Konica Minolta Kodak Ngenuity 9090DB User Guide - Page 51
Cleaning the transport, Operator Utility.
View all Konica Minolta Kodak Ngenuity 9090DB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 51 highlights
Cleaning the transport Over time, the transport will become dirty and may feed documents erratically or skew the documents as they enter the scanner. To prevent erratic feeding, clean the transport every 50,000 pages or as needed. NOTE: It is recommended that you clean the imaging guides again after cleaning the transport with a transport cleaning sheet. 1. Establish communication between the scanner and the Ngenuity Operator Utility. 2. Verify that one of the Custom Functions is set to Feed Test Batch. 3. Press F1 or F2 key depending on which key is assigned to "Feed Test Batch". This will start the scanner transport. By default, the F1 key is assigned the Feed Test Batch function. 4. Feed the transport cleaning sheet in landscape orientation into the scanner transport. 5. Observe the cleaning sheet, and run it through the transport again, changing its position slightly each time, until the tires leave no dark streaks. 6. Turn the transport cleaning sheet over and run it through the scanner transport two times. 7. Press and hold the Pause/Stop button (2-3 seconds) until the scanner stops running. 8. Press the Clear/Restart button. 9. When finished, discard the transport cleaning sheet. After running the cleaning sheet, inspect the imaging guides. It may be necessary to clean off any residue from the cleaning sheet that may be on the imaging guides. 5-12 A-61662 April 2010