Setup: Item Settings, 1: Recording Marks are not added to the HD SDI signal in default mode.

Page 168 highlights

Item FR SUPER No. DISP. 180 BATTERY SEL 181 TYPE-A NEAR 182 TYPE-A END 183 TYPE-B NEAR 184 TYPE-B END Setting FR SUPER No. DISP. Settings and brief function description 0000 0001 0002 0003 0004 0005 0006 NiCd12 NiCd13 NiCd14 S-LION I-LION TYPE-A TYPE-B Sets the battery type. 0: Settings for 1 pc. 12 V battery (NEAR: 11.2 V, END: 10.6 V) 1: Settings for 1 pc. 13 V battery (NEAR: 12.0 V, END: 10.6 V) 2: Settings for 1 pc. 14 V battery (NEAR: 13.6 V, END: 10.6 V) 3: Settings for 1 pc. lithium-ion battery (BP-L90A) (NEAR: 11.0 V, END: 10.6 V) 4: Settings for 1 pc. lithium-ion battery (ENDURA80) (NEAR: 13.4 V, END: 10.6 V) 5: Battery specified by setup menu No. 181 (TYPE-A NEAR) and No. 182 (TYPE-A END). 6: Battery specified by setup menu No. 183 (TYPE-B NEAR) and No. 184 (TYPE-B END). 0000 | 0023 | 0044 10.6 | 12.9 | 15.0 Specifies the voltage (in 0.1 V steps) when the counter display will flash to warn that the voltage of TYPE-A battery selected by menu No. 180 (BATTERY SEL) has dropped. NOTE: • When a setting is made in the vicinity of 15.0 V, the counter display may flash also when AC power is used. • A setting that is smaller than END cannot be made. 0000 | 0018 | 0034 10.6 | 12.4 | 14.0 Specifies the voltage (in 0.1 V steps) when this unit will automatically power off because the voltage of TYPE-A battery selected by menu No. 180 (BATTERY SEL) has dropped. NOTE: A setting that is larger than NEAR cannot be made. 0000 | 0023 | 0044 10.6 | 12.9 | 15.0 Specifies the voltage (in 0.1 V steps) when the counter display will flash to warn that the voltage of TYPE-B battery selected by menu No. 180 (BATTERY SEL) has dropped. NOTE: • When a setting is made in the vicinity of 15.0 V, the counter display may flash also when AC power is used. • A setting that is smaller than END cannot be made. 0000 | 0018 | 0034 10.6 | 12.4 | 14.0 Specifies the voltage (in 0.1 V steps) when this unit will automatically power off because the voltage of TYPE-B battery selected by menu No. 180 (BATTERY SEL) has dropped. NOTE: A setting that is larger than NEAR cannot be made. Panasonic camera-recorders, recording formats and recording/stopping signals (Recording Mark) Model AJ-HDC27F,H AJ-HDX400P AJ-HDX400E AJ-HDX900 AG-HPX500/502 AG-HPX170/171/172/174 AG-HPX300/301/302/304 AJ-HPX2000/2100 AJ-HPX3000*2 AJ-HPX2700 AJ-HPX3700*2 Recording format 720/**p over 60p 1080/59.94i 1080/50i 1080/25p over 50i 720/59.94p 720/23.98p over 59.94p 720/29.97p over 59.94p 1080/59.94i 1080/23.98p over 59.94i 1080/29.97p over 59.94i 1080/50i 1080/25p over 50i 720/50p 720/50p over 50p 720/**p 1080/**i Recording Mark TYPE TYPE1 *1 *1 *1 TYPE1 TYPE1 TYPE1 *1 TYPE2 *1 *1 *1 TYPE1 TYPE1 TYPE1, 2 Remarks Provides switching between TYPE1 and TYPE2. For operating details, see respective operating instructions. TYPE 2 *1: Recording Marks are not added to the HD SDI signal in default mode. *2: Only recording format of 1080/**i is available. 168 Setup: Item Settings

