IBM JS20 Hardware Maintenance Manual - Page 118
Service, request, numbers
![]() |
UPC - 000435230263
View all IBM JS20 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 118 highlights
Error code FRU/action 25C10003 (companion (in the pair) 1. of the memory DIMM specified by the location code is failing, unsupported, missing, or unmatched) 2. Make sure all DIMMs are supported; replace all unsupported DIMMs and restart server. Make sure all DIMMs are installed in pairs; install DIMMs properly and restart server. 3. Replace the companion of the DIMM specified by the location code and restart server. 4. Replace the DIMM specified by the location code and restart server. 5. Replace the other two DIMMs, if present, one at a time. 6. Replace system board and chassis. 26020008 (PCI device fcode evaluation error) 1. If the location code identifies a slot: a. Reseat adapter and restart system. b. Replace adapter. c. Update system firmware. d. System board and chassis. 2. If the location code identifies system board and chassis, replace system board and chassis. 2B200x31 (processor x is faulty) v System board and chassis. 2B208888 (operating system termination request received) v Information only. 2B2x00EE (exception error reported v System board and chassis. on a processor where x of: 0=unknown interrupt; 1=system reset interrupt (SRI); 2=machine check interrupt; 3=data storage interrupt (DSI); 4=instruction storage interrupt (ISI); 5=external interrupt (EXI); 6=alignment interrupt (ALI); 7=program interrupt (SRI); 8=floating unavailable interrupt (FUI)) Service request numbers Service request numbers (SRNs) are for systems and devices for which this version of the Linux service aid "diagela" can produce an SRN. In the error resolution table that follows, the SRNs are listed in ascending order. Make a note of the SRN and physical location code, if provided, and use the SRN tables to obtain the action plan, as follows: 1. Find the SRN in the table. 2. Perform the actions shown in the FRU/action column. Notes: a. If the SRN number does not appear in the table, contact service and support for assistance. b. An x in an entry represents any number or letter. 3. After replacing a FRU, use the "Checkout procedure" on page 38 to verify the corrective action. 108 BladeCenter JS20 Type 8842: Hardware Maintenance Manual and Troubleshooting Guide
![](/manual_guide/products/ibm-js20-hardware-maintenance-manual-7a4946f/118.png)