slide the roller onto the right pick roller shaft.
View all Konica Minolta Kodak Ngenuity 9090DB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 44 highlights
Always remove the rollers from the scanner for cleaning to ensure best results. 1. Turn off the scanner and open the transport cover. 2. Remove the pick roller by rotating the blue pick roller release lever up, push the pick roller to the right and rotate it out of position. 3. Using the cleaning wipe, scrub the roller tires in a side-to-side motion, Rotate the roller to clean the entire surface. 4. Re-install the clean pick roller. • With the pick roller positioned so the dots are facing the left side, slide the roller onto the right pick roller shaft. • Holding on to the roller, rotate the pick roller shaft down and slide the roller all the way to the left. The right side of the roller should be clear of the pick roller release lever. • Bring the pick roller release lever down and snap it into place. A-61662 April 2010 5-5