IBM JS20 Hardware Maintenance Manual - Page 146
IBM JS20 - BladeCenter - 8842 Manual
UPC - 000435230263
View all IBM JS20 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 146 highlights
Service request number A15-01x A15-03x A15-05x A15-07x A15-11x A15-12x A15-13x SRN source Description FRU/action G Sensor indicates a fan is turning too slowly. 1. Check the BladeCenter management module event log; if an error was recorded by the system or if a checkpoint code is displayed on the console, see Chapter 10, "Symptom-to-FRU index," on page 93. 2. If no entry is found, replace the system board. G Sensor indicates a voltage outside normal range. 1. Check the BladeCenter management module event log; if an error was recorded by the system or if a checkpoint code is displayed on the console, see Chapter 10, "Symptom-to-FRU index," on page 93. 2. If no entry is found, replace the system board. G Sensor indicates an abnormally high internal temperature. 1. Verify that: a. The room ambient temperature is within the system operating environment. b. There is unrestricted air flow around the system. c. All system covers are closed. d. There are no fan failures 2. Check the BladeCenter management module event log; if an error was recorded by the system or if a checkpoint code is displayed on the console, see Chapter 10, "Symptom-to-FRU index," on page 93. 3. If no entry is found, replace the system board. G Sensor indicates a power supply has failed. 1. Check the BladeCenter management module event log; if an error was recorded by the system or if a checkpoint code is displayed on the console, see Chapter 10, "Symptom-to-FRU index," on page 93. 2. If no entry is found, replace the system board. G Sensor detected a redundant fan failure. 1. Check the BladeCenter management module event log; if an error was recorded by the system or if a checkpoint code is displayed on the console, see Chapter 10, "Symptom-to-FRU index," on page 93. 2. If no entry is found, replace the system board. G Sensor detected redundant power supply 1. Check the BladeCenter management module failure. event log; if an error was recorded by the system or if a checkpoint code is displayed on the console, see Chapter 10, "Symptom-to-FRU index," on page 93. 2. If no entry is found, replace the system board. G Sensor detected a redundant FRU that 1. Check the BladeCenter management module has failed. event log; if an error was recorded by the system or if a checkpoint code is displayed on the console, see Chapter 10, "Symptom-to-FRU index," on page 93. 2. If no entry is found, replace the system board. 136 BladeCenter JS20 Type 8842: Hardware Maintenance Manual and Troubleshooting Guide