates that the switch name has been changed. Fabric OS Message Reference 463 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 550
removed successfully. Probable Cause Indicates that the Domain Name System (DNS) parameters are removed successfully. Recommended No action is required. Action Severity INFO 464 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 551
Action Indicates that an initialization of a module within the IPS daemon failed. Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Command Reference Manual for more information on this command. Severity ERROR IPS-1003 Message , [IPS-1003 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 552
>, [IPS-1007], ,, WARNING, , FX8-24 blade () is not GA2 revision. Unable to use IPSec on FCIP Tunnel () Indicates that the tunnel configuration failed because the FX8-24 blade is not a GA2 compatible revision. 466 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 553
IPS-1007 57 Recommended Change the tunnel configuration to remove IPSec configurations or insert a GA2 revised FX8-24 Action blade. Severity WARNING Fabric OS Message Reference 467 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 554
57 IPS-1007 468 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 555
Configuration peering with external iSNS server slot/port /ge (current /ge - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 556
system-name>, Peering with external iSNS server not started because configuration unchanged. Indicates that peering with the external internet storage name service (iSNS) server was already started with the same configuration. 470 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 557
is required. You may change the configuration and retry the peering with the port. Refer to the appropriate hardware reference manual for valid slot and Action port ranges. Severity WARNING ISNS-1011 Message , [ISNS-1011], ,, INFO, , iSNS Client Service - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 558
server on management port. Probable Cause Indicates that peering has started with the specified external internet storage name service (iSNS) on the management port. Recommended No action is required. Action Severity INFO 472 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 559
operation to the primary or backup key vault. Recommended Determine whether the configured key value is operational, and if it is not, change the switch key Action vault settings or resolve the operational problem at the vault. Severity ERROR KAC-1006 Message , [KAC-1006], - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 560
the configured key value is operational, and if it is not, change the switch key Action vault settings or resolve the operational problem at the contents of the primary and secondary using instructions provided by the provider. Action Severity ERROR KAC OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 561
IP Address> failed. Actual Key: . Error code=, string=. Indicates that getting the Actual DEK failed from keyvault. Fabric OS Message Reference 475 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 562
communicate with the primary or backup key vault. Recommended Change the switch key vault settings and/or ensure that the configured key vault is operational. Action Severity ERROR KAC-1016 Message < No action is required. Action Severity ERROR 476 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 563
>:. Probable Cause Indicates a process on the switch has ended unexpectedly. Recommended Copy the warning message along with any core file information, and contact your switch service Action provider. Severity WARNING Fabric OS Message Reference 477 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 564
60 KSWD-1002 478 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 565
>, [KTRC-1004], ,, ERROR, , Cannot write to ATA dump device Indicates the write boundary in the ATA dump device has exceeded. Fabric OS Message Reference 479 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 566
. . . Probable Cause Indicates that a trace was unable to initialize. Recommended No action is required. Action Severity ERROR 480 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 567
-number>,, ERROR, , Message Queue Error: Message queue create failed. Probable Cause Indicates that the l2sys encountered System Service Manager (SSM) message queue errors. Recommended Restart the l2sys daemon. Action Severity ERROR Fabric OS Message Reference 481 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 568
the specified chip is less than 90 percent (%) full. Recommended No action is required. The l2sys starts learning the entries. Action Severity INFO 482 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 569
>, Hardware gid limit reached on chip , gid limit at . Probable Cause Indicates that all the dynamic Group IDs (GIDs) are allocated. Recommended Clear some of the ACL entries using the clear counters access-list mac command. Action Severity INFO Fabric OS Message Reference 483 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 570
62 L2SS-1008 484 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 571
Indicates an error in the hardware or the driver of the Layer 3 subsystem (L3SS). The L3SS may have passed invalid parameters or the hardware content-addressable memory (CAM) may be full. Recommended Retry or clear the CAM. Action Severity ERROR Fabric OS Message Reference 485 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 572
63 L3SS-1004 486 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 573
Link Aggregation Control Protocol (LACP) daemon has failed. Recommended Download a new firmware using the firmwareDownload command. Action Severity ERROR LACP-1002 Message , [LACP . Recommended No action is required. Action Severity ERROR Fabric OS Message Reference 487 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 574
64 LACP-1002 488 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 575
failed. Disabling port. Probable Cause Indicates that the specified port has crashed unexpectedly and restarting attempts have failed. Recommended Power off and power on the blade using the slotPowerOff and slotPowerOn commands. Action Severity ERROR Fabric OS Message Reference 489 53-1002448 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 576
65 LANCE-1000 490 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 577
Cause Indicates that the Logical Fabric Manager configuration is set to default. This will remove all prior Logical Fabric Manager configurations. This operation is not supported, currently. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 491 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 578
validation of firmware compatibility for XISL use on the specified switch has failed. Recommended Check release notes to verify if this firmware is compatible with XISL use. If it is not switch should Action be removed from the fabric. Severity WARNING 492 Fabric OS Message Reference 53-1002448 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 579
command for nonbladed switches or the haFailover command on bladed switches. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING Fabric OS Message Reference 493 53 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 580
needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity INFO LOG-1005 Message , [LOG-1005], ,, INFO, No action is required. Action Severity INFO 494 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 581
is from 1 through 239. The switch will discard the record because it is not supported. Recommended No action is required. switch generates its local link state record when first enabled. By disabling and enabling the switch, a new local link state record is generated. Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 582
. A new local link state record is generated Action during the switch enable. Severity CRITICAL LSDB-1004 Message Probable Cause , [LSDB required. The other switch will pass the LSD once the fabric is stable. Action Severity WARNING 496 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 583
. Action Severity ERROR MCAST_SS-1004 Message Probable Cause , [MCAST_SS-1004], ,, ERROR, , NSM error : () for vlan port . Indicates that mcast_ss encountered error while NSM event. Fabric OS Message Reference 497 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 584
, [MCAST_SS-1008], ,, ERROR, , HAL error : () - vlan mac/grp . Indicates that mcast_ss encountered HAL errors. 498 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 585
, IDB error: () port id not found. Probable Cause Indicates that the port ID passed is invalid. Recommended Try restarting the mcast_ssd reason>) Vlan vid not found. Indicates that the VID passed is invalid. Fabric OS Message Reference 499 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 586
], ,, ERROR, , Message error: () (). Indicates that length of the message recieved from the driver is invalid. 500 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 587
, , Learning error: () Invalid number for ifindex . Probable Cause Indicates that mcast_ss encountered an error macaddr> group . Indicates that mcast_ss encountered an error during List operation. Fabric OS Message Reference 501 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 588
69 MCAST_SS-1020 Recommended Try restarting the mcast_ssd daemon. Action Severity ERROR 502 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 589
limited to Fibre Connectivity (FICON) environments. Recommended No action is required if SB-3 link incident registration and reporting is not used by the host or if Action default values are desired for the switch node descriptor fields. Severity INFO Fabric OS Message Reference 503 53 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 590
required. IDID mode can be set using the configure command or by selecting the Advanced Web Tools Switch Admin > Configure Tab > Fabric Subtab > Insistent Domain ID Mode check box. The switch must be disabled to change the IDID mode. Severity WARNING 504 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 591
module has determined that there is no minimum cost path (MPath) available in the candidate list. Recommended No action is required. Action Severity WARNING Fabric OS Message Reference 505 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 592
71 MPTH-1003 506 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 593
: queue full (miss=) Probable Cause Indicates the corresponding message queue is full. Recommended No action is required. Action Severity WARNING Fabric OS Message Reference 507 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 594
size>) Probable Cause Indicates the incoming message size is larger than the message queue size. Recommended No action is required. Action Severity WARNING 508 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 595
Cause Indicates the management server (MS) has segmented from another switch domain at the specified port number because of errors or inconsistencies defined in the MS platform service. Recommended Restart or power cycle the switch. Action Severity WARNING MS-1002 Message , [MS-1002 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 596
firmwareDownload command to upgrade the firmware level on the switch to a level that supports RCS. RCS is supported in Fabric OS v2.6, v3.1 and then run the supportSave command and contact your switch service provider. Severity INFO MS-1004 Message - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 597
violates the Fibre Channel Generic Services (FS-GS) specification. Recommended Check the integrity of the FC switch at Service Queue. • MS is unable to add a timer to a resource. Recommended This message is often transitory. Action Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 598
number>,, ERROR, , RLIR event. Switch Port ID is (). Device Port Tag is . . Probable Cause Indicates result of SAN hardware problems such as bad cables or small form-factor pluggables (SFPs). It may be necessary to replace hardware if - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 599
the MS Platform Service was being enabled, a failover has occurred. This can leave the fabric in an inconsistent state. Recommended If there is an inconsistency in the Platform service within the fabric, enable the Platform service. Action Severity WARNING Fabric OS Message Reference 513 53 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 600
is blocked. Recommended Enable Platform service on the switch and renable the port to join the fabric. Action Severity WARNING MS-1027 Message , [MS-1027], ,, INFO, , Fabric Name configured. Probable Cause Indicates that the fabric name - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 601
initialize. Recommended Restart or power cycle the switch. Action Severity ERROR MSTP- switch, execute the haFailover command. If the problem persists or if this is a nonbladed switch, download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Command Reference Manual - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 602
, [MSTP-2005], ,, INFO, , Vlan is on MSTP instance . Indicates that the MSTP instance has modified. 516 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 603
is changed from to . Probable Cause Indicates that the MSTP instance priority has modified. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 517 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 604
74 MSTP-2006 518 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 605
