Icom IC-7800 Instruction Manual - Page 184

Control Command

Page 184 highlights

CONTROL COMMAND 14 D Command table (continued) Command Sub command Description 1A 050035 Send/read the band selection for operating frequency band signal output to ACC-A. (0=MAIN, 1=SUB, 2=TX) 050036 Send/read the band selection for operating frequency band signal output to ACC-A. (0=MAIN, 1=SUB, 2=TX) 050037 Send/read relay type selection (0=Lead, 1=MOS-FET) 050038 Send/read main band's external meter output selection (0=Auto, 1=S (main), 2=Po, 3=SWR, 4=ALC, 5=COMP, 6=VD, 7=ID) 050039 Send/read sub band's external meter output selection (0=Auto, 1=S (sub), 2=Po, 3=SWR, 4=ALC, 5=COMP, 6=VD, 7=ID) 050040 Send/read main band's external meter output level (0=0% to 255=100%) 050041 Send/read sub band's external meter output level (0=0% to 255=100%) 050042 Send/read reference signal in/out setting (0=OFF, 1=IN, 2=OUT) 050043 Send/read reference signal fre- quency setting (0=0% to 255=100%) 050044 Send/read LCD unit backlight brightness (0=0% to 255=100%) 050045 Send/read switch indicator bright- ness (0=0% to 255=100%) 050046 Send/read screen image type (0=A, 1=B, 2=C) 050047 Send/read frequency readout font (0=Italic (1), 1=Italic (2), 2=Italic (3), 3=Italic (4), 4=Round (1), 5=Round (2), 6=Round (3), 7=Shadow (1), 8=Shadow (2), 9=Shadow (3), 10=Qubic (1), 11=Qubic (2), 12=Qubic (3), 13=Qubic (4), 14=IC-780 (1), 15=IC-780 (2), 16=IC-780 (3), 17=IC-780 (4)) 050048 Send/read font for other than fre- quency readout (0=Normal, 1=Slim) 050049 Send/read meter type (0=Standard, 1=Edgewise, 2=Bar) 050050 Send/read meter type during wide screen or mini scope indication (0=Edgewise, 1=Bar) 050051 Send/read peak hold set (0=OFF, 1=ON) 050052 Send/read memory name indica- tion setting (0=OFF, 1=ON) 050053 Send/read audio peak filter width pop-up indication setting (0=OFF, 1=ON) 050054 Send/read manual notch width pop-up indication setting (0=OFF, 1=ON) 050055 Send/read output signal setting for external display (0=OFF, 1=ON) 050056 Send/read synchronous pulse level setting (0=L, 1=H) Command 1A 14-5 Sub command Description 050057 050058 050059 050060 050061 050062 050063 050064 050065 050066 050067 050068 050069 050070 050071 050072 050073 050074 050075 050076 050077 050078 050079 050080 050081 050082 050083 050084 050085 050086 Send/read opening message indication (0=OFF, 1=ON) Send/read opening message contents (see p. 14-9 for details) Send/read date (20000101=1st Jan. 2001 to 20991231=31st Dec. 2099) Send/read time (0000=00:00 to 2359=23:59) Send/read clock 2 function (0=OFF, 1=ON) Send/read offset time for clock 2 (240001=-24:00 to 240000=+24:00) Send/read clock 2 name (up to 3character; see p. 14-9) Send/read calibration marker (0=OFF, 1=ON) Send/read confirmation beep (0=OFF, 1=ON) Send/read band edge beep (0=OFF, 1=ON) Send/read main band's beep audio frequency (50=500 Hz to 200=2000 Hz) Send/read sub band's beep audio frequency (50=500 Hz to 200=2000 Hz) Send/read quick dualwatch function (0=OFF, 1=ON) Send/read quick split set (0=OFF, 1=ON) Send/read FM split offset -9.999 to +9.999 MHz for HF (see p. 14-10 for details) Send/read FM split offset -9.999 to +9.999 MHz for 50 MHz (see p. 14-10 for details) Send/read split lock set (0=OFF, 1=ON) Send/read tuner auto start set (0=OFF, 1=ON) Send/read PTT tune set (0=OFF, 1=ON) Send/read transverter set (0=OFF, 1=ON) Send/read transverter offset (see p. 14-10 for details) Send/read RTTY mark frequency (0=1275 Hz, 1=1615 Hz, 2=2125 Hz) Send/read RTTY shift width (0=170 Hz, 1=200 Hz, 2=425 Hz) Send/read RTTY keying polarity (0=Normal, 1=Reverse) Send/read PSK tone frequency (0=1000 Hz, 1=1500 Hz, 2=2000 Hz) Send/read speech language (0=English, 1=Japanese) Send/read speech speed (0=Slow, 1=Fast) Send/read S-level speech (0=OFF, 1=ON) Send/read speech with a mode switch operation (0=OFF, 1=ON) Send/read memo pad numbers (0=5 ch, 1=10 ch)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206

