HP rp7440 nPartition Administrator's Guide, Second Edition - Page 262

fruled Command

Page 262 highlights

fruled Command The fruled command blinks hardware attention indicators (LEDs) or turns them off. This command can control the cell attention LEDs in all cell-based servers, as well as the I/O chassis LEDs on Superdome servers. The fruled command also can start and stop blinking the cabinet number LCDs on HP Superdome compute cabinets and I/O expansion cabinets. Refer to the fruled(1) manpage for details. Synopsis fruled [-f|-o] [-B] -c cell [-c...] fruled [-f|-o] [-B] -i IOchassis [-i...] fruled [-f|-o] -b cabinet [-b...] fruled [-f] -C [-l cabinet] [-l...] fruled [-f] -I [-l cabinet] [-l...] Enhanced nPartition Commands Notes • The -u... -h... set of options may be specified to cause the command to send its management request using WBEM to an nPartition other than the local nPartition (but can also be used as a "loopback access" to the local nPartition). • The -g... -h... options may be specified to cause the command to send its management request using IPMI over LAN to a service processor in another server complex (but can also be used as a "loopback access" to the service processor in the local complex). The -u and -g options are mutually exclusive. Options -f Turn off specified attention LED(s). This is the default. The -f and -o options are mutually exclusive. -o Start blinking the specified attention LED(s). The -o option is unavailable with -C or -I. -B Start or stop blinking the cabinet number LCD of the cabinet that contains the cell or I/O chassis. The -B option is only available with -c and -i. -c cell -i IOchassis -b cabinet -C -l cabinet -u username -g Blink or turn off the specified cell attention LED. cell can be specified either in the local (cabinet/slot) or global (cell_ID) format. Blink or turn off the specified IOchassis attention LED. Start or stop blinking the cabinet number LCD of the specified cabinet. Turn off all cell attention LEDs. Limit the scope of the -C or -I option to a given cabinet. Enhanced nPartition Commands only. Specifies the account and authorization to access an nPartition other than the local nPartition. The -h option is required if this option is used. username specifies a configured user name on the target nPartition. Enhanced nPartition Commands only. Allows access to the complex specified by the -h option. The accessed complex is then considered the target complex. Access is through the service processor LAN port.The -h option is required if this option is used. 262 nPartition Commands

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266

fruled Command
The
fruled
command blinks hardware attention indicators (LEDs) or turns them off.
This command can control the cell attention LEDs in all cell-based servers, as well as the I/O
chassis LEDs on Superdome servers. The
fruled
command also can start and stop blinking the
cabinet number LCDs on HP Superdome compute cabinets and I/O expansion cabinets.
Refer to the
fruled
(1) manpage for details.
Synopsis
fruled [-f|-o] [-B] -c cell [-c...]
fruled [-f|-o] [-B] -i IOchassis [-i...]
fruled [-f|-o] -b cabinet [-b...]
fruled [-f] -C [-l cabinet] [-l...]
fruled [-f] -I [-l cabinet] [-l...]
Enhanced nPartition Commands Notes
The
-u... -h...
set of options may be specified to cause the command to send its
management request using WBEM to an nPartition other than the local nPartition (but can
also be used as a "loopback access" to the local nPartition).
The
-g... -h...
options may be specified to cause the command to send its management
request using IPMI over LAN to a service processor in another server complex (but can also
be used as a "loopback access" to the service processor in the local complex).
The
-u
and
-g
options are mutually exclusive.
Options
-f
Turn off specified attention LED(s). This is the default.
The
-f
and
-o
options are mutually exclusive.
-o
Start blinking the specified attention LED(s). The
-o
option is
unavailable with
-C
or
-I
.
-B
Start or stop blinking the cabinet number LCD of the cabinet
that contains the cell or I/O chassis.
The
-B
option is only available with
-c
and
-i
.
-c
cell
Blink or turn off the specified
cell
attention LED.
cell
can be specified either in the local (
cabinet/slot
) or global
(
cell_ID
) format.
-i
IOchassis
Blink or turn off the specified
IOchassis
attention LED.
-b
cabinet
Start or stop blinking the cabinet number LCD of the specified
cabinet
.
-C
Turn off all cell attention LEDs.
-l
cabinet
Limit the scope of the
-C
or
-I
option to a given
cabinet
.
-u
username
Enhanced nPartition Commands only. Specifies the account
and authorization to access an nPartition other than the local
nPartition.
The
-h
option is required if this option is used.
username
specifies a configured user name on the target
nPartition.
-g
Enhanced nPartition Commands only. Allows access to the
complex specified by the
-h
option. The accessed complex is
then considered the target complex. Access is through the
service processor LAN port.The
-h
option is required if this
option is used.
262