HP StorageWorks 4000s NAS 4000s and 9000s Administration Guide - Page 67

Storage Configuration Overview, Array Management, Disks, Array Configuration Utility

Page 67 highlights

Disk Management Storage Configuration Overview Physical disks can be arranged as RAID arrays for fault tolerance and enhanced performance, then segmented into logical disks of appropriate sizes for particular storage needs. These logical disks then become the volumes that appear as drives on the NAS server. Note: This type of configuration may not apply to all supported SANs and serves only as an example. The following steps are an example of a storage configuration using an HP StorageWorks MSA1000. Step 1: Create Disk Arrays 1. Click Array Management on the Disks tab. 2. Click Array Configuration Utility and log in to the management page in another browser window. The Array Configuration Utility will start. 3. Select the proper array controller in the left pane of the interface before beginning array configuration. Some NAS systems are equipped with array controllers for both internal and external storage. Consult the Help available in ACU for details on creating arrays, if necessary. Step 2: Create Logical Disks from the Array Space From the ACU: 1. Select a previously created array. 2. Click Create Logical Drive from the right pane of the ACU. 3. Complete the logical drive creation wizard to designate some or all of the array space as a logical disk. Depending on how many physical disks are included in the array, several different types of logical disks are possible. Consult the ACU Help for details on creating logical disk drives. Step 3: Verify newly created logical disks 1. Click Disks on the Disk tab. 2. Verify that disks matching the newly created sizes are displayed. 3. Click on Initialize Disk to initialize the Disk. Note: By default the disk is basic. Click Convert Disk to make the disk dynamic. NAS 4000s and 9000s Administration Guide 67

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246

Disk Management
67
NAS 4000s and 9000s Administration Guide
Storage Configuration Overview
Physical disks can be arranged as RAID arrays for fault tolerance and enhanced performance,
then segmented into logical disks of appropriate sizes for particular storage needs. These
logical disks then become the volumes that appear as drives on the NAS server.
Note:
This type of configuration may not apply to all supported SANs and serves only as an
example.
The following steps are an example of a storage configuration using an HP StorageWorks
MSA1000.
Step 1: Create Disk Arrays
1.
Click
Array Management
on the
Disks
tab.
2.
Click
Array Configuration Utility
and log in to the management page in another browser
window.
The Array Configuration Utility will start.
3.
Select the proper array controller in the left pane of the interface before beginning array
configuration. Some NAS systems are equipped with array controllers for both internal
and external storage.
Consult the Help available in ACU for details on creating arrays, if necessary.
Step 2: Create Logical Disks from the Array Space
From the ACU:
1.
Select a previously created array.
2.
Click
Create Logical Drive
from the right pane of the ACU.
3.
Complete the logical drive creation wizard to designate some or all of the array space as a
logical disk.
Depending on how many physical disks are included in the array, several different types of
logical disks are possible. Consult the ACU Help for details on creating logical disk drives.
Step 3: Verify newly created logical disks
1.
Click
Disks
on the
Disk
tab.
2.
Verify that disks matching the newly created sizes are displayed.
3.
Click on
Initialize Disk
to initialize the Disk.
Note: