HP ML150 HP ProLiant ML150 G6 Server Maintenance and Service Guide - Page 36
Hard drives, Non-hot-plug hard drives
UPC - 884420743644
View all HP ML150 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
Hard drives The server uses a HDD cage assembly that supports four hard drives in either a non-hot-plug or hotplug configuration. The server supports SATA or SAS hard drives. SATA hard drives are supported directly by the system board. SAS hard drives require an SATA/SAS PCIe expansion card. For more information about installing PCIe expansion cards, see "Expansion cards." Non-hot-plug hard drives Servers shipped in a non-hot-plug drive configuration include a non-hot-plug HDD cage installed in the upper bay area (bays 1 through 4). Removing/replacing a non-hot-plug hard drive To remove and replace a non-hot-plug hard drive: 1. Power down the server. 2. Disconnect the power cord(s). 3. Remove the access panel and front bezel as described in the section titled "System covers." 4. Disconnect the power and data cables from all hard drives (Figure 3-9, 1). 5. Remove the 4 mounting screws from the HDD cage (Figure 3-9, 2) and slide the HDD cage out from the server chassis (Figure 3-9, 3). Figure 3-9 Removing a non-hot-plug HDD cage Removal and replacement procedures 36