Cisco SGE2000 Configuration Guide - Page 55

Power Supply Specifications, Powering Down the Power Supply Unit and Disconnecting Input Power

Page 55 highlights

Chapter 4 Installation and Maintenance Removing and Replacing a Power Supply Unit Note Simple Network Management Protocol (SNMP) monitors the activity of the power supplies. In most cases when a power supply problem occurs, an SNMP trap is sent in SNMP and the appropriate message is posted on the SCE 2000 CLI. Power Supply Specifications The following table lists the AC-input and DC-input power supply specifications for the SCE 2000 platform: Table 4-7 Table 4 7 SCE 2000 Power Supply Specifications AC-input power AC-input voltage rating AC-input current rating AC-input frequency rating AC-input cable DC-input power DC-input voltage rating DC-input current rating DC-input cable DC-input circuit breaker 200W maximum 100 to 240 VAC Rated for 4.5A when Vin = 100 VAC or 2A when Vin = 200 VAC 50 to 60 Hz 18 AWG three-wire cable, with a three-lead IEC-320 receptacle on the power supply end, and a country-dependent plug on the power source end. 200W maximum -48/-60 VDC nominal (-36 to-72 VDC supply tolerance) 7A at -48 VDC 12 AWG or 2.5-mm copper installation wire with hex or loop connectors One Fast 10A for each power supply unit Note For AC-input power, we recommend powering the SCE 2000 platform from a 120 VAC, 15A receptacle U.S. (240 VAC, 10A international) at the power source. Powering Down the Power Supply Unit and Disconnecting Input Power The following sections describe how to remove power from an AC-input power supply and a DC-input power supply: • How to Power Down an AC-Input Power Supply • How to Power Down a DC-Input Power Supply Unit and Remove the DC-Input Leads How to Power Down an AC-Input Power Supply To power down an AC-input power supply to the SCE 2000 platform, complete the following steps: OL-7824-06 Cisco SCE 2000 4xGBE Installation and Configuration Guide 4-17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142

4-17
Cisco SCE 2000 4xGBE Installation and Configuration Guide
OL-7824-06
Chapter 4
Installation and Maintenance
Removing and Replacing a Power Supply Unit
Note
Simple Network Management Protocol (SNMP) monitors the activity of the power supplies. In most
cases when a power supply problem occurs, an SNMP trap is sent in SNMP and the appropriate message
is posted on the
SCE 2000
CLI.
Power Supply Specifications
The following table lists the AC-input and DC-input power supply specifications for the
SCE 2000
platform:
Note
For AC-input power, we recommend powering the
SCE 2000
platform from a 120 VAC, 15A receptacle
U.S. (240 VAC, 10A international) at the power source.
Powering Down the Power Supply Unit and Disconnecting Input Power
The following sections describe how to remove power from an AC-input power supply and a DC-input
power supply:
How to Power Down an AC-Input Power Supply
How to Power Down a DC-Input Power Supply Unit and Remove the DC-Input Leads
How to Power Down an AC-Input Power Supply
To power down an AC-input power supply to the
SCE 2000
platform, complete the following steps:
Table 4-7
Table 4 7 SCE 2000 Power Supply Specifications
AC-input power
200W maximum
AC-input voltage rating
100 to 240 VAC
AC-input current rating
Rated for 4.5A when Vin = 100 VAC or 2A when
Vin = 200 VAC
AC-input frequency rating
50 to 60 Hz
AC-input cable
18 AWG three-wire cable, with a three-lead
IEC-320 receptacle on the power supply end, and
a country-dependent plug on the power source
end.
DC-input power
200W maximum
DC-input voltage rating
–48/-60 VDC nominal (–36 to–72 VDC supply
tolerance)
DC-input current rating
7A at –48 VDC
DC-input cable
12 AWG or 2.5-mm copper installation wire with
hex or loop connectors
DC-input circuit breaker
One Fast 10A for each power supply unit