Page 117 highlights
Error code FRU/action 25C00000 (no DIMMs detected) 1. Reseat DIMMs and restart server. 2. Go to "Checkout procedure" on page 38. 3. System board and chassis. 25C0xxyy (DIMM failure where: v xx of- 01=DIMM4 missing; 02=DIMM3 unsupported and DIMM4 missing; 04=DIMM3 failed and DIMM4 missing; 10=DIMM3 missing; 12=DIMM3 unsupported; 14=DIMM3 failed; 20=DIMM3 missing and DIMM4 unsupported; 21=DIMM4 unsupported; 22=DIMM3 and DIMM4 unsupported; 24=DIMM3 failed and DIMM4 unsupported; 40=DIMM3 missing and DIMM4 failed; 41=DIMM4 failed; 42=DIMM3 unsupported and DIMM4 failed; 44=DIMM3 and DIMM4 failed; 88=DIMM3 and DIMM4 mismatch v yy of- 01=DIMM2 missing; 02=DIMM1 unsupported and DIMM2 missing; 04=DIMM1 failed and DIMM2 missing; 10=DIMM1 missing; 12=DIMM1 unsupported; 14=DIMM1 failed; 20=DIMM1 missing and DIMM2 unsupported; 21=DIMM2 unsupported; 22=DIMM1 and DIMM2 unsupported; 24=DIMM1 failed and DIMM2 unsupported; 40=DIMM1 missing and DIMM2 failed; 41=DIMM2 failed; 42=DIMM1 unsupported and DIMM2 failed; 44=DIMM1 and DIMM2 failed; 88=DIMM1 and DIMM2 mismatch) 1. Verify that all DIMMs are supported (see "Installing memory modules" on page 77), replacing unsupported DIMMs and restarting. 2. Verify that all DIMMs are correctly seated. 3. Replace one DIMM at a time and restart server each time to isolate failing DIMM. 4. System board and chassis. 25C10001 (memory DIMM error) 1. Make sure all DIMMs are properly seated; reseat DIMMs and restart server. 2. Replace DIMM specified by location code and restart server. 3. Replace the companion DIMM of DIMM in step 2 above and restart server. 4. Replace system board and chassis. 25C10002 (memory DIMM is not supported) 1. Make sure all DIMMs are supported; replace all unsupported DIMMs and restart server. 2. Make sure all DIMMs are installed in pairs; install DIMMs properly and restart server. 3. Replace DIMMs one at a time, restarting the server each time, until the failing DIMM is isolated. 4. Replace system board and chassis. Chapter 10. Symptom-to-FRU index 107
![](/manual_guide/products/ibm-js20-hardware-maintenance-manual-7a4946f/117.png)