GS700AT Series Smart Switch Software Administration Manual • VLAN Type - Select the VLAN type for which the network policy is defined. The possible field values are: - Tagged - The network policy is defined for tagged VLANs. - Untagged - The network policy is defined for untagged VLANs. • User Priority - Select the priority assigned to the network application. The field range is 0 - 7. • DSCP Value - Select the DSCP value assigned to the network policy. The possible field value is 0 - 63. 2. Select the Network Policy entry to configure. 3. Select the Network Policy Number from the list in the provided field in the first row. 4. Enter the VLAN ID in the provided field in the first row. 5. Select the VLAN Type from the list in the provided field in the first row. 6. Select the User Priority from the list in the provided field in the first row. 7. Select the DSCP Value from the list in the provided field in the first row. 8. Click Apply to update the device. To add a new network policy entry: 1. Click System > LLDP > Advanced > LLDP-MED Network Policy. The LLDP-MED Network Policy screen displays. 2. Select the Network Policy Number from the list in the provided field in the first row. 3. Enter the VLAN ID in the provided field in the first row. 4. Select the VLAN Type from the list in the provided field in the first row. 5. Select the User Priority from the list in the provided field in the first row. 6. Select the DSCP Value from the list in the provided field in the first row. 7. Click Add to update the device. To remove a network policy entry: 1. Click System > LLDP > Advanced > LLDP-MED Network Policy. The LLDP-MED Network Policy screen displays. 2. Select the Network Policy entry. 3. Click Delete to remove the entry. Managing System Settings v1.0, March 2008 3-35

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209

GS700AT Series Smart Switch Software Administration Manual
Managing System Settings
3-35
v1.0, March 2008
VLAN Type
– Select the VLAN type for which the network policy is defined. The
possible field values are:
Tagged – The network policy is defined for tagged VLANs.
Untagged – The network policy is defined for untagged VLANs.
User Priority
– Select the priority assigned to the network application. The field range is
0 - 7.
DSCP Value
– Select the DSCP value assigned to the network policy. The possible field
value is 0 - 63.
2.
Select the Network Policy entry to configure.
3.
Select the
Network Policy Number
from the list in the provided field in the first row.
4.
Enter the
VLAN ID
in the provided field in the first row.
5.
Select the
VLAN Type
from the list in the provided field in the first row.
6.
Select the
User Priority
from the list in the provided field in the first row.
7.
Select the
DSCP Value
from the list in the provided field in the first row.
8.
Click
Apply
to update the device.
To add a new network policy entry:
1.
Click
System > LLDP > Advanced
>
LLDP-MED Network Policy
. The LLDP-MED
Network Policy screen displays.
2.
Select the
Network Policy Number
from the list in the provided field in the first row.
3.
Enter the
VLAN ID
in the provided field in the first row.
4.
Select the
VLAN Type
from the list in the provided field in the first row.
5.
Select the
User Priority
from the list in the provided field in the first row.
6.
Select the
DSCP Value
from the list in the provided field in the first row.
7.
Click
Add
to update the device.
To remove a network policy entry:
1.
Click
System > LLDP > Advanced
>
LLDP-MED Network Policy
. The LLDP-MED
Network Policy screen displays.
2.
Select the Network Policy entry.
3.
Click
Delete
to remove the entry.