). NBFSM states are as follows: • 0 - Down • 1 - Init • 2 - Database Exchange • 3 - Database Acknowledge Wait • 4 - Database Wait • 5 - Full If this error occurs repeatedly, then there is a problem in the protocol implementation between two switches. Fabric OS Message Reference 519 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 606
) states are as follows: • 0 - Down • 1 - Init • 2 - Database Exchange • 3 - Database Acknowledge Wait • 4 - Database Wait • 5 - Full Recommended No action is required. The Fabric OS automatically recovers from this problem. Action Severity WARNING 520 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 607
lower supported capability than the active CP because of different firmware versions running on the active and standby CPs. This means that the active and standby CPs are out of sync. Any execution of the haFailover or firmwareDownload commands will be disruptive. Fabric OS Message Reference 521 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 608
of the lowest version of firmware. Severity INFO NS-1005 Message , [NS-1005], ,, WARNING, , Zone size of has over the supporting limit of for the remote switch domain ID . Probable Cause - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 609
Open FR devices to a licensed switch. Action Severity WARNING NS-1009 Message port. Probable Cause Indicates the CSCTL mode enabled for a port with devices as members of a QoS zone. Recommended Remove CSCTL configured devices from QoS zone. Action Severity WARNING Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 610
Cause Indicates that a failover flag has disabled TI zone in a base switch fabric. Recommended Modify failover flag to enable or remove TI zone with PID>. Probable Cause Indicates that the devices with the same World Wide Port Name (WWPN) have been removed from the Name Server database. - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 611
down • DOT1x authenticating • Minumum member links not UP (applicable only for port-channel interfaces) • DOT1x authentication failed • BRCD remote link negotiation failed/LLDP disabled • LAG negotiating/failed • LAG admin state is down • UNKNOWN Severity INFO Fabric OS Message Reference 525 53 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 612
Fibre Channel over Ethernet (FCoE) VLAN is used in the FCoE daemon (fcoed) and therefore cannot be disabled. Recommended Disable FCoE VLAN by removing all the FCoE sessions from its member ports Recommended No action is required. Action Severity INFO 526 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 613
to for interface . Probable Cause Indicates that the interface mode has been changed. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 527 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 614
is created. Probable Cause Indicates that the specified VLAN classifier rule has been created. Recommended No action is required. Action Severity INFO 528 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 615
> will be allowed on interface . Probable Cause Indicates that the VLAN membership has been changed. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 529 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 616
. Probable Cause Indicates that the administrative status of the specified interface has changed to down. Recommended No action is required. Action Severity INFO 530 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 617
number>,, INFO, , LLDP global configuration is changed. Probable Cause Indicates that the LLDP global configuration has been changed. Recommended No action is . Indicates that LLDP is enabled on the specified interface. Fabric OS Message Reference 531 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 618
the Converged Enhanced Ethernet (CEE) version and the pre-CEE version depending on the neighbor. Recommended No action is required. Action Severity INFO 532 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 619
Run the firmwareDownload command to reinstall the firmware. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING Fabric OS Message Reference 533 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 620
configuration file sync.conf contains too many entries. Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 621
Run the firmwareDownload command to reinstall the firmware. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING Fabric OS Message Reference 535 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 622
the supportSave command and contact your switch service provider. Severity WARNING PDM-1014 Message Probable Cause , [PDM-1014], ,, WARNING, , Access sysmod failed. Indicates a system call to sysMod failed. 536 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 623
the firmware. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. for the files to be replicated. Action Severity WARNING Fabric OS Message Reference 537 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 624
sequence-number>,, WARNING, , DNS is configured for IPv6. Indicates that the parity data manager (PDM) cannot synchronize with its peer because the domain name service (DNS) is configured for IPv6. IPv6 is not supported by older firmware. 538 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 625
the parity data manager (PDM) cannot synchronize with its peer because the user defined roles are configured. User defined roles are not supported by older firmware. Recommended Remove the configured user defined roles. Action Severity WARNING Fabric OS Message Reference 539 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 626
79 PDM-1026 540 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 627
the watch dog timer (WDT) forced a core reset. • 0x20000000 bit set means that the WDT forced a chip reset. • All other code values are reserved. Recommended Run the pdShow command to view the panic dump and core dump files. Action Severity INFO Fabric OS Message Reference 541 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 628
80 PDTR-1002 542 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 629
and contact your switch service provider. Severity CRITICAL specific> CP Error . Indicates that the CP cannot access the I2C subsystem either because of an error condtion or being fenced or isolated from the I2C bus. Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 630
-number>, FFDC, CRITICAL, , Switch has older FPGA rev 0x via the fpga_update command. Probable Cause Indicates Fabric OS has a newer FPGA version. Recommended Upgrade FPGA to new version. Action Severity CRITICAL 544 Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 631
INFO PMGR-1004 Message Probable Cause , [PMGR-1004], , WARNING, , Attempt to delete switch failed. Error message: . Indicates that the switch with the specified FID was not deleted. Fabric OS Message Reference 545 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 632
PMGR-1008 Message Probable Cause , [PMGR-1008], , WARNING, ,Attempt to change switch to switch failed. Error message: . Indicates the failed attempt to change the switch FID. 546 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 633
[PMGR-1011], , INFO, , Attempt to move ports to switch succeeded. Probable Cause Indicates the successful attempt to move the ports to the specified switch. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 547 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 634
82 PMGR-1011 548 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 635
L_port, but the port does not support L_port. If an L_port is connected, then the port will be disabled because the port does not support L_port. If an E_port or F_port is connected, then the port will not come up since it is configured to be an L_port. Fabric OS Message Reference 549 53-1002448 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 636
Recommended Invoke the portCfgLport command to clear the L_port configuration. Action Severity WARNING PORT-1006 Message , [PORT-1006], ,, INFO, , Configuration changed for port (ID: ) in No_Module or No_Light state. Probable Cause Indicates - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 637
QOS is disabled. Probable Cause The Port QOS is disabled because the port currently has Best Effort Setting that requires QOS to be disabled on a 4G or 8G long distance platform. Recommended This is normal; no action required. Action Severity INFO Fabric OS Message Reference 551 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 638
83 PORT-1010 552 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 639
>, [PS-1001], ,, INFO, , Advanced Performance Monitoring configuration updated due to change in PID format Indicates the PID format was changed. No action is required. Refer to the Fabric OS Administrator's Guide for more information on the PID format. INFO PS-1002 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 640
end monitors are configured on the switch. Recommended Delete the end-to-end monitors on that switch and re-install the fabricmode TopTalker monitor. Action End-to-end monitors and fabricmode Top Talker monitors are mutually exclusive. Severity WARNING 554 Fabric OS Message Reference 53-1002448 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 641
. Top Talker cannot be installed on fabric with FC router or McData mode enabled. In case if the top talker has to be installed on fabric, FC router and McData mode has to be disabled. maximum limit as mentioned in documents. Action Severity WARNING Fabric OS Message Reference 555 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 642
84 PS-1009 556 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 643
, [PSWP-1003], ,, INFO, , Port Swap feature disabled. Probable Cause Indicates that the portSwap command feature has been disabled in the switch. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 557 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 644
.>in switch number . Probable Cause Indicates that the bladeSwap command has failed to access the switch context. Recommended Retry the command. If the failure persists, contact your support representative. Action Severity WARNING 558 Fabric OS Message Reference 53 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 645
automatic FTP transfers; then execute the Action supportSave command and contact your switch service provider. Severity INFO RAS-1002 Message , [RAS-1002], supportSave command and contact your switch service provider. Severity WARNING Fabric OS Message Reference 559 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 646
switch service provider. Severity WARNING RAS-1006 Message , [RAS-1006], , INFO, , Support Cause Indicates that the support data was automatically transferred from the switch to the configured remote server. Recommended OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 647
, Audit message class configuration has been changed to . Probable Cause Indicates that the audit event class configuration has been changed. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 561 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 648
>, USB storage device disabled. Probable Cause Indicates that the USB storage device has been disabled. Recommended No action is required. Action Severity INFO 562 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 649
supported in Fabric OS v2.6, v3.1 and later, and v4.1 and later. Run the firmwareDownload command to upgrade the firmware for any switches that do not support on the switch using the memShow command. Restart or power cycle the switch. Severity ERROR Fabric OS Message Reference 563 53-1002448 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 650
rcsInfoShow command to view RCS capability on the fabric. RCS is supported in Fabric OS v2.6, v3.1 and later, and v4.1 and later. Run the firmwareDownload command to upgrade the firmware for any switches that do not support RCS. Severity ERROR RCS-1005 Message , [RCS-1005], - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 651
RCS. Probable Cause Indicates a remote domain is requested to go offline, to take it out of the fabric, because it does not support RCS. Recommended Run the fabricShow command to verify that remote domain is out of the fabric. Action Severity INFO Fabric OS Message Reference 565 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 652
ports disabled> E-port(s) connected to this domain. Probable Cause Indicates the remote domain is non-RCS and necessary action need to be taken to join RCS fabric. Recommended Configure the remote domain as RCS capable switch Action Severity WARNING 566 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 653
String> SK/ASC: /. Indicates that a First time encryption/re-key/Write Metadata encountered a fatal SCSI error and was suspended. Fabric OS Message Reference 567 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 654
number>,, WARNING, , LUN with LSN: does no have metadata. Please make note of key ID that will be used for encryption/decryption of the LUN the container with -newLUN option. Action Severity WARNING 568 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 655
Action Check the traffic on the interface using the show interface command. Note that you can use the show interface command to check the traffic on Action Check the traffic on the interface using the show interface command. Note that you can use the show interface command to check the traffic on - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 656
89 RMON-1002 570 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 657
Indicates the SSL certificate file configured on the switch could not be accessed because the root did not have read-level access. Recommended Change the file system access level for the certificate to root read-level access. Action Severity WARNING Fabric OS Message Reference 571 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 658
