HP Xw9400 HP xw9400 Workstation - Service and Technical Reference Guide - Page 20

Environmental specifications, PCI card slot power specification, Temperature, Operating, Non-operating - memory slots

Page 20 highlights

Environmental specifications This section describes environmental specifications of your workstation. Temperature Humidity Altitude Shock Vibration Operating: 5 to 35°C (40 to 95°F) Non-operating: -40 to 60°C (-40 to 140°F) NOTE: Derate by one degree C (1.4 degrees F) for every 305m (1,000 ft.) altitude over 1,524m (5,000 ft.). Operating: 8 to 85% RH, non-condensing Non-operating: 8 to 90% RH, non-condensing Operating: 0 to 3,048m (10,000 ft.) Non-operating: 0 to 9,144m (30,000 ft.) Operating: ½-sine: 40g, 2-3ms Non-operating: ● ½-sine: 160 cm/s, 2-3ms (~100g) ● square: 422 cm/s, 20g NOTE: Values represent individual shock events and do not indicate repetitive shock events. Operating random: 0.5g (rms), 5-300 Hz Non-operating random: 2.0g (rms), 10-500 Hz NOTE: Values do not indicate continuous vibration. PCI card slot power specification Table 1-8 PCI and PCI Express slot power specifications Slot# Slot Type Slot Power (Maximum) 1 PCI Express x16 (x8) 2 PCI Express x16 graphics 25W* 150W** 3 PCI 32 bit, 33 MHz 4 PCI Express x16 (x8) 5 PCI Express x16 graphics 6 PCI-X 100 25W* 25W* 150W** 25W* 7 PCI-X 100/133 25W* * In addition to these slot power specifications, the overall power consumption of the system (including I/O cards, processor, and memory) must not exceed the maximum ratings of the system power supply. See Power supply specifications on page 8 for details. ** Includes 75 W maximum from the system board connector, and 75 W maximum from the auxiliary graphics power connector. 10 Chapter 1 Product overview ENWW

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221

Environmental specifications
This section describes environmental specifications of your workstation.
Temperature
Operating
: 5 to 35°C (40 to 95°F)
Non-operating
: -40 to 60°C (-40 to 140°F)
NOTE:
Derate by one degree C (1.4 degrees F) for every 305m
(1,000 ft.) altitude over 1,524m (5,000 ft.).
Humidity
Operating
: 8 to 85% RH, non-condensing
Non-operating
: 8 to 90% RH, non-condensing
Altitude
Operating:
0 to 3,048m (10,000 ft.)
Non-operating
: 0 to 9,144m (30,000 ft.)
Shock
Operating
: ½-sine: 40
g
, 2-3ms
Non-operating
:
½-sine: 160 cm/s, 2-3ms (~100
g
)
square: 422 cm/s, 20
g
NOTE:
Values represent individual shock events and do not
indicate repetitive shock events.
Vibration
Operating random
: 0.5
g
(rms), 5-300 Hz
Non-operating random
: 2.0
g
(rms), 10-500 Hz
NOTE:
Values do not indicate continuous vibration.
PCI card slot power specification
Table 1-8
PCI and PCI Express slot power specifications
Slot#
Slot Type
Slot Power (Maximum)
1
PCI Express x16 (x8)
25W*
2
PCI Express x16 graphics
150W**
3
PCI 32 bit, 33 MHz
2
5
W*
4
PCI Express x16 (x8)
25W*
5
PCI Express x16 graphics
150W**
6
PCI-X 100
25W*
7
PCI-X 100/133
25W*
* In addition to these slot power specifications, the overall power consumption of the system (including I/O cards, processor,
and memory) must not exceed the maximum ratings of the system power supply. See
Power supply specifications
on page
8
for details.
** Includes 75 W maximum from the system board connector, and 75 W maximum from the auxiliary graphics power connector.
10
Chapter 1
Product overview
ENWW