IBM JS20 Hardware Maintenance Manual - Page 41

Function, Selection, Advanced, Diagnostics, Routines, Diagnostic, System, Verification, Resources,

Page 41 highlights

(such as USB CD-ROM or diskette drive) are assigned to the JS20 blade against which you are running diag -. Follow the prompts to resolve the resource conflict. See"Missing resources" on page 60 for more information. If an 8-digit error code is displayed, go to "Firmware error codes" on page 102, find the error and perform the listed action. If an SRN is displayed, record it and go to "SRN tables" on page 110. c. Then, proceed to the next step. 4. Complete these steps: a. At the command line, type diag and press Enter to move to the Function Selection menu. b. From the Function Selection menu, select Advanced Diagnostics Routines and press Enter. c. From the Diagnostic Mode Selection menu, select System Verification and press Enter. d. When the Diagnostic Selection menu appears, select All Resources, or test only the part you replaced, along with any devices that are attached to the part you replaced, by selecting the diagnostics for the individual part. Press F7 = commit to run the tests. Did the Resource Repair Action menu appear? No Go to Step 5. Yes Go to Step 6. 5. Did the ″Testing complete, no trouble was found″ display appear? No There is still a problem. Contact your service provider. This ends the procedure. Yes Complete the following steps: a. Press F3 or Enter to return to the Advanced Diagnostic selection, then press F3 or press the Esc key and the #3 key for the Function Selection menu. b. Select Task Menu. c. Select Log Repair Action to update the AIX error log. If the repair action was reseating a cable or adapter, select the resource associated with that repair action. If the resource associated with your action is not displayed on the resource list, select ″sysplanar0″ and press F7 = Commit. Note: This action changes the indicator light for the part from the Fault state to the Normal state. Go to Step 8 on page 32. 6. When a test is run on a resource in System Verification mode and that resource has an entry in the AIX error log, then, if the test on the resource was successful, the Resource Repair Action menu appears. After replacing a part, you must select the resource for that part from the Resource Repair Action menu. This updates the AIX error log to indicate that a system-detectable part has been replaced. Note: On systems with an indicator light for the failing part, this changes the indicator light from the Fault state to the Normal state. Follow these steps: a. Select the resource that has been replaced from the Resource Repair Action menu. If the repair action was reseating a cable or adapter, select the Chapter 5. AIX online, standalone and verification procedures 31

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218

(such
as
USB
CD-ROM
or
diskette
drive)
are
assigned
to
the
JS20
blade
against
which
you
are
running
diag
-.
Follow
the
prompts
to
resolve
the
resource
conflict.
See“Missing
resources”
on
page
60
for
more
information.
If
an
8-digit
error
code
is
displayed,
go
to
“Firmware
error
codes”
on
page
102,
find
the
error
and
perform
the
listed
action.
If
an
SRN
is
displayed,
record
it
and
go
to
“SRN
tables”
on
page
110.
c.
Then,
proceed
to
the
next
step.
4.
Complete
these
steps:
a.
At
the
command
line,
type
diag
and
press
Enter
to
move
to
the
Function
Selection
menu.
b.
From
the
Function
Selection
menu,
select
Advanced
Diagnostics
Routines
and
press
Enter.
c.
From
the
Diagnostic
Mode
Selection
menu,
select
System
Verification
and
press
Enter.
d.
When
the
Diagnostic
Selection
menu
appears,
select
All
Resources
,
or
test
only
the
part
you
replaced,
along
with
any
devices
that
are
attached
to
the
part
you
replaced,
by
selecting
the
diagnostics
for
the
individual
part.
Press
F7
=
commit
to
run
the
tests.
Did
the
Resource
Repair
Action
menu
appear?
No
Go
to
Step
5.
Yes
Go
to
Step
6.
5.
Did
the
Testing
complete,
no
trouble
was
found
display
appear?
No
There
is
still
a
problem.
Contact
your
service
provider.
This
ends
the
procedure.
Yes
Complete
the
following
steps:
a.
Press
F3
or
Enter
to
return
to
the
Advanced
Diagnostic
selection,
then
press
F3
or
press
the
Esc
key
and
the
#3
key
for
the
Function
Selection
menu.
b.
Select
Task
Menu
.
c.
Select
Log
Repair
Action
to
update
the
AIX
error
log.
If
the
repair
action
was
reseating
a
cable
or
adapter,
select
the
resource
associated
with
that
repair
action.
If
the
resource
associated
with
your
action
is
not
displayed
on
the
resource
list,
select
sysplanar0
and
press
F7
=
Commit.
Note:
This
action
changes
the
indicator
light
for
the
part
from
the
Fault
state
to
the
Normal
state.
Go
to
Step
8
on
page
32.
6.
When
a
test
is
run
on
a
resource
in
System
Verification
mode
and
that
resource
has
an
entry
in
the
AIX
error
log,
then,
if
the
test
on
the
resource
was
successful,
the
Resource
Repair
Action
menu
appears.
After
replacing
a
part,
you
must
select
the
resource
for
that
part
from
the
Resource
Repair
Action
menu.
This
updates
the
AIX
error
log
to
indicate
that
a
system-detectable
part
has
been
replaced.
Note:
On
systems
with
an
indicator
light
for
the
failing
part,
this
changes
the
indicator
light
from
the
Fault
state
to
the
Normal
state.
Follow
these
steps:
a.
Select
the
resource
that
has
been
replaced
from
the
Resource
Repair
Action
menu.
If
the
repair
action
was
reseating
a
cable
or
adapter,
select
the
Chapter
5.
AIX
online,
standalone
and
verification
procedures
31