private key file. Secure RPCd is disabled. Probable Cause Indicates the private key file configured on the switch could not be accessed because the root did not have read-level access. Recommended a valid private key file. Action Severity WARNING 572 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 659
) are not synchronized from active control processor (CP) to standby CP during the failover. This event causes route inconsistencies. Recommended Reset all E_ports on the chassis using the portDisable and portEnable commands. Action Severity ERROR Fabric OS Message Reference 573 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 660
91 RTE-1001 574 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 661
error, and more specific error information. switch with the specified domain ID. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers and run the supportSave command then contact your switch service provider. Severity WARNING Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 662
ID is reachable. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers and run the supportSave command then contact your switch service provider. Severity INFO 576 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 663
state change notification (SCN) message to a specific queue has failed because the SCN queue listed below. For a complete listing, see the Introduction to this manual. • fabricd • asd • evmd • fcpd • webd • switch service provider. Severity CRITICAL Fabric OS Message Reference 577 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 664
a secure server location. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR 578 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 665
configuration server (FCS) switch. This might be caused by several factors: the data package may be corrupted, the time stamp on the package may be out of range as a result of replay attack or out-of-sync time service security policy. Severity ERROR Fabric OS Message Reference 579 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 666
and contact your switch service provider. Severity WARNING SEC-1005 Message , [SEC-1005], ,, INFO, , Primary FCS receives data request from domain . Probable Cause Indicates the primary fabric configuration server (FCS) received a data - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 667
displayed in the message. Recommended Check for unauthorized access to the switch through the Telnet connection. Action Severity INFO SEC-1010 Message Probable distribute the database from a non primary switch. Resolved the above specified error. Fabric OS Message Reference 581 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 668
Recommended Resolve the above specifed error by executing the command only from Primary FCS. Action Severity ERROR SEC switch. If the private key does not exist, follow the steps for recreating PKI objects, outlined in the Secure Fabric OS Administrator's Guide OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 669
primary fabric configuration server (FCS) distributes the security database to the other switches in the fabric switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific switch. Severity ERROR Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 670
only when the primary fabric configuration server (FCS) distributes the security database to the other switches in the fabric, then specific switch. Severity ERROR SEC-1031 Message , [SEC-1031], ,, WARNING, , Current security policy DB cannot be supported - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 671
command supports use of the asterisk for adding switches to policies. Recommended Action Run the secPolicyAdd command using a valid switch identifier (WWN, domain ID, or switch name) to add specific switches to the switch connection control (SCC) policy. Refer to the Fabric OS Command Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 672
Verify that the domain ID is correct. If it is not, then rerun the command using the correct domain Action ID. Severity ERROR 586 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 673
numbers. Action Severity ERROR SEC-1043 Message Probable Cause , [SEC-1043], ,, ERROR, , Invalid port range - . Indicates the specified port is not within the minimum and maximum range. Fabric OS Message Reference 587 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 674
fabric configuration server (FCS) is distributing the security database to the other switches in the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific switch. Severity ERROR 588 Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 675
primary fabric configuration server (FCS) is distributing the security database to the other switches in the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific switch. Severity ERROR Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 676
fabric configuration server (FCS) is distributing the security database to the other switches in the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific switch. Severity ERROR 590 Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 677
primary fabric configuration server (FCS) is distributing the security database to the other switches in the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific switch. Severity ERROR Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 678
no domains or domains more than the maximum number supported are specified. Recommended Enter the correct number of domains Cause Indicates the public key infrastructure (PKI) objects on the switch are not in a valid state and the signature operation failed. OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 679
the specific policy type is empty. The security database is corrupted for unknown reasons. Recommended Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command Action and contact your switch service provider. Severity ERROR Fabric OS Message Reference 593 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 680
fabric configuration server (FCS) is distributing the security database to the other switches in the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific switch. Severity ERROR 594 Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 681
others nodes in the zone. Recommended Re-enable the current zone configuration for the change to take effect. Action Severity ERROR SEC- -name>, Failed to activate new policy set on all switches. Probable Cause Indicates the policy could not be activated. OS Message Reference 595 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 682
the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific switch OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 683
primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific switch OS Message Reference 597 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 684
the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific switch OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 685
primary fabric configuration server (FCS) is distributing the security database to the other switches in the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific switch. Severity ERROR Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 686
fabric configuration server (FCS) is distributing the security database to the other switches in the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific switch. Severity ERROR 600 Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 687
command and contact your switch service provider. Severity ERROR configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 688
specific switch. Severity ERROR SEC-1100 Message , [SEC-1100], ,, ERROR, , FCS switch when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 689
. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Fabric OS Message Reference 603 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 690
the defined and active fabric configuration server (FCS) policy list failed to have at least one member in common. Recommended A new FCS policy list must have at least one member in common with the previous FCS policy. Action Severity ERROR 604 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 691
SEC-1115 Message Probable Cause , [SEC-1115], ,, ERROR, , No primary FCS to failover. Indicates that during an attempted secFcsFailover, no primary fabric configurations server (FCS) is present in the fabric. Fabric OS Message Reference 605 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 692
failed to save the data received by the primary fabric configuration server (FCS) switch. This data can be an FCS password, a non-FCS password, SNMP data, or multiple user authentication data. Recommended Run the secFabricShow command to verify that all switches in the fabric are in the ready state - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 693
event was planned, verify that all switches in the fabric are in time synchronization with the primary FCS and that no external entity is trying FCS. Indicates the security database was successfully downloaded from the primary fabric configuration server (FCS). Fabric OS Message Reference 607 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 694
-name>, The Primary FCS has failed over to a new switch. Probable Cause Indicates an fabric configuration server (FCS) failover operation was >, Secure fabric version stamp has been reset. Indicates the version stamp of the secure fabric is reset. 608 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 695
Probable Cause , [SEC-1138], ,, INFO, , Security database download received from Primary FCS. Indicates that a non-primary fabric configuration server (FCS) switch received a security database download. Fabric OS Message Reference 609 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 696
for individual event is: . Indicates one of the following has occurred: • The names for the specified policies have changed. • The passwords have changed for the specified accounts. • The SNMP community strings have been changed. 610 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 697
switch support RCS, obtain the latest firmware version from your switch supplier, and run the firmwareDownload command to upgrade the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service switch - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 698
the failed command. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity INFO 612 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 699
updated for that specific switch. Severity INFO SEC-1160 Message , [SEC-1160], ,, INFO, , Duplicate port in port list (). Probable Cause Indicates a duplicate port member exists in the specified port list. Recommended Verify - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 700
fabric configuration server (FCS) is distributing the security database to the other switches in the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific switch. Severity ERROR 614 Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 701
primary fabric configuration server (FCS) is distributing the security database to the other switches in the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific switch. Severity INFO Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 702
command to create them for the switch. Run the licenseAdd command to install the required license key. Refer to your switch supplier to obtain a license if FCS or non-FCS> password. Indicates the fabric configuration server (FCS) or non-FCS password could not be set. 616 Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 703
Indicates the primary fabric configuration server (FCS) failed to generate a new version stamp due to the fabric not being stable. Recommended Verify all switches in the fabric are . Indicates the specified account has been deleted. Fabric OS Message Reference 617 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 704
to the specified Remote Authentication Dial-in User Service (RADIUS) / Lightweight Directory Access Protocol (LDAP) server configuration. The possible actions are ADD, REMOVE, CHANGE, and MOVE Recommended No action is required. Action Severity INFO 618 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 705
, , Configuration. Probable Cause Indicates the remote authentication dial-in user service (RADIUS/LDAP) configuration was enabled or disabled as the primary authentication, accounting, and authorization (AAA) mechanism. Recommended No action - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 706
/area of switch . Probable Cause Indicates a device connection control (DCC) security violation was reported. The specified device attempted to login using fabric login (FLOGI) to an unauthorized port. The DCC policy correlates specific devices to specific port locations - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 707
connection method; the login failed. Recommended The error message lists the violating IP address. Verify that this IP address is being used by a valid Action switch admin. Use the correct password. Severity INFO Fabric OS Message Reference 621 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 708
Indicates the default switch accounts admin and user do not exist on the switch when enabling security. Recommended Reset the default admin and user account names on the switch that reported the warning and retry Action enabling security. Severity WARNING 622 Fabric OS Message Reference 53 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 709
