HP ML150 HP ProLiant ML150 G6 Server Maintenance and Service Guide - Page 89

Table, Description, Status, Front and Rear Panel Components

Page 89 highlights

Table 5-1 Front and Rear Panel Components Item Description Item 11 NIC1 LED 22 Description UID Table 5-2 Front and rear panel LED indicator status LED Status System power Green Amber System health Off Red (blinking) NIC1 NIC2 Hard drive activity IPMI/NIC activity IPMI/NIC link UID Amber (blinking) Green Off Green (blinking) Green off Green (blinking) Green off Green (blinking) Off Green (blinking) Green (steady) Off Off Green Amber Blue Blue (blinking) Off Description System is on System is in standby, System is off, but has AC power System has no AC power Critical system failure detected (processor, memory, regulator, thermal event, fan, NMI) System degraded System is on and no failures detected System is off and there is no failures prior to system power off Network activity detected Linked to the network Network not active Network activity detected Linked to the network Network not active Drive activity No drive activity Linked and activity on the network Linked to the network No connection No connection 100 Mb/speed 1 Gb/speed Identification System is being remotely managed System is off Components, Switches, and Indicators 89

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106

Components, Switches, and Indicators
89
Table
5
-1
Front and Rear Panel Components
Item
Description
Item
Description
11
NIC1 LED
22
UID
Table
5
-2
Front and rear panel LED indicator status
LED
Status
Description
Green
System is on
Amber
System is in standby, System is off,
but has AC power
System power
Off
System has no AC power
Red (blinking)
Critical system failure detected
(processor, memory, regulator,
thermal event, fan, NMI)
Amber (blinking)
System degraded
Green
System is on and no failures
detected
System health
Off
System is off and there is no failures
prior to system power off
Green (blinking)
Network activity detected
Green
Linked to the network
NIC1
off
Network not active
Green (blinking)
Network activity detected
Green
Linked to the network
NIC2
off
Network not active
Green (blinking)
Drive activity
Hard drive activity
Off
No drive activity
Green (blinking)
Linked and activity on the network
Green (steady)
Linked to the network
IPMI/NIC activity
Off
No connection
Off
No connection
Green
100 Mb/speed
IPMI/NIC link
Amber
1 Gb/speed
Blue
Identification
Blue (blinking)
System is being remotely managed
UID
Off
System is off