HP rp7440 nPartition Administrator's Guide, Second Edition - Page 247
Specifying Remote Management Options to Commands, command report cabinet 0, bay 1, chassis 3
View all HP rp7440 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 247 highlights
Example A-1 I/O Specification Formats for Cabinets, Bays, and Chassis # parstatus -I 1 [Chassis] Core Connected Par Hardware Location Usage IO To Num cab0,bay0,chassis0 absent - - - cab0,bay0,chassis1 absent - - - cab0,bay0,chassis2 absent - - - cab0,bay0,chassis3 inactive yes cab0,cell4 - cab0,bay1,chassis0 absent - - - cab0,bay1,chassis1 absent - - - cab0,bay1,chassis2 absent - - - cab0,bay1,chassis3 active yes cab0,cell0 0 cab1,bay0,chassis0 absent - - - cab1,bay0,chassis1 inactive - - - cab1,bay0,chassis2 absent - - - cab1,bay0,chassis3 absent - - - cab1,bay1,chassis0 absent - - - cab1,bay1,chassis1 absent - - - cab1,bay1,chassis2 absent - - - cab1,bay1,chassis3 active yes cab1,cell2 1 cab8,bay0,chassis1 inactive - - - cab8,bay0,chassis3 active yes cab0,cell2 0 cab8,bay1,chassis1 inactive yes cab1,cell0 - cab8,bay1,chassis3 inactive - - - cab8,bay2,chassis1 absent - - - cab8,bay2,chassis3 absent - - - cab8,bay3,chassis1 absent - - - cab8,bay3,chassis3 absent - - - # rad -q 2 Slot 0-1-3-0 0-1-3-1 0-1-3-2 0-1-3-3 0-1-3-4 0-1-3-5 0-1-3-6 0-1-3-7 0-1-3-8 0-1-3-9 0-1-3-10 0-1-3-11 8-0-3-0 8-0-3-1 8-0-3-2 8-0-3-3 8-0-3-4 8-0-3-5 8-0-3-6 8-0-3-7 8-0-3-8 8-0-3-9 8-0-3-10 8-0-3-11 # Path 0/0/0 0/0/1/0 0/0/2/0 0/0/3/0 0/0/4/0 0/0/6/0 0/0/14/0 0/0/12/0 0/0/11/0 0/0/10/0 0/0/9/0 0/0/8/0 2/0/0 2/0/1/0 2/0/2/0 2/0/3/0 2/0/4/0 2/0/6/0 2/0/14/0 2/0/12/0 2/0/11/0 2/0/10/0 2/0/9/0 2/0/8/0 Bus Speed Power Occupied 0 33 On Yes 8 33 On No 16 33 On No 24 33 On No 32 33 On No 48 33 On Yes 112 33 On No 96 33 On No 88 33 On Yes 80 33 On No 72 33 On No 64 33 On No 0 33 On Yes 8 33 On No 16 33 On No 24 33 On No 32 33 On No 48 33 On No 112 33 On Yes 96 33 On No 88 33 On No 80 33 On No 72 33 On No 64 33 On No Suspended No N/A N/A N/A N/A No N/A N/A No N/A N/A N/A No N/A N/A N/A N/A N/A No N/A N/A N/A N/A N/A Driver(s) Capable No N/A N/A N/A N/A Yes N/A N/A Yes N/A N/A N/A No N/A N/A N/A N/A N/A Yes N/A N/A N/A N/A N/A 1 The parstatus -I command reports cabinet 0, bay 1, chassis 3 as cab0,bay1,chassis3. 2 The rad -q command and olrad -q command report cabinet 0, bay 1, chassis 3 as 0-1-3. Specifying Remote Management Options to Commands Two sets of remote management options are supported by the Enhanced nPartition Commands: Specifying Remote Management Options to Commands 247