14-5
D
Command table (continued)
14
CONTROL COMMAND
Command
Sub command
Description
1A
050035
Send/read the band selection for
operating frequency band signal
output to ACC-A. (0=MAIN,
1=SUB, 2=TX)
050036
Send/read the band selection for
operating frequency band signal
output to ACC-A. (0=MAIN,
1=SUB, 2=TX)
050037
Send/read relay type selection
(0=Lead, 1=MOS-FET)
050038
Send/read main band’s external
meter output selection (0=Auto,
1=S (main), 2=Po, 3=SWR,
4=ALC, 5=COMP, 6=V
D
, 7=I
D
)
050039
Send/read sub band’s external
meter output selection (0=Auto,
1=S (sub), 2=Po, 3=SWR,
4=ALC, 5=COMP, 6=V
D
, 7=I
D
)
050040
Send/read main band’s external
meter output level
(0=0% to 255=100%)
050041
Send/read sub band’s external
meter output level
(0=0% to 255=100%)
050042
Send/read reference signal in/out
setting (0=OFF, 1=IN, 2=OUT)
050043
Send/read reference signal fre-
quency setting
(0=0% to 255=100%)
050044
Send/read LCD unit backlight
brightness (0=0% to 255=100%)
050045
Send/read switch indicator bright-
ness (0=0% to 255=100%)
050046
Send/read screen image type
(0=A, 1=B, 2=C)
050047
Send/read frequency readout font
(
0=Italic (1), 1=Italic (2), 2=Italic (3),
3=Italic (4), 4=Round (1),
5=Round (2), 6=Round (3),
7=Shadow (1), 8=Shadow (2),
9=Shadow (3), 10=Qubic (1),
11=Qubic (2), 12=Qubic (3),
13=Qubic (4), 14=IC-780 (1),
15=IC-780 (2), 16=IC-780 (3),
17=IC-780 (4))
050048
Send/read font for other than fre-
quency readout
(0=Normal, 1=Slim)
050049
Send/read meter type
(0=Standard, 1=Edgewise, 2=Bar)
050050
Send/read meter type during wide
screen or mini scope indication
(0=Edgewise, 1=Bar)
050051
Send/read peak hold set
(0=OFF, 1=ON)
050052
Send/read memory name indica-
tion setting (0=OFF, 1=ON)
050053
Send/read audio peak filter width
pop-up indication setting
(0=OFF, 1=ON)
050054
Send/read manual notch width
pop-up indication setting
(0=OFF, 1=ON)
050055
Send/read output signal setting for
external display (0=OFF, 1=ON)
050056
Send/read synchronous pulse
level setting (0=L, 1=H)
Command
Sub command
Description
1A
050057
Send/read opening message indi-
cation (0=OFF, 1=ON)
050058
Send/read opening message con-
tents (see p. 14-9 for details)
050059
Send/read date (20000101=1st
Jan. 2001 to 20991231=31st Dec.
2099)
050060
Send/read time (0000=00:00 to
2359=23:59)
050061
Send/read clock 2 function
(0=OFF, 1=ON)
050062
Send/read offset time for clock 2
(240001=–24:00 to 240000=+24:00)
050063
Send/read clock 2 name (up to 3-
character; see p. 14-9)
050064
Send/read calibration marker
(0=OFF, 1=ON)
050065
Send/read confirmation beep
(0=OFF, 1=ON)
050066
Send/read band edge beep
(0=OFF, 1=ON)
050067
Send/read main band’s beep
audio frequency
(50=500 Hz to 200=2000 Hz)
050068
Send/read sub band’s beep audio
frequency
(50=500 Hz to 200=2000 Hz)
050069
Send/read quick dualwatch func-
tion (0=OFF, 1=ON)
050070
Send/read quick split set (0=OFF,
1=ON)
050071
Send/read FM split offset –9.999
to +9.999 MHz for HF
(see p. 14-10 for details)
050072
Send/read FM split offset –9.999
to +9.999 MHz for 50 MHz
(see p. 14-10 for details)
050073
Send/read split lock set (0=OFF,
1=ON)
050074
Send/read tuner auto start set
(0=OFF, 1=ON)
050075
Send/read PTT tune set (0=OFF,
1=ON)
050076
Send/read transverter set
(0=OFF, 1=ON)
050077
Send/read transverter offset (see
p. 14-10 for details)
050078
Send/read RTTY mark frequency
(0=1275 Hz, 1=1615 Hz,
2=2125 Hz)
050079
Send/read RTTY shift width
(0=170 Hz, 1=200 Hz, 2=425 Hz)
050080
Send/read RTTY keying polarity
(0=Normal, 1=Reverse)
050081
Send/read PSK tone frequency
(0=1000 Hz, 1=1500 Hz,
2=2000 Hz)
050082
Send/read speech language
(0=English, 1=Japanese)
050083
Send/read speech speed (0=Slow,
1=Fast)
050084
Send/read S-level speech
(0=OFF, 1=ON)
050085
Send/read speech with a mode
switch operation (0=OFF, 1=ON)
050086
Send/read memo pad numbers
(0=5 ch, 1=10 ch)