Page 153 highlights
12 SET MODE I ACC set mode (continued) Selects the transceiver's reference signal condition from IN, OFF and OUT. • IN : Use an external reference signal for the IC7800. • OFF : Not input/output the reference signal. (default) • OUT : Outputs the IC-7800 reference signal to externally connected equipment(s) for their reference. NOTE: If the applied reference signal is off-frequency, or no signal is applied with "IN" selection, the IC-7800 will not work properly. Select "OFF" or "OUT" then reboot the IC-7800 in such case. Adjusts the internal reference signal frequency within 0 to 100% range in 1% steps during frequency calibration. (default: 50%) 12-10
12-10
12
SET MODE
Adjusts the internal reference signal frequency within
0 to 100% range in 1% steps during frequency cali-
bration. (default: 50%)
Selects the transceiver’s reference signal condition
from IN, OFF and OUT.
• IN
: Use an external reference signal for the IC-
7800.
• OFF
: Not input/output the reference signal.
(default)
• OUT
: Outputs the IC-7800 reference signal to ex-
ternally connected equipment(s) for their ref-
erence.
NOTE:
If the applied reference signal is off-fre-
quency, or no signal is applied with “IN” selection,
the IC-7800 will not work properly. Select “OFF” or
“OUT” then reboot the IC-7800 in such case.
■