Security violation: MS command is forwarded from non-primary FCS switch. Indicates a management server (MS) forward security violation was reported. A management server command was forwarded from a non-primary fabric configuration server (FCS) switch. Fabric OS Message Reference 623 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 710
was reported. An MS device operation occurred on a non-primary fabric configuration server (FCS) switch. Recommended Action Check the management server policy and verify the connection is Recommended No action is required. Action Severity INFO 624 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 711
your switch service provider. Severity ERROR SEC-1300 Message Probable Cause , [SEC-1300], ,, INFO, , This switch is in VcEncode mode. Security is not supported. Indicates the switch is set up with VC-encoded mode. Fabric OS Message Reference 625 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 712
the Brocade Secure Fabric OS feature. Recommended Run the firmwareDownload command to update the firmware to the latest version for your specific Action switch. Verify the firmware you are installing supports the Brocade Secure Fabric OS feature. Severity INFO 626 Fabric OS Message Reference 53 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 713
when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and OS Administrator's Guide. If PKI objects are valid, verify that an unauthorized switch is not trying to access the fabric. Severity INFO Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 714
have failed to respond. Probable Cause Indicates that all servers in the remote authentication dial-in user service (RADIUS) configuration have failed to respond to a switch request within the specified time-out. Recommended Verify the switch has proper network connectivity to the specified remote - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 715
was planned, run the passwdCfg --setDefault command on each switch in the fabric to set the password policies to the default value. Then verify with passwdCfg --show that password policies are set to the default values on all switches and retry the secModeEnable command. Severity ERROR SEC-1312 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 716
problem persists contact your switch service provider. Action Severity ERROR SEC-1315 Message , [SEC-1315], ,, ERROR, , command failed - db(s) configured OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 717
fabric with strict fabric wide policy Probable Cause Indicates that a domain not supporting an access control list (ACL) policy tried to join a fabric with the switch has a conflicting configuration such as fabric wide consistency configuration or AD configuration. Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 718
support a device connection control (DCC) policy with more than 256 ports. Recommended Reconfigure any policy that includes more than 256 ports in its member list, then save the policy Action configuration the reliable commit service (RCS) transaction failed OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 719
, [SEC-1328], ,, ERROR, , Attempt to enable secure mode failed. Reason: . Indicates the secModeEnable command failed on the fabric because Authentication Policy is enabled on the switch. Fabric OS Message Reference 633 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 720
. Probable Cause Indicates an attempt was made to distribute databases either from a backup fabric configuration server (FCS) switch or from a non-FCS switch. Recommended Verify the distribution is initiated by the primary FCS switch. Use the secPolicyShow command to Action verify and correct the - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 721
Recommended Remove either the FCS from the fabric-wide policy, or remove 5.3 and 5.2 switches from the fabric, Action or set the fabric-wide mode for FCS as Strict. Severity ERROR Domain Number>. Indicates the policy is conflicting with the domain. Fabric OS Message Reference 635 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 722
Number, have a conflicting policy with the local switch. Recommended Check the conflicting policy and make the new switches and the local switch policies the same. Action Severity WARNING SEC-3005 by your enterprise security policy. Severity INFO 636 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 723
establish connection using . Indicates that a security violation was reported. The IP address of the unauthorized host is displayed in the message. Fabric OS Message Reference 637 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 724
switch through the specified protocol connection. Action Severity INFO SEC-3050 Message , [SEC-3050], , INFO, , Event: , Status: success, Info: - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 725
, INFO, , Permission to the RBAC class(es) is changed for the role . Probable Cause Configuration of user-defined roles is downloaded. Indicates the configuration of user-defined roles have been downloaded. Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 726
logged in . Probable Cause Indicates the client has logged in. Recommended No action is required. Action Severity INFO 640 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 727
, , Global sFlow polling interval is changed to . Indicates that the global counter sampling interval has been changed to the specified value. Fabric OS Message Reference 641 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 728
Message Probable Cause , [SFLO-1008], ,, INFO, , All the sFlow collectors are unconfigured. Indicates that none of the sFlow collectors are configured. 642 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 729
Recommended No action is required. Action Severity INFO SFLO-1008 95 Fabric OS Message Reference 643 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 730
95 SFLO-1008 644 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 731
that the Simple Network Management Protocol (SNMP) service could not be started because of the specified reason. Therefore, you will not be able to query the switch through SNMP. Recommended Verify that the IP address for the Ethernet and Fibre Channel interface is set correctly. If the Action - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 732
-name>, configuration was reset to default. Probable Cause Indicates that the specified SNMP configuration group was reset to the factory default. Recommended Execute the the current fabric status. Action Severity INFO 646 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 733
-name>, Port traps are on port . Probable Cause Indicates the blocked or unblocked status of the port traps on the specified port. Recommended Execute the snmpTraps command to view the current status of the port. Action Severity INFO Fabric OS Message Reference 647 53 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 734
96 SNMP-1009 648 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 735
To recover a bladed system, execute the slotPowerOff and slotPowerOn commands on the blade. To Action recover a non-bladed system, execute the fastboot command on the switch. Severity ERROR Fabric OS Message Reference 649 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 736
INFO SPC-2004 Message Probable Cause , [SPC-2004], ,, ERROR, , S, : FPGA firmware download failed: 0x. Indicates the FPGA download has failed. 650 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 737
number containing Encryption Engine>, : FPGA firmware download success: 0x. Probable Cause Indicates the tests failed: 0x. Probable Cause Indicates the Crypto Power-On Self-Test (POST) tests have failed. Recommended No . Fabric OS Message Reference 651 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 738
crypto BIST success. Probable Cause Indicates the FPGA built-in self test (BIST) was successful. Recommended No action is required. Action Severity INFO 652 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 739
hardware failure. Recommended Shelf life of the system may be reduced. Contact the vendor for further instructions Recommended System operation will be unaffected while facility power is present. Schedule replacement with the Action vendor. keyappd. Fabric OS Message Reference 653 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 740
Probable Cause Indicates an allocation failure for pool for switch board (SB) message. Recommended No action is required. - no free sbmsgs. Probable Cause Indicates no free message buffer in free pool. Recommended No action is required. Action . 654 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 741
be rewrapped does not exist within the EE Crypto Module. Recommended No action is required. The KEK will be recovered automatically. Action Severity ERROR Fabric OS Message Reference 655 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 742
33 - FGPA error upon inject • 73 - Invalid KEK format Recommended Contact your switch service provider for assistance. Action Severity ERROR SPC-3006 Message Probable Cause , [SPC-3006 - FGPA error upon inject • 73 - Invalid KEK format 656 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 743
cause depends on the SP status code: • 2 - Invalid input DEK specification • 21 - No primary KEK exists with which to wrap the DEK • complete primary KEK generation; otherwise, contact your switch service Action provider. Severity ERROR SPC-3008 Message < OS Message Reference 657 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 744
containing Encryption Engine>, : SEK generation failure: . Indicates the Crypto Module internal Secret Encryption Key could not be generated. 658 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 745
Engine>, : RSA pairwise key generation test failure. Probable Cause Indicates the Crypto Module could not generate its internal key pair. Recommended Contact your switch service provider for assistance. Action Severity ERROR Fabric OS Message Reference 659 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 746
97 SPC-3015 660 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 747
and restart the switch. Action Severity ERROR configured. Recommended No action is required. Action Severity INFO SPM-1004 Message Probable Cause , [SPM-1004], ,, INFO, , Initialize Node. Indicates a node initialization. Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 748
action . Probable Cause Indicates encryption engine (EE) control slot configuration. Recommended No action is required. Action Severity INFO SPM-1006 Message , slot . Indicates an SP certificate de-registration. 662 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 749
the quorum size. Recommended No action is required. Action Severity INFO SPM-1012 Message Probable Cause , [SPM-1012], ,, INFO, , Authentication Context:. Indicates an authentication context. Fabric OS Message Reference 663 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 750
effective unless imported as the EE may have different MK configured. Recommended Import required MK(s) using cryptocfg --recovermastekey command to Recommended Use cryptocfg --sync -securitydb to manually sync security db. Action Severity WARNING 664 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 751
to distribute security database. Recommended Use the cryptocfg --sync -securitydb command to manually sync security db. Action Severity WARNING SPM-3001 Message , [SPM- . Recommended No action is required. Action Severity INFO Fabric OS Message Reference 665 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 752
imported via scp: []:. Probable Cause Indicates a file was imported using SCP protocol. Recommended No action is required. Action Severity INFO 666 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 753
: cryptocfg Status: success, Info: Local file \"\" deleted. Probable Cause Indicates a locally stored file was deleted. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 667 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 754
], ,, INFO, ,Event: cryptocfg Status: success, Info: Key vault type set to . Indicates the key vault type was set. 668 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 755
], ,, INFO, ,Event: cryptocfg Status: success, Info: System card registered. Certificate label: \"\" Certificate file: \"\". Indicates a system card was registered. Fabric OS Message Reference 669 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 756
: cryptocfg Status: success, Info: Authentication card with certificate label \"\" deregistered. Probable Cause Indicates an authentication card was de-registered. Recommended No >. Indicates use of the system card was enabled or disabled. 670 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 757
], ,, INFO, ,Event: cryptocfg Status: success, Info: Recovery card registered. Certificate label: \"\" Certificate file: \"\". Indicates a recovery card was registered. Fabric OS Message Reference 671 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 758
Connection Status: , Info:KAC_Connect: . Probable Cause Indicates the status of key vault. Recommended No action is required. Action Severity INFO 672 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 759
. After the problem is corrected, support information to the USB storage device. Probable Cause Indicates that the supportSave command was used to transfer support information to an attached USB storage device. Recommended No action is required. Action Severity INFO Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 760
Execute the usbstorage command to check the USB storage device settings. After the USB problem Action is corrected, execute the supportSave command again. Severity WARNING SS-1004 Message < was not sent to the blade in the specified slot. 674 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 761
