Icom IC-7800 Instruction Manual - Page 59

Keyer set mode - specifications

Page 59 highlights

4 RECEIVE AND TRANSMIT D Keyer set mode [F-1•Y] [F-2•Z][F-4•DEF] [EXIT/SET] Main dial • Keyer set mode screen This set mode is used to set the memory keyer repeat time, dash weight, paddle specifications, keyer type, etc. • Setting contents q During CW mode operation, push [F-3•KEYER] to select memory keyer screen. w Push [EXIT•SET] to select memory keyer menu, then push [F-4•CW KEY] to select keyer set mode. e Push [F-1•Y] or [F-2•Z] to select the desired set item. r Set the desired condition using the main dial. • Push [F-4•DEF] for 1 sec. to select the default condition or value. t Push [EXIT/SET] twice to normal screen. When sending CW using the repeat timer, this item sets the time between transmission. • 1 to 60 sec. in 1 sec. steps can be selected. (default: 2 sec.) This item sets the dot/dash ratio. Keying weight example: Morse code "K" Weight setting: 1:1:3 (default) DOT (fixed*) DASH DASH Weight setting: Adjusted Adjustable range SPACE (fixed*) *SPACE and DOT length can be adjusted with [KEY SPEED] only. • 1:1:2.8 to 1:1:4.5 (in 0.1 steps) can be selected. (default: 1:1:3.0) This item sets the rise time of the transmitted CW envelope. • About rise time Tx Key action Rx • 2, 4, 6 or 8 msec. can be selected. (default: 4 msec.) Tx output power Set Tx power level 0 Rise time Time 4-11 to be continued...

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206

4-11
D
Keyer set mode
This set mode is used to set the memory keyer repeat
time, dash weight, paddle specifications, keyer type,
etc.
Setting contents
q
During CW mode operation, push [F-3•KEYER] to
select memory keyer screen.
w
Push [EXIT•SET] to select memory keyer menu,
then push [F-4•CW KEY] to select keyer set mode.
e
Push [F-1•
Y
] or [F-2•
Z
] to select the desired set
item.
r
Set the desired condition using the main dial.
• Push [F-4•DEF] for 1 sec. to select the default condition
or value.
Keyer set mode screen
t
Push [EXIT/SET] twice to normal screen.
[F-1
Y
]
Main dial
[EXIT/SET]
[F-2
Z
][F-4
DEF]
4
RECEIVE AND TRANSMIT
When sending CW using the repeat timer, this item
sets the time between transmission.
• 1 to 60 sec. in 1 sec. steps can be selected.
(default: 2 sec.)
This item sets the dot/dash ratio.
Keying weight example:
Morse code “K”
• 1:1:2.8 to 1:1:4.5 (in 0.1 steps) can be selected.
(default: 1:1:3.0)
DASH
Weight setting:
1:1:3 (default)
Weight setting:
Adjusted
DASH
DOT (fixed*)
Adjustable range
SPACE (fixed*)
*SPACE and DOT length can be
adjusted with [KEY SPEED] only.
This item sets the rise time of the transmitted CW en-
velope.
• 2, 4, 6 or 8 msec. can be selected. (default: 4 msec.)
Key action
Tx output power
About rise time
Rise time
Tx
Rx
Set Tx power level
Time
0
to be continued…