Dell PowerVault NX3500 Hardware Owner's Manual - Page 43
geometry, in rank, count, in size, and geometry, and rank count, Check the Time and Date
View all Dell PowerVault NX3500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 43 highlights
Table 1-4. System Messages (continued) Message The following DIMMs should match in geometry: x,x,... The following DIMMs should match in rank count: x,x,... Causes Corrective Actions Invalid memory configuration. The specified memory modules do not match in size, number of ranks, or number of data lanes. Ensure that the memory modules are installed in a valid configuration. See "General Memory Module Installation Guidelines" on page 67. The following DIMMs should match in size: x,x,... The following DIMMs should match in size and geometry: x,x,... The following DIMMs should match in size and rank count: x,x,... Thermal sensor not detected on x. A memory module without a Replace the memory thermal sensor is installed in module. See "System the specified memory slot. Memory" on page 66. Time-of-day clock stopped. Faulty battery or faulty chip. See "Troubleshooting the System Battery" on page 95. Time-of-day not Incorrect Time or Date set - please run settings; faulty system SETUP program. battery. Check the Time and Date settings. If the problem persists, replace the system battery. See "System Battery" on page 79. Timer chip Faulty system board. counter 2 failed. See "Getting Help" on page 113. About Your Solution 43