BP/DP)>. Probable Cause Indicates that there is no Inter-Subsystem Communication (ISC) connection for the specified node slot. Recommended Restart the switch using the reboot command and then execute the supportSave command. Action Severity WARNING Fabric OS Message Reference 675 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 762
99 SS-1009 676 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 763
initialization of a module within System Services Manager (SSM) has failed. Recommended Download a new firmware version using the firmwareDownload command. Action (semaphore). Recommended Restart or power cycle the switch. Action Severity ERROR Fabric OS Message Reference 677 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 764
power cycle the switch. If the probelm persists, download a new firmware using the Action firmwareDownload command. Severity ERROR SSMD-1006 Message , [SSMD-1006], ,, ERROR, , Error while configuring . 678 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 765
application-specific integrated circuit (ASIC) for the enforcing Multicast Rate Limit feature. Recommended Action Delete and reapply Quality of Service (QoS) Multicast Rate Limit policy using the qos rcv-queue multicast rate-limit command. If the problem persists, restart or power cycle the switch - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 766
Delete and reapply the QoS 802.3x Pause flow control policy using the qos flowcontrol command. If the problem persists, restart or power cycle the switch. Severity WARNING SSMD-1203 Message (CEE) Map Enhanced Transmission Selection (ETS) feature. 680 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 767
for enforcing the CEE Map Class of Service (CoS) to Priority Group ID (PGID) mapping feature. Recommended Action Delete and reapply the CEE Map CoS to PGID policy using the cee-map default command. If the problem persists, restart or power cycle the switch. Severity WARNING SSMD-1207 Message - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 768
interface CoS to Traffic Class policy using the qos cos-traffic-class command. If the problem persists, restart or power cycle the switch. Severity WARNING SSMD command. If the problem persists, restart or power cycle the switch. Severity WARNING 682 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 769
Tail Drop Threshold policy using the qos rcv-queue command. If the problem persists, restart or power cycle the switch. Severity WARNING SSMD-1215 Message Probable Cause , [SSMD-1215], the interface CoS Tail Drop Threshold feature. Fabric OS Message Reference 683 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 770
Map and Fibre Channel over Ethernet (FCoE) configuration into an ETS scheduler policy implementable by the dataplane ASIC. Recommended Redefine CEE map and FCoE into a configuration that translates into into an ETS scheduler policy Action requiring eight or fewer traffic classes. Severity WARNING - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 771
, , CEE Map priority group weight is changed from to . Indicates that the specified PG weight has been changed. Fabric OS Message Reference 685 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 772
rule sequence number is . Indicates that the specified access list rules were added to or removed from an existing policy. 686 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 773
, ACL configured on interface . Probable Cause Indicates that the specified access list has been configured on the interface. Recommended No that the specified user profile map has removed from the interface. Fabric OS Message Reference 687 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 774
with the current firmware and therefore it is reset to default. Recommended No action is required. Action Severity INFO SSMD-1316 Message Probable Cause , [SSMD-1316], ,, INFO, , CEE Map is reset to default configuration. Indicates that the - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 775
a long time. Probable Cause Indicates that the specified access list is being removed from the interface. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 689 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 776
100 SSMD-1318 690 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 777
Recommended Action Do not fail over or power down the system during firmware upgrade. Allow the firmwareDownload command to continue firmwareDownload command has completed successfully and switch firmware has been updated. Recommended Action No Fabric OS Message Reference 691 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 778
. Probable Cause Indicates the standby CP is rebooting with new firmware. Recommended Action No action is required. The firmwareDownload command is progressing as expected. Run the firmwareDownloadStatus command for more information. Severity INFO 692 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 779
CP." "firmwareDownload failed." "firmwareDownload failed due to IPC error." "Unable to check the firmware version on Standby CP due to IPC error." "firmwareDownload failed due to IPC error." " 0x42 0x43 0x44 0x50 0x51 0x52 0x53 0x54 0x55 Fabric OS Message Reference 693 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 780
firmware version on Standby CP due to IPC error." "Unable to restore the original firmware check the firmware version on see firmware firmware." "Standby CP failed to boot up with new firmware firmware." "Standby CP failed to boot up with new firmware ." "The original firmware has been restored - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 781
"New firmware failed to boot up. Please retry firmwareDownload." 0xa6 "firmwareCommit has started on the blade. This may take up to 10 minutes." 0xa7 "firmwareRestore is entered. System will reboot and a firmwareCommit operation will start 0xa8 upon boot up." Fabric OS Message Reference 695 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 782
list file. Check whether the switch is supported by the requested firmware. Also check firmwareDownload help page for service provider for recovery." 0x13 "Out of memory." 0x14 "Failed to download RPM package." 0x15 "Unable to create firmware 696 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 783
firmware on the switch may be two releases older than the requested firmware. firmwareDownload supports firmware upgrades within two feature releases (a feature release is indicated by a major number and a minor number, for example, X.Y). The following are major upgrade versions for the Fabric OS - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 784
director-class switch, when firmwareDownload fails, the command will synchronize the firmware on the two partitions of each CP by starting a firmware commit operation. Wait until this operation completes (about 10 minutes) before attempting another firmwareDownload. 698 Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 785
firmware onto the CPs. Refer to the Fabric OS Administrator's Guide for troubleshooting , contact your switch service provider. Action firmware stored on the active CP. It may also be caused by an internal Ethernet issue or by a persistent storage hardware failure. Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 786
remove and re-insert the blade to trigger another firmwareDownload. If the problem persists, contact your switch service provider. Severity ERROR SULB-1020 Message , [SULB-1020], ERROR, , New firmware failed to boot in slot . Probable Cause Indicates the BP - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 787
command, for example, by powering off and on of the indicated also be caused by persistent storage hardware failure or by a software error problem persists, contact your switch service provider. Severity WARNING SULB-1024 Message , [SULB-1024], WARNING, , Firmware - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 788
SULB-1031 Message Probable Cause , [SULB-1031], , WARNING, , The switch is relocating an internal firmware image. Indicates the switch has rebooted with the new firmware and is relocating the AP firmware. 702 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 789
firmware image on the CP. Probable Cause Indicates the switch has started a firmware switch. Recommended Run the firmwareShow command to verify the firmware versions. Run the switchShow command to Action make sure the switch by the switch initialization problem persists, contact your switch service - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 790
by inconsistent internal firmware image. It may also be caused by the internal Ethernet or persistent storage hardware failure. Recommended Reset the switch. This will cause the internal image to be relocated again. If the problem persists, Action contact your switch service provider. Severity - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 791
problem persists, contact your switch service provider. Severity WARNING SULB-1041 Message , [SULB-1041], , INFO, , Firmware command has completed successfully and switch firmware has been updated. Fabric OS Message Reference 705 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 792
Cause Indicates the firmwareDownload to secondary partition has completed successfully and switch will come up with updated firmware on reboot. Recommended No action is required. Switch will auto reboot with downloaded firmware. Action Severity INFO 706 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 793
the supportSave command and contact your switch service provider. Severity ERROR SWCH-1002 Brocade 24000 or 48000 switch, run the slotPowerOff command and then the slotPowerOn command. On a Brocade 7500 or AP7600 switch, reboot or power cycle the switch. Severity ERROR Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 794
fabric. Recommended Load a firmware version on standby that supports NPIV functionality, using the firmwareDownload Action command. Severity WARNING SWCH-1007 Message Probable Cause , [SWCH-1007], ,, WARNING, , Switch port disabled due to - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 795
is enabled with the port configuration that does not support port swap. Recommended Action Replace the blade with ports that support port swap. Then swap the ports back to the ports default area. Refer to the Fabric OS Administrator's Guide for more information on port swapping. Severity WARNING - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 796
Probable Cause Indicates the standby control processor (CP) does not support Trunk Area functionality, but the switch has some ports with Trunk Area enabled. Recommended Load a firmware version on standby that supports Trunk Area functionality, using the Action firmwareDownload command. Severity - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 797
that all Trunk Areas have been disabled and the configuration file has been updated. Recommended No action is required OS problem or due to file corruption. Recommended Action Restart or power cycle the switch If the message persists, run the firmwareDownload command to update the firmware - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 798
not a supported configuration. Remove the WWN-PID binding and re-enable the port and support links to AG running QOS. Recommended Load a firmware version on the standby CP that supports QOS links to AG, using the Action firmwareDownload command. Severity WARNING 712 Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 799
FMS mode. Probable Cause Indicates the switch has ports with FMS reserved areas (0xFE or 0xFF) which are not supported in FMS mode. Recommended Action This is a normal event; no action is required. Refer to the Fabric OS Administrator's Guide for more information. Severity WARNING Fabric - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 800
102 SWCH-1022 714 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 801
to change chassis configuration> Indicates that on system startup, the option configuration file corresponding to the chassisConfig option read could not be found. This indicates that option is not supported on this platform running this version of the firmware. Fabric OS Message Reference 715 53 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 802
limit has been reached or a restart action has failed. Recommended Use the supportSave command to gather troubleshooting data. Issue a reboot or haFailover Action command to recover the system and limit the traffic disruption. Severity WARNING 716 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 803
Action Run the memShow command to view the switch memory usage. Restart or power cycle the switch. Run the supportFtp command to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL SYSM-1002 Message , [SYSM - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 804
, , Failed to retrieve current chassis configuration option, ret= Probable Cause Indicates there was a failure to read configuration data from the WWN card. Recommended Verify that and restart the CP. Action Severity WARNING 718 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 805
Indicates that the key acquisition for the pool or the container has begun or is complete. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 719 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 806
105 TAPE-1001 720 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 807
