HP StorageWorks 2/16V Brocade Fabric Watch Administrator's Guide - Supporting - Page 87

Performance Monitor class

Page 87 highlights

Performance Monitor class Performance Monitor class Table 21 provides default settings for areas in the AL_PA Performance Monitor class. TABLE 21 AL_PA Performance Monitor class threshold defaults Area Description Default threshold settings Default alarm Threshold state settings AL_PA Invalid CRCs Monitors the number of arbitrated loop physical address CRC errors Unit: Error(s) Time Base: minute Low: 0 High: 60 Buffer: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Informative Informative Out_of_range In_range NOTE End-to-end and AL_PA CRC counters are not supported on the Brocade 200E switch, 4100 switch, and 48000 director. Table 22 provides default settings for areas in the Customer-Defined Performance Monitor class. TABLE 22 Customer-defined Performance Monitor class threshold defaults Area Description Default threshold settings Default alarm Threshold state settings Customer-Defined Filter Monitors the number of frames that are filtered out by the port Unit: Frame(s) Time Base: none Low: 0 High: 0 Buffer: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Informative Informative Informative Informative Table 23 provides default settings for areas in the End-to-End Performance Monitor class. TABLE 23 End-to-end Performance Monitor class threshold defaults Area Description Default threshold settings Default alarm Threshold state settings End-to-End Invalid CRC Count Monitors the number of CRC errors between a SID_DID pair in a port Unit: Errors Time Base: minute Low: 1 High: 10 Buffer: 0 End-to-End Receive Performance Monitors the receiving traffic between a SID_DID pair in a port Unit: KB/sec Time Base: none Low: 0 High: 0 Buffer: 0 End-to-End Transmit Performance Monitors the transmit traffic between a SID_DID pair in a port Unit: KB/sec Time Base: none Low: 0 High: 0 Buffer: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Informative Informative Out_of_range In_range Informative Informative Informative Informative Informative Informative Informative Informative Fabric Watch Administrator's Guide 71 53-0000438-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102

Fabric Watch Administrator’s Guide
71
53-0000438-01
Performance Monitor class
Performance Monitor class
Table 21
provides default settings for areas in the AL_PA Performance Monitor class.
NOTE
End-to-end and AL_PA CRC counters are not supported on the Brocade 200E switch, 4100 switch,
and 48000 director.
Table 22
provides default settings for areas in the Customer-Defined Performance Monitor class.
Table 23
provides default settings for areas in the End-to-End Performance Monitor class.
TABLE 21
AL_PA Performance Monitor class threshold defaults
Area
Description
Default threshold settings
Default alarm
settings
Threshold state
AL_PA Invalid CRCs
Monitors the number of
arbitrated loop physical
address CRC errors
Unit: Error(s)
Time Base: minute
Low: 0
High: 60
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
TABLE 22
Customer-defined Performance Monitor class threshold defaults
Area
Description
Default threshold settings
Default alarm
settings
Threshold state
Customer-Defined Filter
Monitors the
number of frames
that are filtered
out by the port
Unit: Frame(s)
Time Base: none
Low: 0
High: 0
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
TABLE 23
End-to-end Performance Monitor class threshold defaults
Area
Description
Default threshold settings
Default alarm
settings
Threshold state
End-to-End Invalid CRC
Count
Monitors the number
of CRC errors
between a SID_DID
pair in a port
Unit: Errors
Time Base: minute
Low: 1
High: 10
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
End-to-End Receive
Performance
Monitors the
receiving traffic
between a SID_DID
pair in a port
Unit: KB/sec
Time Base: none
Low: 0
High: 0
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
End-to-End Transmit
Performance
Monitors the
transmit traffic
between a SID_DID
pair in a port
Unit: KB/sec
Time Base: none
Low: 0
High: 0
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative