Lexmark T632 Service Manual - Page 214
System board installation, Handling ESD, sensitive parts
View all Lexmark T632 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 214 highlights
4060-xxx System board installation Note: The replacement system board assembly contains a communications board connected to the system board. To install, you need to separate the boards. Warning: Observe all ESD precautions while handling ESD-sensitive parts. See "Handling ESD- sensitive parts" on page 4-1. 1. Flex the communications board to separate the boards. 2. For non-network models, connect the communications board bracket to the communication board with two screws (A). A 3. Clip the communications board shield ground clip on the frame and insert the communications card into the interconnect card slot. 4. Replace the communications board shield mounting screw to connect the bracket to the frame. 5. Insert the communications board mounting screw. 6. Install the system board. 7. Insert the USB screw. 8. Replace the five mounting screws. 9. Replace the features/options and reconnect all cables. 4-60 Service Manual