switch or the indicated slot. The reason field indicates the cause for generating the dump as one of the following: • PANICDUMP generated by panic dump • WATCHDOG EXPIRED generated by hardware watchdog expiration • MANUAL generated by the tracedump -n command • TRIGGER when triggered by a specific - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 808
supportSave Action command and contact your switch service provider. Severity ERROR TRCE-1006 Message Probable Cause , [TRCE-1006], ,, INFO, , FTP Connectivity Test succeeded to FTP site ' '. Indicates that a connectivity - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 809
communicate trace information to active CP. This message is only applicable to the Brocade 24000 and 48000. Recommended Action Run the haShow command to verify that the supportSave command and contact your switch service provider. Severity WARNING Fabric OS Message Reference 723 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 810
your switch service provider. Severity ERROR TRCE-1011 Message , [TRCE-1011], ,, INFO, , Trace dump manually transferred supportSave command and contact your switch service provider. Severity WARNING 724 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 811
failed login. This occurs if the user name or password is incorrect. Recommended Action This message indicates a typing , it might indicate an unauthorized user trying to gain access to a switch. When Secure mode is enabled on the fabric, the IP address of OS Message Reference 725 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 812
Indicates the track change feature recorded a configuration change for the switch. The track change feature records any change to the configuration file in nonvolatile memory, including a enable the track changes feature. Action Severity INFO 726 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 813
server IP configured correctly. Verify this clock server is accessible to the switch and functional. If the principal or primary FCS does not support the feature, either choose a different switch for the role or reset the clock server to LOCL. Severity INFO Fabric OS Message Reference 727 53 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 814
Service FCS) switch. Another clock server in the list of clock servers configured is being used. This happens when the network time protocol (NTP) query to the current active external clock server fails. Recommended No action is required. Action Severity WARNING 728 Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 815
detected: Port = , should be Probable Cause Indicates the switch detected an inconsistency in the routing database between the routing protocol and the hardware configuration. The first port number displayed is what the hardware has configured and the second port number - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 816
enabled. Probable Cause Indicates the DLS option has been enabled for the switch. This will move existing routes to a new redundant path, when this option has been disabled for the switch. Recommended No action is required. Action Severity INFO 730 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 817
Lossless-DLS option. Probable Cause Indicates the IOD option has been enabled for the switch. This option guarantees in-order delivery of frames during topology changes. Recommended No action Recommended No action is required. Action Severity INFO Fabric OS Message Reference 731 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 818
109 UCST-1027 732 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 819
the specified switch is unreachable because of the TI zone and the fabric configuration incompatibility. Clear all TI zones and refer to the TI zone user manual for instructions on how to create a valid TI zone for your fabric configuration. Severity WARNING Fabric OS Message Reference 733 53 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 820
110 UPTH-1002 734 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 821
Virtual PWWN config file for the switch. Probable Cause Indicates that the configuration file is corrupted or accidently removed. Recommended Restart the switch and download the configuration using the configdownload command. Action Severity ERROR Fabric OS Message Reference 735 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 822
mismatch detected. Probable Cause Indicates that the virtual Port World Wide Name (PWWN) configuration present on the switch is not of the same Fabric OS version. Recommended Converting the virtual PWWN configuration to current Fabric OS version. No action is required. Action Severity INFO - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 823
INFO, , Virtualization services failed to create timer. Probable Cause Indicates failure in virtualization service daemon (vsd) start up because vsd has failed to create a timer. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 737 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 824
111 VS-1008 738 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 825
1002], ,, WARNING, , Missing or Invalid Key file -- HTTPS is configured but could not be started. Probable Cause Indicates the SSL key file is either invalid or absent size of the HTTP log file exceeded the maximum limit. Fabric OS Message Reference 739 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 826
change of IP Address. Probable Cause Indicates the IP address of the switch changed and the HTTP server is restarted. Recommended No action is required. recovery process has failed to restore HTTP services. The problem often results from invalid configuration of SSL certificates, but there can be - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 827
FC Initiator ID>//. Probable Cause Indicates that the FCP exchange has timed out. Recommended If there was an unexpected job failure associated with this event, contact your customer support for Action assistance. Severity ERROR Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 828
>,, INFO, , FTRACE buffer on slot DP has been cleared. Indicates that a CLI command or a support save operation freed the trace buffer back into the FTRACE free pool. 742 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 829
Message , [XTUN-1998], ,, INFO, , FTRACE buffer has been cleared. Probable Cause Indicates that a CLI command or a support save operation freed the trace buffer back into the FTRACE free pool. Recommended No action is required - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 830
-name>, FCIP Tunnel Pri QoS UP. Indicates that the specified quality of service for this tunnel is up. This applies to the data classes only. When the f-class comes online, the tunnel itself is marked as up. 744 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 831
Port (Tunnel) Number> Pri QoS DOWN . Probable Cause Indicates that the specified quality of service has gone down. This applies to the data classes only. If the f-class that the status of an IKEv2 session has changed. Fabric OS Message Reference 745 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 832
No action is required. Action Severity INFO XTUN-2020 Message Probable Cause , [XTUN-2020], ,, INFO, , FCIP Tunnel DELETED (). Indicates that the specified tunnel has been administratively deleted. 746 Fabric - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 833
>, [XTUN-2022], ,, INFO, , FCIP Tunnel MODIFIED (). Probable Cause Indicates that the specified tunnel has been tunnel. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 747 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 834
, [XTUN-2025], ,, INFO, , FCIP Tunnel Circuit MODATTR (). Probable Cause Indicates that the Recommended No action is required. Action Severity INFO 748 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 835
form-factor pluggable (SFP), an incompatible SFP pair, or a faulty cable between peer ports. Recommended Verify if you are using a compatible SFPs on the peer ports. Determine whether the SFPs have Action deteriorated and the Fibre Channel cable is faulty. Replace the SFPs or cable if necessary - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 836
due to Link Reset failure on internal Port S,P(). Probable Cause Indicates that port got re-initialized due to Link Reset failure. Recommended Whenever this error is observed persistently, power cycle the faulted blade. If the problem persists, Action - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 837
114 ZEUS-1016 Recommended Whenever this error is observed persistently, power cycle the faulted blade. If the problem persists, Action replace the blade. Severity WARNING Fabric OS Message Reference 751 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 838
114 ZEUS-1016 752 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 839
number>) which does not exist. Probable Cause Indicates that the port zone member that is targeted for the local switch contains a nonexistent port. The specified port number in the effective zoning configuration (displayed in the error message) is out of range. Recommended Edit the zone database - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 840
The devices are used to specify zone members over separate zones. Recommended If hardware zoning enforcement is preferred, edit the zoning database to have the device zoned Action using only one specification type: WWN or D,I. Severity WARNING ZONE-1007 Message Probable Cause , [ZONE - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 841
maximum number of CAM entries allowed depends on the application-specific integrated circuit (ASIC). Recommended If hardware zoning enforcement is preferred, edit the zoning database to have zoned port IDs Action (PIDs) for that port. Severity WARNING ZONE-1010 Message , [ZONE-1010 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 842
Indicates that the QuickLoop feature is not supported in the current version of Fabric OS. QuickLoop zones are not supported in Fabric OS version 4.x or later. Even if the QuickLoop zoning configuration is enabled on the switch, it will not be supported. Recommended Edit the zone database to remove - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 843
transaction running on the local switches. If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. Severity ERROR Fabric OS Message Reference 757 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 844
operation. This usually occurs if the switch on the other side of the port is busy. Recommended If the problem persists, execute supportFtp (as needed) to set up automatic FTP transfers; then Action execute the supportSave command and contact your switch service provider. Severity INFO ZONE-1024 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 845
name>, Commit zone DB larger than supported - greater allowable limit for the specific switches in your fabric. Severity configuration restored from the flash was faulty. This error will save the faulty zone configuration in the zoned core file directory. Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 846
problem persists, execute the supportFtp command (as needed) to set up automatic FTP Action transfers; then execute the supportSave command and contact your switch service , Switch is in interop mode. (switch, port) members not supported. Probable Cause Indicates the switch is set to - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 847
, , Unable to create : error message . Indicates that the Fabric OS cannot create the zone configuration file. Typically, the zone configuration is too large for the memory available on the switch. Fabric OS Message Reference 761 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 848
that the Fabric OS cannot read the zone configuration file. Typically, the zone configuration is too large for the memory available on the switch. Recommended Reduce the size of the zone database and retry the operation. Action Severity ERROR 762 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 849
-name>, Merged zone database exceeds limit. Probable Cause Indicates that the Fabric OS cannot read the merged zone configuration file. Typically, the zone configuration is too large for the memory available on the switch. Recommended Reduce the size of the zone database and retry the operation - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 850
not support defined database. Probable Cause Indicates that a remote Brocade switch is running a lower version of Fabric OS that does not support the defined database. Recommended Upgrade all the switches to the same firmware version. Action Severity INFO 764 Fabric OS Message Reference 53 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 851
while system initialization. Probable Cause Indicates that there is an Admin Domain (AD) Default Zone conflict. Recommended Action Verify that the default zoning mode for AD0 is set to No Access using was done on purpose. Action Severity INFO Fabric OS Message Reference 765 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 852
zone enabled with Frame Redirection zones. Probable Cause Indicates that frame redirection will not function properly with McDATA default zoning. Recommended Remove frame redirection zones or disable McDATA default zoning. Action Severity WARNING 766 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 853
zone name> has domain running pre FOS6.4.0 firmware. TI member (Domain , Index ) is not supported. Probable Cause Recommended Action Indicates that an unsupported port index(> 511) is present in the TI - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 854
