Maytag MHWZ600TE Use and Care Guide - Page 8
See Fools - parts
UPC - 883049141138
View all Maytag MHWZ600TE manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 8 highlights
Recommended installation spacing for cabinet installation The dimensions shown are for the recommended spacing. For cabinet installation, with a door, the minimum ventilation openings in the top are required. " , ) 7"(17.8ore) (22,9crn) '"7 ........... The washer can be installed using the standpipe drain system (floor or wall), the laundry tub drain system, or the floor drain system. Select the drain hose installation method you need. See "Fools and Parts." Standpipe drain system - wall or floor (views A & B) The standpipe drain requires a minimum diameter standpipe of 2" (5 cm). The mmirnunl carry-away capacity can be no less than 17 gal. (64 l) per minute. The top of the standpipe must be at least 30" (76.2 cm) high and no higher than 96" (2.4 m) from the bottom of the washer. 30" rain. (76,2 cm) 4 (10,2cm) 31Y2 1 (80cm) (2,5cm) (2,5cm) (68,6cm) (2,5cm) Laundry tub drain system (view C) The laundry tub needs a minimum 20 gal. (76 I) capacity. at least _¢0" (76.2 cm) above the floor. The top of the laundry tub must be Floor drain system (view D) The floor drain system requires a siphon break that may be purchased and Parts." separately. See "Fools The siphon break must be a minimum of 28" (71 cm) from the bottom of the washer. Additional hoses might be needed. 26"_mi_'n_, 7t C D 8