Ricoh SP4100N Software User Guide - Page 222
sntp, Time-zone configuration
UPC - 026649027994
View all Ricoh SP4100N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 222 highlights
6. Monitoring and Configuring the Printer Configuring a sending protocol for SNMP v3 TRAP msh> snmp v3trap {1-5} active {ipv4|ipv6|ipx} {on|off} Configuring a user account for SNMP v3 TRAP msh> snmp v3trap {1-5} account "account_name" • Enter an account name using up to 32 alphanumeric characters. Deleting an SNMP v3 TRAP user account msh> snmp v3trap {1-5} clear account Configuring an SNMP v3 encryption algorithm msh> snmp v3auth {md5|sha1} Configuring SNMP v3 encryption msh> snmp v3priv {auto|on} • Set "auto" for automatic encryption configuration • Set "on" for mandatory encryption configuration. 6 sntp The printer clock can be synchronized with a NTP server clock using Simple Network Time Protocol (SNTP). Use the "sntp" command to change SNTP settings. View settings msh> sntp NTP server address configuration You can specify the IP address of the NTP server. msh> sntp server "IP_address" Interval configuration msh> sntp interval "polling_time" • You can specify the interval at which the printer synchronizes with the operator-specified NTP server. The default is 60 minutes. • The interval can be entered from 0, or between 16 and 10,080 minutes. • If you set 0, the printer synchronizes with the NTP server only when you turn the printer on. After that, the printer does not synchronize with the NTP server. Time-zone configuration msh> sntp timezone "+/-hour_time" • You can specify the time difference between the printer clock and NTP server clock. The values are between -12:00 and +13:00. 220