Power, error, messages
UPC - 883436017671
View all IBM HC10 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 79 highlights
Power error messages Power to the blade workstation is provided by shared BladeCenter unit resources. See the following table and "Solving shared BladeCenter resource problems" on page 75. v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, "Parts listing, Type 7996," on page 11 to determine which components are CRUs and which components are FRUs. v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Message Action System Power Good fault 1. Reseat the blade workstation. 2. Check the function of the shared BladeCenter unit resources (see "Solving shared BladeCenter resource problems" on page 75). 3. (Trained service technician only) Replace the system board assembly. VRD Power Good fault 1. Reseat the blade workstation. 2. Check the function of the shared BladeCenter unit resources (see "Solving shared BladeCenter resource problems" on page 75). 3. (Trained service technician only) Replace the system board assembly. System over recommended voltage for +12v. Informational only. Note: If the problem persists, perform the following tasks. 1. Reseat the blade workstation. 2. Check the function of the shared BladeCenter unit resources (see "Solving shared BladeCenter resource problems" on page 75. 3. (Trained service technician only) Replace the system board assembly. System over recommended voltage for +3.3v. Informational only. Note: If the problem persists, perform the following tasks. 1. Reseat the blade workstation. 2. Check the function of the shared BladeCenter unit resources (see "Solving shared BladeCenter resource problems" on page 75. 3. (Trained service technician only) Replace the system board assembly. System over recommended 5V fault. Informational only. Note: If the problem persists, perform the following tasks. 1. Reseat the blade workstation. 2. Check the function of the shared BladeCenter unit resources (see "Solving shared BladeCenter resource problems" on page 75. 3. (Trained service technician only) Replace the system board assembly. System under recommended voltage for +12v. Informational only. Note: If the problem persists, perform the following tasks. 1. Reseat the blade workstation. 2. Check the function of the shared BladeCenter unit resources (see "Solving shared BladeCenter resource problems" on page 75. 3. (Trained service technician only) Replace the system board assembly. Chapter 5. Diagnostics 63