System fans, Fan holder assembly removal and replacement
UPC - 884420743644
View all HP ML150 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 55 highlights
System fans The server includes 4 system fan assemblies; 3 front fan holder assembly and a rear fan assembly. Fan holder assembly removal and replacement To remove the front fan/PCI card holder assembly: 1. Power down the server. 2. Disconnect the power cord(s). 3. Unlock the server if necessary and remove the access panel as described in the section "System covers." 4. Remove all full-size expansion cards as described in the section "Removing an expansion card" if necessary. 5. On the front fan holder assembly, press the thumb lever down slightly (Figure 3-33,1 ) and slide the assembly a short distance toward the top of the server chassis (Figure 3-33,2). Figure 3-33 Removing the front fan/PCI card holder assembly 6. Rotate the fan assembly toward the rear of the chassis and lift away from the mounting slots, but not completely from the chassis. 7. While supporting the fan holder assembly with one hand, disconnect the fan cable from system board connector (Figure 3-33,3). 8. Remove the front fan holder assembly the chassis. End of procedure. Removal and replacement procedures 55