HP LH4r HP Netserver LP 1000r User Guide - Page 122
See
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 122 highlights
Chapter 13 Alternative Rack Mounting (4-Post) Preparing the Rack The outer-rail assemblies must be released after shipment and the columns must be marked before mounting the outer-rail assemblies. Once the outer-rails are correctly mounted, then the HP Netserver LP 1000r can be installed into the rack. A template is not provided because the Netserver is exactly one EIA unit high and can only fit into one EIA unit, but not across two EIA units. NOTE The HP Netserver weighs 32 lbs. (14.5 kg.) fully loaded. It is not necessary to use two people when placing the Netserver into the rack, but it may be helpful. HP Netserver Rack Mount Parts List Ensure the rack-mounting kit provided with the HP Netserver contains the following parts: Table 13-1. Parts for Rack Mount Kit Quantity Description 2 Outer-rail assembly Releasing Outer-Rail Assemblies This is only required the first time the outer-rail assemblies are shipped. The outer-rails are compressed for shipping and held in place with two 10-mm nuts. These nuts must be turned turn to release the spring assembly and then turned back to hold the spring assembly in place with freedom to move back and forth. See Figure 13-2. 1. Turn both nuts counterclockwise (CCW) ¾ of a turn to release the spring assembly. 2. Turn both nuts back clockwise (CW) ¼ of a turn to hold the spring assembly in place. The spring assembly must be able to move freely back and forth to aid in installation of the outer-rails into the rack. 116