Dell PowerVault NX3500 Hardware Owner's Manual - Page 27
Check PSU and, Mismatch. PSU1
View all Dell PowerVault NX3500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 27 highlights
Table 1-3. LCD Status Messages (continued) Code E161C E1620 E1624 E1626 E1629 Text Causes Corrective Actions Power Supply # (### W) lost AC power. Check PSU cables. Specified power supply is attached to the system, but it has lost its AC input. Check the AC power source for the specified power supply. If the problem persists, see "Troubleshooting Power Supply" on page 96. Power Supply # (### W) AC power error. Check PSU cables. Specified power supply's AC input is outside of the allowable range. Check the AC power source for the specified power supply. If the problem persists, see "Troubleshooting Power Supply" on page 96. Lost power supply redundancy. Check PSU cables. The power supply subsystem is no longer redundant. If the remaining power supply fails, the system will shut down. See "Troubleshooting Power Supply" on page 96. Power Supply The power supplies in Mismatch. PSU1 the system are not the = ### W, PSU2 same wattage. = ### W. Ensure that power supplies with matching wattage are installed. See the Technical Specifications outlined in your system's Getting Started Guide. Power required > PSU wattage. Check PSU and config. The system configuration requires more power than the power supplies can provide, even with throttling. Turn off power to the system, reduce the hardware configuration or install higher-wattage power supplies, and then restart the system. About Your Solution 27