Lock release, Press the fusing upper and lower heat, rollers and remove the process
View all Sharp AR M550N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
D. Lock release Lock position 1 No. 2/3 mirror base lock screw 2 Tray rotation plate fixing material (1) No. 2/3 mirror base lock release Remove the No. 2/3 mirror base fixing screw and the label of note for unpacking on the left side. E. Press the fusing section (upper and lower heat rollers) and remove the process separation pawl fixing block. 1) Pull the knob on the left door to pull out the left door. 2 (2) Tray rotation release plate lock release Remove the paper feed tray rotation plate fixing screw and the label of note for tray. [Tray 1, Tray 2] 2) Turn the pressing screw in the fusing section as shown in the figure below (fully loosen it) to press the heat roller. [Tray 3, Tray 4] 3) Remove the separation pawl fixing block from the process unit. 4) Replace the left door. AR-M550/M620/M700 INSTALLATION MANUAL (AR-M550/M620/M700) 1 - 5