HP LH4r HP Netserver LP 1000r User Guide - Page 124
Attaching Outer-Rails to the Rack
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 124 highlights
Chapter 13 Alternative Rack Mounting (4-Post) Rear of Rack represents the EIA unit numbers on the rack columns. 3rd Hole From Bottom 1st Hole From Bottom Masking Tape Marker Left Side Mark this face of the columns with masking tape or marker pen. Right Side Bottom of HP NetServer Front of Rack Figure 13-3. Location Marks on the Rack's Columns 3. Mark the inside face of the left-rear and right-rear rack columns, with masking tape, as shown in Figure 13-3. Attaching Outer-Rails to the Rack No tools are required to attach the outer-rail assemblies to the rack columns. 1. Pull the anti-tip foot forward out of the bottom of the rack. See Figure 13-4 for the anti-tip foot location. 2. Lower the leveler screws on the rack's lower four corners to make firm contact with the floor. See Figure 13-4. 3. Align the left outer-rail assembly to the left front and rear columns as shown in Figure 13-4. 4. Match the outer-rail pins to the column holes (1st & 3rd) marked on the front and rear columns. See Figure 13-3. The mounting pins of the outer-rails should go into the inside face of the rear column and front face of the front column. 118