Dell PowerConnect J-SRX210 Hardware Guide - Page 66
Clearance Requirements for Airflow and Hardware Maintenance of the J-SRX210 Services Gateway
View all Dell PowerConnect J-SRX210 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 66 highlights
PowerConnect J-SRX210 Services Gateway Hardware Guide Clearance Requirements for Airflow and Hardware Maintenance of the J-SRX210 Services Gateway When planning the installation site for the J-SRX210 Services Gateway, you need to allow sufficient clearance around the rack or cabinet where you are planning to install the device. When planning the installation site for the services gateway, consider the following: • For the cooling system to function properly, the airflow around the chassis must be unrestricted. • For service personnel to remove and install hardware components, there must be adequate space at the front and back of the device. Allow at least 24 in. (61 cm) both in front of and behind the device. • If you are mounting the device in a rack with other equipment, or if you are placing it on the desktop near other equipment, ensure that the exhaust from other equipment does not blow into the intake vents of the chassis. Table 22 on page 50 provides information on the clearance requirements for maintaining the optimum airflow and the distances for facilitating easy maintenance of the device. Table 22: Clearance Requirements for the Services Gateway Location Recommended Clearance Requirement for Clearance Front of the chassis Rear of the chassis 2.5 in. (6.35 cm) 2.5 in. (6.35 cm) Space for service personnel to remove and install hardware components NOTE: More space is required for installing and removing Mini-PIMs. Space for service personnel to remove and install hardware components Between front-mounting flange and rack 2.5 in. (6.35 cm) or cabinet edge Space for cable management and organization Between side of the chassis and any non-heat-producing surface such as a wall or cabinet side 2.5 in. (6.35 cm) Space for the cooling system to function properly and to maintain unrestricted airflow around the chassis Between side of the chassis and devices 2.5 in. (6.35 cm) that have fans or blowers Space for the cooling system to function properly and to maintain unrestricted airflow around the chassis Related Topics • J-SRX210 Services Gateway Description on page 3 • General Site Guidelines for Installing the J-SRX210 Services Gateway on page 47 • Site Preparation Checklist for the J-SRX210 Services Gateway on page 45 • J-SRX210 Services Gateway Cabinet Requirements on page 48 50