IBM HC10 Service Guide - Page 62
IBM HC10 - BladeCenter - 7996 Manual
UPC - 883436017671
View all IBM HC10 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 62 highlights
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, "Parts listing, Type 7996," on page 11 to determine which components are CRUs and which components are FRUs. v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Error code Description Action 602 Invalid diskette boot record. 1. Check the function of the shared BladeCenter unit resources (see "Solving shared BladeCenter resource problems" on page 75). 2. Make sure the diskette works with another blade workstation. 3. (Trained service technician only) Replace the system board assembly 1162 Configuration change has occurred. 1. Run the Configuration/Setup Utility program and change the resources assigned to the serial port. 2. Check the function of the shared BladeCenter unit resources (see "Solving shared BladeCenter resource problems" on page 75). 3. (Trained service technician only) Replace the system board assembly 1600 BMC failure. Shutdown and remove the blade workstation from the BladeCenter unit, wait 30 seconds; then, reinstall the blade workstation in the BladeCenter unit and restart it. If the problem persists, perform the following tasks in the order shown, restarting the blade workstation each time: 1. Update the BMC firmware. 2. (Trained service technician only) Replace the system board assembly. 1601 BMC is not responding. Shutdown and remove the blade workstation from the BladeCenter unit, wait 30 seconds; then, reinstall the blade workstation in the BladeCenter unit and restart it. If the problem persists, perform the following tasks in the order shown, restarting the blade workstation each time: 1. Update the BMC firmware. 2. (Trained service technician only) Replace the system board assembly. 1762 Hard disk configuration changed 1. Run the Configuration/Setup Utility program, make sure that the hard disk drive configuration is correct, and save the settings. 2. Reseat the hard disk drive. 3. Replace the following components one at a time, in the order shown, restarting the blade workstation each time: a. Hard disk drive b. (Trained service technician only) System board assembly 46 BladeCenter HC10 Type 7996: Problem Determination and Service Guide