Netgear GS724AT GS724AT Reference Manual - Page 172

Monitoring the Switch, Setting Monitoring Options, Logs

Page 172 highlights

Chapter 7 Monitoring the Switch Setting Monitoring Options The navigation pane at the top of the web browser interface contains a Monitoring tab that enables you to manage your GS700AT Series Smart Switch with features under the following main menu options: • "Logs" • "RMON" • "Port Mirroring" The description that follows in this chapter describes configuring and managing monitoring settings in the GS700AT Series Smart Switch. Logs Event messages have a unique format, as per the SYSLOG RFC recommended message format for all error reporting, for example, Syslog+ local device reporting. Messages are assigned a severity code, and include a message mnemonic, which identifies the source application generating the message. Messages are filtered based on their urgency or relevancy. The following table contains the Log Severity Levels: Table 7-1. Severity Levels Severity Severity Level Severity Level Description Emergency 0 Alert 1 The system is not functioning. The system needs immediate attention. Critical 2 Error 3 Warning 4 The system is in a critical state. A system error has occurred. A system warning is logged. Notice 5 The system is functioning properly, but a system notice is logged. 7-1 v1.0, March 2008

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209

7-1
v1.0, March 2008
Chapter 7
Monitoring the Switch
Setting Monitoring Options
The navigation pane at the top of the web browser interface contains a Monitoring tab that enables
you to manage your GS700AT Series Smart Switch with features under the following main menu
options:
“Logs”
“RMON”
“Port Mirroring”
The description that follows in this chapter describes configuring and managing monitoring
settings in the GS700AT Series Smart Switch.
Logs
Event messages have a unique format, as per the SYSLOG RFC recommended message format for
all error reporting, for example, Syslog+ local device reporting. Messages are assigned a severity
code, and include a message mnemonic, which identifies the source application generating the
message. Messages are filtered based on their urgency or relevancy. The following table contains
the Log Severity Levels:
Table 7-1.
Severity Levels
Severity
Severity Level
Severity Level Description
Emergency
0
The system is not functioning.
Alert
1
The system needs immediate attention.
Critical
2
The system is in a critical state.
Error
3
A system error has occurred.
Warning
4
A system warning is logged.
Notice
5
The system is functioning properly, but a system notice is logged.