HP StorageWorks 2/16V Brocade Fabric Watch Administrator's Guide - Supporting - Page 77

TABLE 17, displayed for that port.

Page 77 highlights

Types of Fabric Watch reports 4 208 G HEALTHY 000:00 209 G HEALTHY 000:00 210 G HEALTHY 000:00 211 G HEALTHY 000:00 212 G HEALTHY 000:00 213 G HEALTHY 000:00 214 G HEALTHY 000:00 215 G HEALTHY 000:00 216 VE HEALTHY 061:19 217 VE HEALTHY 061:19 218 VE HEALTHY 061:19 219 VE HEALTHY 003:37 220 VE HEALTHY 002:48 221 VE HEALTHY 061:19 222 VE HEALTHY 061:19 223 VE HEALTHY 061:19 NOTE Output of the Port Detail Report depends on the ports that belong to the current Admin Domain context. If a port does not belong to the current Admin Domain, nothing other than port number is displayed for that port. Example: "000 Not a member of current Admin Domain Table 17 lists and describes each item in the port detail report. TABLE 17 Port detail report columns Report item Description LFA Link Loss: the number of link loss occurrences out of range for time period LSY Sync Loss: the number of sync loss occurrences out of range for time period LSI Signal Loss: the number of signal loss occurrences out of range for time period PER Protocol Error: the number of protocol errors out of range for time period INW Invalid word. The number of invalid words out of range for time period CRC Invalid CRC: the number of CRC errors out of range for time period PSC Port hardware state changed too often due to fabric reconfiguration BLP Buffer limited port: the switch status changes when a port is in a buffer limited mode based on the switch status policy. STM SFP temperature is out of specifications SRX SFP receive power is out of specifications STX SFP transmit power is out of specifications SCU SFP current is out of specifications SVO SFP voltage is out of specifications Fabric Watch Administrator's Guide 61 53-0000438-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102

Fabric Watch Administrator’s Guide
61
53-0000438-01
Types of Fabric Watch reports
4
208
G
HEALTHY
000:00
-
-
-
-
-
-
-
-
-
-
-
-
-
209
G
HEALTHY
000:00
-
-
-
-
-
-
-
-
-
-
-
-
-
210
G
HEALTHY
000:00
-
-
-
-
-
-
-
-
-
-
-
-
-
211
G
HEALTHY
000:00
-
-
-
-
-
-
-
-
-
-
-
-
-
212
G
HEALTHY
000:00
-
-
-
-
-
-
-
-
-
-
-
-
-
213
G
HEALTHY
000:00
-
-
-
-
-
-
-
-
-
-
-
-
-
214
G
HEALTHY
000:00
-
-
-
-
-
-
-
-
-
-
-
-
-
215
G
HEALTHY
000:00
-
-
-
-
-
-
-
-
-
-
-
-
-
216
VE
HEALTHY
061:19
-
-
-
-
-
-
-
-
-
-
-
-
-
217
VE
HEALTHY
061:19
-
-
-
-
-
-
-
-
-
-
-
-
-
218
VE
HEALTHY
061:19
-
-
-
-
-
-
-
-
-
-
-
-
-
219
VE
HEALTHY
003:37
-
-
-
-
-
-
-
-
-
-
-
-
-
220
VE
HEALTHY
002:48
-
-
-
-
-
-
-
-
-
-
-
-
-
221
VE
HEALTHY
061:19
-
-
-
-
-
-
-
-
-
-
-
-
-
222
VE
HEALTHY
061:19
-
-
-
-
-
-
-
-
-
-
-
-
-
223
VE
HEALTHY
061:19
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
Output of the Port Detail Report depends on the ports that belong to the current Admin Domain
context. If a port does not belong to the current Admin Domain, nothing other than port number is
displayed for that port.
Example:
“000
----------------Not a member of current Admin Domain-------------------”
Table 17
lists and describes each item in the port detail report.
TABLE 17
Port detail report columns
Report item
Description
LFA
Link Loss: the number of link loss occurrences out of range for time period
LSY
Sync Loss: the number of sync loss occurrences out of range for time period
LSI
Signal Loss: the number of signal loss occurrences out of range for time period
PER
Protocol Error: the number of protocol errors out of range for time period
INW
Invalid word. The number of invalid words out of range for time period
CRC
Invalid CRC: the number of CRC errors out of range for time period
PSC
Port hardware state changed too often due to fabric reconfiguration
BLP
Buffer limited port: the switch status changes when a port is in a buffer limited mode based
on the switch status policy.
STM
SFP temperature is out of specifications
SRX
SFP receive power is out of specifications
STX
SFP transmit power is out of specifications
SCU
SFP current is out of specifications
SVO
SFP voltage is out of specifications