HP Designjet 10000s HP Designjet 10000 Series - User's Guide - Page 290
Initial temperature setting for the print heater PRINT HEATER T, Initial temperature setting for
View all HP Designjet 10000s manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 290 highlights
Parameters: 15 °C to 55 °C, or ** to turn the heater off. NOTE For Celsius/Fahrenheit conversions: F = (9 × C / 5) + 32 C = 5 × (F - 32) / 9 NOTE This value will only be applied if the HEATER PREF option is set to HEAT PANEL. Initial temperature setting for the print heater (PRINT HEATER T) Use this option to set the printer platen heater temperature for the selected media type. Tell me about front panel menus Parameters: 15 °C to 55 °C, or ** to turn the heater off. NOTE For Celsius/Fahrenheit conversions: F = (9 × C / 5) + 32 C = 5 × (F - 32) / 9 NOTE This value will only be applied if the HEATER PREF option is set to HEAT PANEL. Initial temperature setting for the rear heater (REAR HEATER T) Use this option to set the rear heater temperature for the selected media type. Parameters: 15 °C to 55 °C, or ** to turn the heater off. 280 Chapter 14 Tell me about front panel menus ENWW