Dell PowerConnect 8100 Release Notes - Page 74
Data Center - 4.2.0.4 - dcb
View all Dell PowerConnect 8100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 74 highlights
Data Center - 4.2.0.4 Interoperability Description VLAN request/Notification counters are not incremented for priority tagged packets User Impact Low - FIP sessions are established and are displayed in the show commands. FIP snooping VLAN request or VLAN response counters do not increment when CNA sends priority tagged frames (i.e. VID 0). It is observed that certain CNAs sometimes sends FIP VLAN discovery frames as 802.1Q tagged frames with VID=0 and priority as FCoE priority. FSB snoops FIP packets which are classified to any of FCoE enabled VLANs. In this case, the default VLAN (1) and the configured FCoE VLAN. In general, VLAN request messages are exchanged as untagged so gets associated with VLAN 1. In this case, the BROADCOM CNA sends priority tagged FIP frames (VID=0) which do not match the FSB snooping criteria because they do not get associated to any of the FCoE enabled VLANs hence FCoE VLAN Request/Notification counters are not incremented for priority tagged packets. These control frames are however are forwarded to FCF by FSB in order to establish a successful session. FIP snooping bridge need to consider forwarding priority tagged FIP frames to FCF as well in order to interoperate with CNAs which could send priority tagged packets. The current FSB implementation does this already. Broadcom CNA only supports configuration of VLAN via VLAN Discovery process FIP snooping bridge does not forward the DCBX FIP tlv info from configuration source Low - Most users prefer automatic setup of CNAs The Broadcom CNA does not support manual configuration of VLAN. This means that customers who prefer to set up their FCoE network manually will not be able to do so if using BRCM CNAs. Low - No supported FCF supports this configuration option. While working with QLogic, it is found that CNA sends two TLVs concerning the FIP/FCoE traffic. It sends FIP TLV along with FCoE TLV with respective priorities - in this case same priority for both. Although, it is not a normal use case but can be used to have different treatment for control and data traffic. There can be a use case where host or FCF can choose to create different priorities for control (FIP) and FCoE data traffic. In cases, where FIP and FCoE use different priorities, it is expected that intermediate switches are configured to treat them accordingly. In cases where ports are configured in DCBX auto mode and configuration source carries two TLVs, one for FIP and other for FCoE with different priorities then it is expected that FSB/DCB should forward this information to downstream ports. The PowerConnect FSB implementation ignores the FIP TLV and does not forward this information to the peers. In such cases, Host will not know the special treatment or expected priority for FIP frames. Considering that slow protocol and this being a corner case situation, this can be a readme and documented in release notes. FIP Snooping Over Stack Results in eNode in Ethernet VLAN Low - When trying to accomplish FIP snooping over the stack, the eNode address is put in the wrong VLAN causing the connections to never occur. FCoE is not supported across the stacks so this is a non-issue. End of Release Notes 72 System Firmware Version 5.1.0.1