. Recommended Execute the zone --showTIerrors command on the specified switch to report the conflicting Action configuration details. Severity WARNING ZONE-1060 Message , [ZONE- (ISLs) to the specified domain. Action Severity WARNING 768 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 855
Messages 811 •AUDIT IPAD System Messages 813 •AUDIT MS System Messages 815 •AUDIT PMGR System Messages 817 •AUDIT PORT System Messages 819 •AUDIT RAS System Messages 821 •AUDIT SEC System System Messages 869 •AUDIT ZONE System Messages 873 Fabric OS Message Reference 769 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 856
770 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 857
that the F_Ports mapped to an N_Port have changed and the configuration file has been updated. Recommended No action is required. Action the specified Arbitrated Port Loop Address (ALPA) value. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 771 53- - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 858
, , , , Port is connected to a Non-Brocade fabric with Persistent ALPA enabled. Check the admin guide for supported configuration . Probable Cause Indicates that one of the ports is connected to a non-Brocade fabric. Recommended No action is required - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 859
bottleneck on port / - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 860
on this port. Probable Cause Indicates that resources needed to determine whether there is complete credit loss on a VC at this port are in use by port mirroring. Recommended Contact your vendor's customer support for assistance. Action Severity WARNING 774 Fabric OS Message Reference 53 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 861
-location>, , Performed link reset to recover the port credits on slot port . Probable Cause Indicates a credit loss. Recommended The port is recovered. No action is required. Action Severity WARNING Fabric OS Message Reference 775 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 862
117 AN-1013 776 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 863
initiator-details>, , , Certificate not present in this switch in port . Probable Cause Indicates that the public key infrastructure (PKI ". Recommended Retry the secAuthCertificate command. Action Fabric OS Message Reference 777 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 864
; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-3001 Message - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 865
Otherwise the E_Port will form without authentication. Recommended Action If the light on the specified port is off, correct the switch policy configuration on either of the switches using the authUtil command, and then enable the port on the neighboring switch using the portEnable command. If the - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 866
reinitialize authentication using the portDisable and portEnable commands. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity INFO 780 Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 867
, , , , An IPsec/IKE policy was deleted. Probable Cause Indicates that an IPsec or IKE policy was deleted and the configuration file has been updated. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 781 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 868
119 BLS-1003 782 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 869
. Probable Cause Indicates that the CEE shell is ready to accept configuration commands. Recommended No action is required. Action Severity INFO CCFG-1013 that the switch state has changed. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 783 53-1002448 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 870
120 CCFG-1013 784 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 871
: Membernode \\ added to encryption group. Probable Cause Indicates a membernode was added to an encryption group. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 785 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 872
, , , , Event: cryptocfg Status: success, Info: Heartbeat timeout set to . Indicates that the heartbeat timeout value was set. 786 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 873
>, , , Event: cryptocfg Status: success, Info: Membernode unregistered. Probable Cause Indicates a membernode was unregistered. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 787 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 874
if luns are setup for encryption. Recommended Preserve EG name when EG is recreated if luns are setup for encryption. Action Severity INFO 788 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 875
the configuration without disabling the switch was unsuccessful because there are one or more parameters that require the switch to be disabled. Recommended Disable the switch using the switchDisable command and download the configuration. Action Severity WARNING Fabric OS Message Reference 789 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 876
-initiator-details>, , , Fabric Configuration Parameter changed to . Probable Cause Indicates that the fabric configuration parameter value has been changed. Recommended No action is required. Action Severity INFO 790 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 877
>, , Event: cryptocfg Status: success, Info: HA cluster deleted. Probable Cause Indicates a HA cluster was deleted. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 791 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 878
>, [CVLM-3007], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: container \\ created. Indicates a cryptotarget container was created. 792 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 879
cryptocfg Status: success, Info: Manual failback from EE / to EE /. Probable Cause Indicates a manual failback was performed to an engine. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 793 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 880
: cryptocfg Status: success, Info: Lun , attached through Initiator \\, in crypto target container \\ modified. Indicates a LUN in a cryptotarget container was modified. 794 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 881
-location>, , Event: cryptocfg Status: success, Info: Tape pool \\ created. Probable Cause Indicates a tapepool was created. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 795 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 882
Probable Cause AUDIT, , [CVLM-3021], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: Manual rekey all performed. Indicates a complete manual rekey was performed. 796 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 883
>, , Event: cryptocfg Status: success, Info: Transaction aborted. Probable Cause Indicates a transaction abort operation was performed. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 797 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 884
, SECURITY, , , , Event: cryptocfg Status: success, Info: SRDF mode set to . Indicates that the SRDF mode was set. 798 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 885
Recommended No action is required. Action Severity INFO 123 CVLM-3028 Fabric OS Message Reference 799 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 886
123 CVLM-3028 800 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 887
an appropriate fabric name and set it again from any switch. Action Severity WARNING ESS-1010 Message configured fabric name is already used for another partition. Recommended Select a different fabric name and reconfigure. Action Severity WARNING Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 888
124 ESS-1010 802 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 889
. Probable Cause Indicates that an IPsec/IKE policy was deleted and the config file was updated. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 803 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 890
125 FCIP-1003 804 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 891
, , [FICU-1019], INFO, CFG, , , , Switch has been set offline by LP(). Probable Cause Indicates that FMS has disabled the switch. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 805 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 892
-1021], INFO, CFG, , , , Port Addrs () have been UnBlocked by . Probable Cause Indicates that FMS has unblocked the specified ports. Recommended No action is required. Action Severity INFO 806 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 893
that the number of frame types or commands that the port receives has risen above the high boundary. The port has received a small computer system interface (SCSI) with normal operation of the switch. Excessive permanent increases can lead to future problems. Recommended Remove some unwanted files - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 894
Cause AUDIT, , [FW-3001], INFO, CFG, , , , Event: , Status: success, Info: Indicates that Port Fencing was enabled or disabled successfully. 808 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 895
Recommended No action is required. Action Severity INFO FW-3001 127 Fabric OS Message Reference 809 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 896
127 FW-3001 810 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 897
planned, no action is required. If the event was Action not planned, take appropriate action as defined by your enterprise security policy. Severity INFO Fabric OS Message Reference 811 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 898
128 HTTP-1003 812 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 899
], INFO, CFG, , , , Switchname has been successfully changed to . Probable Cause Indicates that a change with the switch name has occured. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 813 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 900
129 IPAD-1002 814 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 901
, Duplicate Fabric Name matching with FID . Probable Cause Indicates that the configured fabric name is already used for another partition. Recommended Select a different fabric name and reconfigure. Action Severity ERROR Fabric OS Message Reference 815 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 902
130 MS-1029 816 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 903
], INFO, LS, , , , Attempt to delete switch succeeded. Probable Cause Indicates that the switch with the specified FID was successfully deleted. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 817 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 904
131 PMGR-1003 818 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 905
], INFO, CFG, , , , Configuration changed for port (ID: ) in No_Module or No_Light state. Probable Cause Indicates the configuration changes were made to an offline port in No_Module or No_Light state. Recommended No action is required. Action - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 906
AUDIT, , [PORT-1009], INFO, CFG, , , , GigE Port (ID: ) has been disabled. Probable Cause Indicates a GigE port has been disabled. Recommended No action is required. Action Severity INFO 820 Fabric OS Message Reference 53-1002448 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 907
>, ,, Audit message class configuration has been changed to . Probable Cause Indicates that the audit event class configuration has been changed. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 821 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 908
133 RAS-2003 822 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 909
, no action is required. If the security mode change was not planned, take appropriate action as defined by your enterprise security policy. Severity INFO Fabric OS Message Reference 823 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 910
been an fabric configurations server (FCS) failover. • A security policy has been activated. • A security policy has been saved. • A security policy has been aborted. • A non-FCS password has changed. your enterprise security policy. Severity INFO 824 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 911
(s) from policy . Probable Cause Indicates a user has removed the specific members from the specified security policy. If you use a wildcard (for example, an asterisk) by your enterprise security policy. Severity INFO Fabric OS Message Reference 825 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 912
], INFO, SECURITY, , , , Event: , Status: success, Info: Reset [] statistics on domain(s) []. Indicates that a user has reset a security statistic on the specified domains. 826 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 913
. Probable Cause Indicates a user has changed the remote authentication dial-in user service (RADIUS) configuration. Recommended Action Verify the RADIUS configuration was changed intentionally. If the RADIUS configuration was intentionally changed, no action is required. If the security event - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 914
Info>. Probable Cause Indicates a user has changed the remote authentication dial-in user service (RADIUS or LDAP) configuration. Recommended Action Verify the RADIUS configuration was intentionally changed. If the RADIUS configuration was intentionally changed, no action is required. If the - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 915
Status: success, Info: Passwdcfg parameters set to default values. Probable Cause Indicates the passwdCfg parameters are set to default values. Recommended Action Verify the security event was by your enterprise security policy. Severity INFO Fabric OS Message Reference 829 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 916
