I/O-expansion

Page 63 highlights

v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, "Parts listing, Type 7996," on page 11 to determine which components are CRUs and which components are FRUs. v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Error code Description Action 1801 No more ROM available. 1. Run the Configuration/Setup Utility program and make sure that ROM resource settings are correct. 2. Remove each I/O-expansion card one at a time, restarting the blade workstation each time, until the problem is isolated. 3. Replace the following components one at a time, in the order shown, restarting the blade workstation each time: a. Failed I/O-expansion card b. (Trained service technician only) System board assembly 1802 No more I/O space available. 1. Run the Configuration/Setup Utility program and make sure that I/O resource settings are correct. 2. Remove each I/O-expansion card one at a time, restarting the blade workstation each time, until the problem is isolated. 3. Replace the following components one at a time, in the order shown, restarting the blade workstation each time: a. Failed I/O-expansion card b. (Trained service technician only) System board assembly 1803 No more extended memory. 1. Run the Configuration/Setup Utility program and make sure that extended memory settings are correct. 2. Remove each I/O-expansion card one at a time, restarting the blade workstation each time, until the problem is isolated. 3. Replace the following components one at a time, in the order shown, restarting the blade workstation each time: a. Failed I/O-expansion card b. (Trained service technician only) System board assembly Chapter 5. Diagnostics 47

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114

v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Type
7996,”
on
page
11
to
determine
which
components
are
CRUs
and
which
components
are
FRUs.
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
1801
No
more
ROM
available.
1.
Run
the
Configuration/Setup
Utility
program
and
make
sure
that
ROM
resource
settings
are
correct.
2.
Remove
each
I/O-expansion
card
one
at
a
time,
restarting
the
blade
workstation
each
time,
until
the
problem
is
isolated.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
blade
workstation
each
time:
a.
Failed
I/O-expansion
card
b.
(Trained
service
technician
only)
System
board
assembly
1802
No
more
I/O
space
available.
1.
Run
the
Configuration/Setup
Utility
program
and
make
sure
that
I/O
resource
settings
are
correct.
2.
Remove
each
I/O-expansion
card
one
at
a
time,
restarting
the
blade
workstation
each
time,
until
the
problem
is
isolated.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
blade
workstation
each
time:
a.
Failed
I/O-expansion
card
b.
(Trained
service
technician
only)
System
board
assembly
1803
No
more
extended
memory.
1.
Run
the
Configuration/Setup
Utility
program
and
make
sure
that
extended
memory
settings
are
correct.
2.
Remove
each
I/O-expansion
card
one
at
a
time,
restarting
the
blade
workstation
each
time,
until
the
problem
is
isolated.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
blade
workstation
each
time:
a.
Failed
I/O-expansion
card
b.
(Trained
service
technician
only)
System
board
assembly
Chapter
5.
Diagnostics
47