IBM JS20 Hardware Maintenance Manual - Page 114
Error, FRU/action, Information, only.
![]() |
UPC - 000435230263
View all IBM JS20 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 114 highlights
Error code FRU/action 20EE0011 (unable to execute the vpd method) 1. Go to "Checkout procedure" on page 38. 2. System board and chassis. 20EE0012 (unable to execute the mem-dimm-vpd method) 1. Go to "Checkout procedure" on page 38. 2. System board and chassis. 20EE0015 (failed to read VPD ″boot path″ field value) 1. Verify that the boot list in the management module is correct. 2. Go to "Checkout procedure" on page 38. 3. System board and chassis. 20EE0016 (failed to update VPD with new ″boot path″ field value) 1. Verify that the boot list in the management module is correct. 2. Go to "Checkout procedure" on page 38. 3. System board and chassis. 20EE0020 (environment variable ″boot-device″ exceeds the allowed character limit) 1. Verify that the boot list in the management module is correct. 2. Go to "Checkout procedure" on page 38. 3. System board and chassis. 20EE0021 (environment variable ″boot-device″ contained more than five entries) 1. Verify that the boot list in the management module is correct. 2. Go to "Checkout procedure" on page 38. 3. System board and chassis. 20EE0022 (environment variable 1. Verify that the boot list in the management module is correct. ″boot-device″ contained an entry that exceeded 255 characters in length) 2. Go to "Checkout procedure" on page 38. 3. System board and chassis. 20EE0023 (failure to set operating-system boot-device list from management module boot-device list.) 1. Verify that boot-device list is set correctly in management module. 2. Update firmware for management module and for blade server service processor and firmware. 3. System board and chassis. 20EE0100 (Fcode resident on an I/O v Information only. adapter is not supported on this system; error code affects only boot-time operation, not adapter's functionality under operating system.) 20EE0200 (flashing an image to the permanent side is not allowed.) 1. Boot from the temporary side, then retry flashing. 2. If you are not able to boot from the temporary side, go to "Recovering the system firmware code" on page 54. 20EE0201 (format of the flash image v Flash using a known good image. is not correct.) 20EE0210 (flashing system firmware 1. Flash using a known good image. failed; firmware may be damaged) 2. If the system firmware is damaged, go to "Recovering the system firmware code" on page 54. 20EE0220 (flashing service processor failed; the service processor firmware may be damaged) 1. Flash using a known good image. If the flash fails, the service processor firmware is probably damaged; continue with step 2. 2. System board and chassis. 20FF0001 (VPD problem) 1. Component indicated by location code. 2. System board and chassis. 104 BladeCenter JS20 Type 8842: Hardware Maintenance Manual and Troubleshooting Guide
![](/manual_guide/products/ibm-js20-hardware-maintenance-manual-7a4946f/114.png)