Page 147 highlights
Service request number A15-14x A15-17x A15-19x A15-20x A15-21x A15-22x A15-23x SRN source Description G Power fault due to unspecified cause. G Internal redundant power supply failure. G Fan failure. G Non-critical cooling problem, loss of redundant fan. G Over temperature condition. G Fan failure and Over temperature condition. G Non-critical power problem, loss of redundant power supply. FRU/action 1. Check the BladeCenter management module event log; if an error was recorded by the system or if a checkpoint code is displayed on the console, see Chapter 10, "Symptom-to-FRU index," on page 93. 2. If no entry is found, replace the system board. 1. Check the BladeCenter management module event log; if an error was recorded by the system or if a checkpoint code is displayed on the console, see Chapter 10, "Symptom-to-FRU index," on page 93. 2. If no entry is found, replace the system board. 1. Check the BladeCenter management module event log; if an error was recorded by the system or if a checkpoint code is displayed on the console, see Chapter 10, "Symptom-to-FRU index," on page 93. 2. If no entry is found, replace the system board. 1. Check the BladeCenter management module event log; if an error was recorded by the system or if a checkpoint code is displayed on the console, see Chapter 10, "Symptom-to-FRU index," on page 93. 2. If no entry is found, replace the system board. 1. Verify that: a. The room ambient temperature is within the system operating environment. b. There is unrestricted air flow around the system. c. All system covers are closed. d. There are no fan failures 2. Check the BladeCenter management module event log; if an error was recorded by the system or if a checkpoint code is displayed on the console, see Chapter 10, "Symptom-to-FRU index," on page 93. 3. If no entry is found, replace the system board. 1. Check the BladeCenter management module event log; if an error was recorded by the system or if a checkpoint code is displayed on the console, see Chapter 10, "Symptom-to-FRU index," on page 93. 2. If no entry is found, replace the system board. 1. Check the BladeCenter management module event log; if an error was recorded by the system or if a checkpoint code is displayed on the console, see Chapter 10, "Symptom-to-FRU index," on page 93. 2. If no entry is found, replace the system board. Chapter 10. Symptom-to-FRU index 137
![](/manual_guide/products/ibm-js20-hardware-maintenance-manual-7a4946f/147.png)