HP StorageWorks 2/16V Brocade Fabric Watch Administrator's Guide - Supporting - Page 84
Environment class
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 84 highlights
Environment class Environment class Table 19 provides default settings for areas in the Environment class. These defaults are hardware-dependent. Check the appropriate hardware reference manual for differences in environmental requirements. NOTE For the Brocade 200E, there is no fan default threshold because the fans are not monitored by Fabric Watch. You can use the fanShow command to view the Brocade 200E fan status (OK or NOT OK). However, you cannot use the fwConfigure command to manipulate the threshold or alarm actions against any fans. TABLE 19 Area Fan Environment class threshold defaults Description Default threshold settings Default alarm settings Threshold state Monitors switch fan speed in RPMs Unit: RPM Time Base: none Brocade 3850 and 3250 Low: 4500 High: 11000 Buffer: 3 Brocade 3900 Low: 2600 High: 10000 Buffer: 3 Brocade 4100 Low: 3000 High: 12000 Buffer: 3 Brocade 4900 Low: 4100 High: 8500 Buffer: 3 Brocade 5000 Low: 3000 High: 12000 Buffer: 3 Brocade 7500 Low: 5000 High: 16000 Buffer: 3 Brocade 7600 Low: 5000 High: 16000 Buffer: 3 Brocade 24000 Low: 1600 High: 3400 Buffer: 3 Brocade 48000 Low: 1600 High: 3400 Buffer: 3 Changed: 0 Above: 3 Below: 3 In-Between: 1 Informative Out_of_range Out_of_range In_range 68 Fabric Watch Administrator's Guide 53-0000438-01