IBM JS20 Hardware Maintenance Manual - Page 19
Preinstallation, checklist
![]() |
UPC - 000435230263
View all IBM JS20 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
Preinstallation checklist Before you can use the BladeCenter unit with the blade server, you must correctly set up and configure the BladeCenter unit, and install and configure the required components in the BladeCenter unit. Read Appendix B, "Safety information," on page 163, and the information in "Installation guidelines" on page 71, and review the documentation that comes with each device and any applicable information in the "Related documentation" on page 3. If you have not already done so, perform the activities on the following checklist: __ 1. Set up the rack in which you will install the BladeCenter unit. __ 2. Install the BladeCenter unit in a rack. For additional information, see the Rack Installation Instructions that come with the BladeCenter unit. __ 3. Install and configure the required BladeCenter unit components: __ a. Make sure that the BladeCenter unit has adequate power to support all the installed devices. The BladeCenter unit must contain either two or four power modules. If necessary, on BladeCenter units that support it, upgrade the power modules in the BladeCenter unit to higher-capacity power modules. For additional information, see the IBM BladeCenter Power Module Upgrade Guidelines Eserver Technical Update. __ b. Install and configure one or two management modules in the BladeCenter unit. __ c. Install and configure one or two Ethernet switch modules in the BladeCenter unit. To support the Serial Over LAN (SOL) feature on any blade server that is installed in the BladeCenter unit: v A SOL-compatible Ethernet switch module must be installed in I/O bay 1 of the BladeCenter unit. v Both the BladeCenter unit and the Ethernet switch module must be configured so that the SOL feature is enabled and set to operate on the same virtual local area network (VLAN). If you plan to install the operating system through the Ethernet network, you also must install and configure a second Ethernet switch module in I/O bay 2 of the BladeCenter unit. Note: If you install other Ethernet switch modules, they do not have to be the same type that you installed in I/O bay 1 of the BladeCenter unit. __ d. Configure the BladeCenter unit for SOL operation as described in the IBM BladeCenter and BladeCenter T Serial Over LAN Setup Eserver Guide. Verify that the firmware code for the BladeCenter unit, management module, and Ethernet switch modules supports the SOL feature. If you are not sure whether these devices come with this feature, see the IBM BladeCenter and BladeCenter T Serial Over LAN Setup Eserver Guide for additional information. The SOL feature is required and must remain enabled for all applicable devices, including the BladeCenter unit, management module, and Ethernet switch modules. __ 4. If the BladeCenter unit was shipped to you before June 2003, make sure that: Chapter 1. Introduction 9
![](/manual_guide/products/ibm-js20-hardware-maintenance-manual-7a4946f/19.png)