AUDIT, , [SEC-3024], INFO, SECURITY, , , , Event: , Status: success, Info: User account [], password changed. Indicates the user's password was changed. 830 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 917
Name>, Status: success, Info: User account [] added. Role: [], Password [], Home Context [], AD/VF list []. Probable defined by your enterprise security policy. Severity INFO Fabric OS Message Reference 831 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 918
>, , , Event: , Status: success, Info: Probable Cause Indicates the specified secCertUtil operation was performed. Recommended Action Verify Domains>. Indicates that the specified event has occurred. 832 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 919
configuration has changed. Recommended Action Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy. Severity INFO Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 920
-details>, , , Event: ipfilter, Status: failed, Info: Failed to activate . Indicates the specified IP filter policy failed to activate. 834 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 921
host is displayed in the message. Recommended Check for unauthorized access to the switch through the specified protocol connection. Take Action appropriate action as defined by your as defined by your enterprise security policy. Severity INFO Fabric OS Message Reference 835 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 922
, , Info: RBAC permission for a CLI command: is failed. Probable Cause Indicates the user does fipscfg CLI to: . Indicates the status of bootprom access is changed using the fipscfg command. 836 Fabric OS Message Reference 53- - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 923
INFO, SECURITY, Event: , Status: success, Info: . Probable Cause Indicates the specified sshutil operation was performed.. Recommended Action Verify deleted. Indicates that the specified role name has been deleted. Fabric OS Message Reference 837 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 924
, Permission to the RBAC class(es) '' is changed for the Configuration of user-defined roles is uploaded. Probable Cause Indicates the configuration of user-defined roles have been uploaded. Recommended No action is required. Action Severity INFO 838 Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 925
event-initiator-details>, , , Configuration of user-defined roles is downloaded. Probable Cause Indicates the configuration of user-defined roles have been downloaded. in. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 839 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 926
134 SEC-4001 840 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 927
> configuration was reset to default. Probable Cause Indicates that the specified SNMP configuration group was reset to the factory default. Recommended Execute the snmpConfig --show command for the group to view the new SNMP configuration. Action Severity INFO Fabric OS Message Reference 841 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 928
are on port . Probable Cause Indicates the blocked or unblocked status of the port traps on the specified port. Recommended Execute the snmpTraps --show command to view the current status of the port. Action Severity INFO 842 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 929
Status: success, Info: EE in slot registered. Probable Cause Indicates an encryption engine was registered. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 843 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 930
>, , , Event: cryptocfg Status: success, Info: file imported via scp: []:. Indicates a file was imported via SCP protocol. 844 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 931
Status: success, Info: EE in slot zeroized. Probable Cause Indicates an encryption engine was zeroized. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 845 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 932
, , ,,Event: cryptocfg Status: success, Info: Key archive client registered with certificate file \"\". Indicates a KAC certificate was registered. 846 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 933
-location>, , Event: cryptocfg Status: success, Info: Master key exported. Probable Cause Indicates a master key was exported. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 847 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 934
SECURITY, , , , Event: cryptocfg Status: success, Info: Authentication card registered. Certificate label: \"\" Certificate file: \"\". Indicates an authentication card was registered. 848 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 935
cryptocfg Status: success, Info: Authentication card with certificate label \"\" deregistered. Probable Cause Indicates an authentication card was deregistered. Recommended No set. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 849 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 936
], INFO, SECURITY, , , , Event: SPM-EE state changed, Info: EE State: . Indicates an EE state has changed. 850 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 937
: KeyVault Connection Status: , Info:KAC_Connect: . Probable Cause Indicates the status of key vault. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 851 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 938
136 SPM-3029 852 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 939
disruption. Do not fail over or power down the system during firmware upgrade. Run the firmwareDownloadStatus command for the firmwareDownload command has completed successfully and switch firmware has been updated. Recommended Action No INFO Fabric OS Message Reference 853 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 940
CP." "firmwareDownload failed." "firmwareDownload failed due to IPC error." "Unable to check the firmware version on Standby CP due to IPC error." "firmwareDownload failed due to IPC error." "firmwareDownload 0x42 0x43 0x44 0x50 0x51 0x52 0x53 0x54 854 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 941
Standby CP failed to boot up." "Standby CP booted up with new firmware." "Standby CP failed to boot up with new firmware." "firmwareDownload has completed successfully on Standby CP." "firmwareDownload has started on 0x77 0x78 0x79 0x7a 0x7b 0x7c 0x7d Fabric OS Message Reference 855 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 942
. Blade is rebooting with the new firmware." 0xa4 "Blade has rebooted successfully." 0xa5 "New firmware failed to boot up. Please retry firmwareDownload." 0xa6 "firmwareCommit has started on the blade. This may take up to 10 minutes." 0xa7 856 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 943
list file. Check whether the switch is supported by the requested firmware. Also check firmwareDownload help page for service provider for recovery." 0x13 "Out of memory." 0x14 "Failed to download RPM package." 0x15 "Unable to create firmware Fabric OS Message Reference 857 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 944
firmware on the switch may be two releases older than the requested firmware. firmwareDownload supports firmware upgrades within two feature releases (a feature release is indicated by a major number and a minor number, for example, X.Y). The following are major upgrade versions for the Fabric OS - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 945
director-class switch, when firmwareDownload fails, the command will synchronize the firmware on the two partitions of each CP by starting a firmware commit operation. Wait until this operation completes (about 10 minutes) before attempting another firmwareDownload. Fabric OS Message Reference 859 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 946
download the desired version of firmware onto the CPs. Refer to the Fabric OS Administrator's Guide for troubleshooting information. Severity INFO SULB-1010 your switch service provider. Action Severity INFO SULB-1017 Message AUDIT, , [SULB-1017], ERROR, FIRMWARE, - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 947
blade to trigger another firmwareDownload. If the problem persists, contact your switch service provider. Severity ERROR SULB-1020 Message AUDIT, , [SULB-1020], ERROR, FIRMWARE, , , , New firmware failed to boot in slot - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 948
error caused by an unexpected disruption of the firmwareDownload command, for example, by powering the switch off and on in the middle of a firmwareDownload. The error may also be caused by persistent storage hardware failure or by a software error. 862 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 949
. Probable Cause Indicates the firmwareDownload process has completed on the switch. Recommended Run the firmwareShow command to verify the firmware versions. Run the switchShow command to Action make sure the switch is enabled. Severity WARNING Fabric OS Message Reference 863 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 950
the internal image to be relocated again. If the problem persists, Action contact your switch service provider. Severity ERROR SULB-1037 Message AUDIT, , [SULB-1037], ERROR, FIRMWARE, HCL failed. Reboot the switch manually using the reboot command. However, it will - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 951
command to verify the firmware versions. Run the firmwareDownload command again if the firmware is not updated. This will cause the internal image to be relocated again. If the problem persists, contact your switch service provider. Severity WARNING Fabric OS Message Reference 865 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 952
command has completed successfully and switch firmware has been updated. Recommended Action No action is required. The firmwareActivate command has completed as expected. Run the firmwareShow command to verify the firmware versions. Severity INFO 866 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 953
() has been enabled for one or more ports. Probable Cause Indicates that a Trunk Area has been enabled for one or more ports and the config file has been updated. Recommended No action No action is required. Action Severity INFO Fabric OS Message Reference 867 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 954
138 SWCH-1014 868 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 955
option has been enabled. Probable Cause Indicates the DLS option has been enabled for the switch. This will move existing routes to a new redundant path, when this path becomes available. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 869 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 956
with Lossless-DLS option. Probable Cause Indicates the IOD option has been enabled for the switch. This option guarantees in-order delivery of frames during topology changes. Recommended No action may cause higher frame loss during topology changes. 870 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 957
Recommended No action is required. Action Severity INFO 139 UCST-1027 Fabric OS Message Reference 871 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 958
139 UCST-1027 872 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 959
object set. The zone object type variable can be alias, zone member, zone or zone configuration. The string "..." appears at the end of the zone object member list variable if the >\" deleted. Indicates that the specified zone object has been deleted. Fabric OS Message Reference 873 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 960
zone configuration has been disabled. Recommended Verify that the event was planned. If the event was planned, no action is required. If the event was Action not planned, take appropriate action as defined by your enterprise security policy. Severity INFO 874 Fabric OS Message Reference 53 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 961
Name>, Status: success, Info: Zone configuration \"\" enabled. . Probable Cause Indicates that the specified zone configuration has been enabled. Recommended Verify that the object has been copied to a new zone object. Fabric OS Message Reference 875 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 962
admin domain (AD) has been activated. Recommended Verify that the event was planned. If the event was planned, no action is required. If the event was Action not planned, take appropriate action as defined by your enterprise security policy. Severity INFO 876 Fabric OS Message Reference - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 963
Info: All AD definitions cleared. Probable Cause Indicates that all AD definitions and all zone configurations under them have been cleared. Recommended Verify that the event was planned. If the event your enterprise security policy. Severity INFO Fabric OS Message Reference 877 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 964
from \"\". Indicates that the specified AD member or members have been removed from the AD. 878 Fabric OS Message Reference 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 965
: , Status: success, Info: Current AD configuration saved to flash. Probable Cause Indicates that the current AD configuration has been saved to flash. Recommended Verify that the event by your enterprise security policy. Severity INFO Fabric OS Message Reference 879 53-1002448-01 - HP Brocade 8/24c | Brocade Fabric OS Message Reference - Supporting Fabric OS v7 - Page 966
, no action is required. If the event was Action not planned, take appropriate action as defined by your enterprise security policy. Severity INFO 880 Fabric OS Message Reference 53-1002448-01
53-1002448-01
15 December 2011
®
Fabric OS
Message Reference
Supporting Fabric OS v7.0.1