HP LH4r HP Netserver LP 1000r User Guide - Page 28
SCSI connector failed to engage the SCSI connector at the rear of the Hot
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
Chapter 3 Installing Mass Storage Devices 6. Verify the tab on each ejector arm engages the edge of the drive bay as you close it. See Figure 3-4. You should feel each ejector arm click into place when it closes completely. Closing both ejector arms engages the drive with the electrical connector at the rear of the Hot Swap drive bay and seats the drive. Drive Ejector Arms Closing Ejector Arm Locking tab pivots when ejector arm is opened or closed. Figure 3-4. Closing Drive Ejector Arms 7. If the drive is unseated in the drive bay after closing both ejector arms, repeat this procedure from Step 2 to 5. The ejector arms may not have opened enough to engage the tab, or the SCSI connector failed to engage the SCSI connector at the rear of the Hot Swap drive bay. NOTE Closing both ejector arms will ensure the drive connector engages the electrical connector in the Hot Swap drive bay and seats the drive. 22