Dell PowerConnect J-SRX240 Hardware Guide - Page 101
Maintaining the J-SRX240 Services Gateway Hardware Components, Maintaining the J-SRX240
View all Dell PowerConnect J-SRX240 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 101 highlights
CHAPTER 15 Maintaining the J-SRX240 Services Gateway Hardware Components This chapter includes the following topic: • Maintaining the J-SRX240 Services Gateway Hardware Components on page 85 Maintaining the J-SRX240 Services Gateway Hardware Components Table 32 on page 85 describes the common tasks to maintain the hardware components of the services gateway. Table 32: Maintenance Procedures for the Services Gateway Hardware Components Maintenance Procedures Description Routine Maintenance To maintain optimum performance of the services gateway, you should Procedures regularly perform the following preventive maintenance procedures: • Inspect the installation site for moisture, loose wires or cables, and excessive dust. • Make sure that airflow is unobstructed around the device and into the air intake vents. • Check the Status LED on the front panel of the device and on the Mini-Physical Interface Module (Mini-PIM) you are using. Maintaining the Cooling System The services gateway cooling system works to maintain an optimal temperature for the device. If the fan controller fails, the device temperature will exceed the maximum working temperature and the device will fail. Ensure that you maintain the recommended clearances behind the device to enable the cooling system to function optimally. 85