HP LH4r HP Netserver LP 1000r User Guide - Page 23

SCSI Device Installation Order

Page 23 highlights

Chapter 3 Installing Mass Storage Devices • SCSI Drive Addressing ◊ The addresses of the SCSI drives are automatically assigned by the drive bay location in the chassis. Refer to Figure 3-1. No SCSI ID software settings or jumpers are required if using a HP NetRAID Controller board inserted into the only PCI slot. • SCSI Device Installation Order The three Hot Swap bays support various SCSI HDD configurations. ◊ Start from the left side of the chassis when adding Hot Swap SCSI hard drives in the HP Netserver. • Filler Panels ◊ Ensure all empty bays in the chassis have filler panels inserted before powering on the Netserver to ensure proper airflow. If there are empty bays, the existing drives and the Netserver may not receive the proper ventilation and could suffer thermal damage. CAUTION To prevent overheating or excessive electromagnetic radiation, use the filler panels to fill the empty bays. If the filler panels are left out of the drive bays, thermal damage and/or excessive EMI could occur. Drive Bay 2 CD-ROM Flexible Disk Drive (FDD) Drive Bay 1 Drive Bay 3 SCSI ID 0 Drive Bay 4 SCSI ID 1 Drive Bay 5 SCSI ID 2 Figure 3-1. HP Netserver Drive Bays 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140

Chapter 3
Installing Mass Storage Devices
17
SCSI Drive Addressing
The addresses of the SCSI drives are automatically assigned by the
drive bay location in the chassis. Refer to Figure 3-1.
No SCSI ID software settings or jumpers are required if using a HP
NetRAID Controller board inserted into the only PCI slot.
SCSI Device Installation Order
The three Hot Swap bays support various SCSI HDD configurations.
Start from the left side of the chassis when adding Hot Swap SCSI hard
drives in the HP Netserver.
Filler Panels
Ensure all empty bays in the chassis have filler panels inserted before
powering on the Netserver to ensure proper airflow. If there are empty
bays, the existing drives and the Netserver may not receive the proper
ventilation and could suffer thermal damage.
CAUTION
To prevent overheating or
excessive electromagnetic
radiation, use the filler panels to fill the empty bays. If the
filler panels are left out of the drive bays, thermal damage
and/or excessive EMI could occur.
CD-ROM
Flexible Disk Drive (FDD)
SCSI
ID 0
SCSI ID 1
SCSI ID 2
Drive Bay 1
Drive Bay 2
Drive Bay 3
Drive Bay 4
Drive Bay 5
Figure 3-1. HP Netserver Drive Bays