Sony HVR1500A Product Manual (HVE-1500A Operating Manuals) - Page 101
Error messages, Error code classification
View all Sony HVR1500A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 101 highlights
Error messages This unit is provided with a self-diagnostic function that detects internal abnormalities. When it detects an abnormality, it outputs an error message to the monitor screen and indicates an error code in the time counter display. Note To display error messages on the monitor screen, connect the monitor to the (SUPER) CPST connector, and set the CHARA. DISPLAY menu item (see page 77) to ON (factory default setting). ERROR AN ERROR HAS BEEN DETECTED. INFORM SERVICE OF FOLLOWING CODE: 02-603 PRESS EJECT KEY TO EJECT TAPE. Monitor screen Error message Error code Direction Error code Error02-603 Time counter display Error code classification 0X-XXX 2X-XXX 3X-XXX 9X-XXX Appears when a servo or tape transport related error is detected 02- XXX Fault in tape or reel etc. 06- XXX Fault in tension 07- XXX Fault in capstan 08- XXX Fault in drum 09- XXX Fault in loading Appears when a mechanical control error is detected 20-XXX Fault in cassette compartment 21-XXX Fault in reel shift 22-XXX Fault in head cleaner Appears when a sensor fault is detected Appears when an error is detected in the CPU peripheral system or IC control communications When an error message appears, follow the instructions on the monitor screen for resolving the problem. When an error message persists, contact your Sony dealer or a Sony service representative. 101 Troubleshooting Chapter 8 Maintenance and Troubleshooting