Dell PowerVault NX3500 Hardware Owner's Manual - Page 42
See Getting Help on, Troubleshooting a Hard
View all Dell PowerVault NX3500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 42 highlights
Table 1-4. System Messages (continued) Message Causes Sector not found. Faulty hard drive. Seek error. Seek operation failed. Shutdown failure. General system error. The amount of Memory has been added or system memory has removed or a memory changed. module may be faulty. Corrective Actions Replace the hard drive. Ensure that the SAS backplane cables are properly connected. See "Troubleshooting a Hard Drive" on page 100 for the appropriate drive(s) installed in your system. See "Getting Help" on page 113. If memory has been added or removed, this message is informative and can be ignored. If memory has not been added or removed, check the SEL to determine if single-bit or multi-bit errors were detected and replace the faulty memory module. See "Troubleshooting System Memory" on page 97. 42 About Your Solution