HP StorageWorks 2/16V Brocade Fabric Watch Administrator's Guide - Supporting - Page 85
TABLE 19, Environment class threshold defaults Continued
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 85 highlights
Environment class TABLE 19 Environment class threshold defaults (Continued) Area Description Default threshold settings Default alarm settings Threshold state Power Supply Temperature Monitors power supply condition Monitors switch temperature in Celsius Unit: 1/0 (OK/FAULTY) Time Base: none The default threshold settings for all platforms are: Low: 1 High: 0 Buffer:0 Changed: 0 Below: 3 Above: 3 In-Between: 0 Unit: degrees C Time Base: none Brocade 200E Low: 0 High: 60 Buffer: 10 Brocade 3850 and 3250 Low: 0 High: 64 Buffer: 10 Brocade 3900 Low: 0 High: 67 Buffer: 10 Brocade 4100 Low:0 High: 60 Buffer: 10 Brocade 4900 Low: 0 High: 47 Buffer: 10 Brocade 5000 Low:0 High: 60 Buffer: 10 Brocade 7500 Low: 0 High: 63 Buffer: 10 Brocade 7600 Low: 0 High: 63 Buffer: 10 Brocade 24000 Low: 0 High: 75 Buffer: 10 Brocade 48000 Low: 0 High: 60 Buffer: 10 Changed: 0 Below: 3 Above: 3 In-Between: 3 Informative Out_of_range In_range Informative Informative Out_of_range Out_of_range In_range Fabric Watch Administrator's Guide 69 53-0000438-01