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218

168
Setup: Item Settings
Panasonic camera-recorders, recording formats and recording/stopping signals (Recording Mark)
*1: Recording Marks are not added to the HD SDI signal in default mode.
*2: Only recording format of 1080/**i is available.
180
BATTERY SEL
0000
0001
0002
0003
0004
0005
0006
NiCd12
NiCd13
NiCd14
S-LION
I-LION
TYPE-A
TYPE-B
Sets the battery type.
0:
Settings for 1 pc. 12 V battery (NEAR: 11.2 V, END: 10.6 V)
1:
Settings for 1 pc. 13 V battery (NEAR: 12.0 V, END: 10.6 V)
2:
Settings for 1 pc. 14 V battery (NEAR: 13.6 V, END: 10.6 V)
3:
Settings for 1 pc. lithium-ion battery (BP-L90A) (NEAR: 11.0 V, END: 10.6 V)
4:
Settings for 1 pc. lithium-ion battery (ENDURA80) (NEAR: 13.4 V, END: 10.6 V)
5:
Battery specified by setup menu No. 181 (TYPE-A NEAR) and No. 182 (TYPE-A END).
6:
Battery specified by setup menu No. 183 (TYPE-B NEAR) and No. 184 (TYPE-B END).
181
TYPE-A NEAR
0000
|
0023
|
0044
10.6
|
12.9
|
15.0
Specifies the voltage (in 0.1 V steps) when the counter display will flash to warn that the
voltage of TYPE-A battery selected by menu No. 180 (BATTERY SEL) has dropped.
NOTE:
• When a setting is made in the vicinity of 15.0 V, the counter display may flash also
when AC power is used.
• A setting that is smaller than END cannot be made.
182
TYPE-A END
0000
|
0018
|
0034
10.6
|
12.4
|
14.0
Specifies the voltage (in 0.1 V steps) when this unit will automatically power off because
the voltage of TYPE-A battery selected by menu No. 180 (BATTERY SEL) has dropped.
NOTE:
A setting that is larger than NEAR cannot be made.
183
TYPE-B NEAR
0000
|
0023
|
0044
10.6
|
12.9
|
15.0
Specifies the voltage (in 0.1 V steps) when the counter display will flash to warn that the
voltage of TYPE-B battery selected by menu No. 180 (BATTERY SEL) has dropped.
NOTE:
• When a setting is made in the vicinity of 15.0 V, the counter display may flash also
when AC power is used.
• A setting that is smaller than END cannot be made.
184
TYPE-B END
0000
|
0018
|
0034
10.6
|
12.4
|
14.0
Specifies the voltage (in 0.1 V steps) when this unit will automatically power off because
the voltage of TYPE-B battery selected by menu No. 180 (BATTERY SEL) has dropped.
NOTE:
A setting that is larger than NEAR cannot be made.
Model
Recording format
Recording Mark TYPE
Remarks
AJ-HDC27F,H
720/**p over 60p
TYPE1
AJ-HDX400P
1080/59.94i
*1
Provides switching between TYPE1 and TYPE2.
For operating details, see respective operating
instructions.
AJ-HDX400E
1080/50i
*1
1080/25p over 50i
*1
AJ-HDX900
720/59.94p
TYPE1
720/23.98p over 59.94p
TYPE1
720/29.97p over 59.94p
TYPE1
1080/59.94i
*1
1080/23.98p over 59.94i
TYPE2
1080/29.97p over 59.94i
*1
1080/50i
*1
1080/25p over 50i
*1
720/50p
TYPE1
720/50p over 50p
TYPE1
AG-HPX500/502
AG-HPX170/171/172/174
AG-HPX300/301/302/304
AJ-HPX2000/2100
AJ-HPX3000
*2
AJ-HPX2700
AJ-HPX3700
*2
720/**p
TYPE1, 2
1080/**i
TYPE 2
Item
Setting
Settings and brief function description
FR
No.
SUPER
DISP.
FR
No.
SUPER
DISP.