HP StorageWorks 2/16V Brocade Fabric Watch Administrator's Guide - Supporting - Page 94
TABLE 29, SFP class threshold defaults
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 94 highlights
SFP class TABLE 29 SFP class threshold defaults Area Description Default threshold settings Current Receive Power Supply Voltage Temperature Transmit Power Monitors SFP current Monitors receive power in µWatts Monitors SFP electrical force in volt(s) Monitors SFP Temperature Monitors transmit power in µWatts Unit: mA Time Base: none Low: 0 High: 50 Buffer: 1 Unit: µWatts Time Base: none Low: 0 High: 5000 Buffer: 25 Unit: mV Time Base: none Low: 3150 High: 3600 Buffer: 10 Unit: Degrees C Time Base: none Low: -10 High: 85 Buffer: 3 Unit: µWatts Time Base: none Low: 0 High: 5000 Buffer: 25 Default alarm settings Threshold state Changed: 0 Below: 1 Above: 1 In-Between: 0 Informative Out_of_range Out_of_range Informative Changed: 0 Below: 1 Above: 1 In-Between: 0 Informative Out_of_range Out_of_range Informative Changed: 0 Below: 1 Above: 1 In-Between: 0 Informative Out_of_range Out_of_range Informative Changed: 0 Below: 1 Above: 1 In-Between: 1 Informative Out_of_range Out_of_range Normal Changed: 0 Below: 1 Above: 1 In-Between: 0 Informative Out_of_range Out_of_range Normal 78 Fabric Watch Administrator's Guide 53-0000438-01