HP Neoware e90 Neoware Thin Client - Thintune Operating System Manual - Page 97

Rescue System - upgrades

Page 97 highlights

Please make sure that „enable comX portmapping" is checked. Now either configure the terminal emulation or the Telnet Client. To be independent from the IP-address of the terminal set the THINTUNE-IP to its loopback address which is 127.0.0.1. As the port address either choose 9101 or that port number which is configured in the portmapper. 10.5 Rescue System All THINTUNE Thin Clients are capable of an internal rescue system which enables you to still operate your THINTUNE TC even if the downloaded firmware is corrupted. Corruption at firmware basically will happen whenever a terminal is powered off during upgrade process. THINTUNE OS which is the THINTUNE OS basically will be loaded by a bootloader at time of start up. If corrupted firmware is detected the bootloader will take care to start the rescue system from a TFTP Server. To use the rescue system please make sure to meet following requirements. DHCP Server TFTP Server Rescue Files Firmwareserver The TFTP-server can be requested at [email protected]. The Firmwareserver can be downloaded at www.thintune.de. The DHCP-server is included in Windows Server OS. 96

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99

96
Please make sure that „enable comX portmapping“ is checked.
Now either configure the terminal emulation or the Telnet Client. To be independent from the IP-address of the
terminal set the THINTUNE-IP to its loopback address which is 127.0.0.1. As the port address either choose 9101
or that port number which is configured in the portmapper
.
10.5 Rescue System
All THINTUNE Thin Clients are capable of an internal rescue system which enables you to still operate your
THINTUNE TC even if the downloaded firmware is corrupted. Corruption at firmware basically will happen whenever
a terminal is powered off during upgrade process.
THINTUNE OS which is the THINTUNE OS basically will be loaded by a bootloader at time of start up. If corrupted
firmware is detected the bootloader will take care to start the rescue system from a TFTP Server. To use the rescue
system please make sure to meet following requirements.
DHCP Server
TFTP Server
Rescue Files
Firmwareserver
The TFTP-server can be requested at [email protected]
. The Firmwareserver can be downloaded at
www.thintune.de