9: PC Cards Enable NAT Select to enable Network Address Translation (NAT) for dial-in and dial-out PPP connections on a per modem (Device Port or PC Card) basis. Users dialing into the SLC console manager access the network connected to Eth1 and/or Eth2. Note: IP forwarding must be enabled on the Network - Settings page for NAT to work. To enable, click the IP Forwarding link to display the Network Settings page. Dial-out Number Phone number for dialing out to a remote system or serial device. May have up to 20 characters. Any format is acceptable. Dial-out Login User ID for dialing out to a remote system. May have up to 32 characters. Dial-out Password Password for dialing out to a remote system. May have up to 64 characters. and Retype Restart Delay The number of seconds after the timeout and before the SLC console manager attempts another connection. The default is 30 seconds. CBCP Server Allow No Callback For CBCP Server state, allows "No Callback" as an option in the CBCP handshake in addition to User-defined Number and Admin-defined Number. For more information about CBCP, see Modem State Parameters on page 277. CBCP Client Type For CBCP Client, this selects the number that the client would like to use for callback - either a user-defined number passed to the server (specified by the Fixed Dial-back Number) or an administrator-defined number determined by the server based on the login that is PAP or CHAP authenticated. For more information about CBCP, see Modem State Parameters on page 277. IP Settings Service Telnet Port SSH Port TCP Port The available connection services for the modem port. Check Telnet, SSH, or TCP to enable. Only one can be active at a time. The default is None. Telnet session port number to use if you selected Telnet. Defaults:  Upper PC Card Slot: 2049  Lower PC Card Slot: 2050  Range: 1025-65535  Authenticate: Checkbox and if selected, the SLC console manager requires user authentication before granting access to the port. Authenticate is selected by default for Telnet Port and SSH Port, but not for TCP Port. The SSH session port number to use if you selected SSH. Defaults:  Upper PC Card Slot: 3049  Lower PC Card Slot: 3050  Range: 1025-65535  Authenticate: Checkbox and if selected, the SLC device requires user authentication before granting access to the port. Authenticate is selected by default for Telnet Port and SSH Port, but not for TCP Port. The TCP (raw) session port number to use if you selected TCP. Defaults:  Upper PC Card Slot: 4049  Lower PC Card Slot: 4050  Range: 1025-65535  Authenticate: Checkbox and if selected, the SLC console manager requires user authentication before granting access to the port. Authenticate is selected by default for Telnet Port and SSH Port, but not for TCP Port. 6. Click the Apply button. SLC™ Console Manager User Guide 125

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299

9: PC Cards
SLC™ Console Manager User Guide
125
IP Settings
6.
Click the
Apply
button.
Enable NAT
Select to enable Network Address Translation (NAT) for dial-in and dial-out PPP
connections on a per modem (Device Port or PC Card) basis. Users dialing into
the SLC console manager access the network connected to Eth1 and/or Eth2.
Note:
IP forwarding must be enabled on the Network - Settings page for NAT to
work. To enable, click the
IP Forwarding
link to display the Network Settings
page.
Dial-out Number
Phone number for dialing out to a remote system or serial device. May have up to
20 characters. Any format is acceptable.
Dial-out Login
User ID for dialing out to a remote system. May have up to 32 characters.
Dial-out Password
and Retype
Password for dialing out to a remote system. May have up to 64 characters.
Restart Delay
The number of seconds after the timeout and before the SLC console manager
attempts another connection. The default is
30
seconds.
CBCP Server Allow
No Callback
For CBCP Server state, allows “No Callback” as an option in the CBCP handshake
in addition to User-defined Number and Admin-defined Number. For more
information about CBCP, see
Modem State Parameters on page 277
.
CBCP Client Type
For CBCP Client, this selects the number that the client would like to use for
callback - either a user-defined number passed to the server (specified by the
Fixed Dial-back Number) or an administrator-defined number determined by the
server based on the login that is PAP or CHAP authenticated. For more
information about CBCP, see
Modem State Parameters on page 277
.
Service
The available connection services for the modem port. Check Telnet, SSH, or TCP
to enable. Only one can be active at a time. The default is
None
.
Telnet Port
Telnet session port number to use if you selected
Telnet
. Defaults:
Upper PC Card Slot:
2049
Lower PC Card Slot:
2050
Range:
1025-65535
Authenticate
: Checkbox and if selected, the SLC console manager requires
user authentication before granting access to the port.
Authenticate
is selected
by default for
Telnet Port
and
SSH Port,
but not for
TCP Port
.
SSH Port
The SSH session port number to use if you selected
SSH
. Defaults:
Upper PC Card Slot:
3049
Lower PC Card Slot:
3050
Range:
1025-65535
Authenticate
: Checkbox and if selected, the SLC device requires user
authentication before granting access to the port.
Authenticate
is selected by
default for
Telnet Port
and
SSH Port,
but not for
TCP Port
.
TCP Port
The TCP (raw) session port number to use if you selected
TCP
. Defaults:
Upper PC Card Slot:
4049
Lower PC Card Slot:
4050
Range:
1025-65535
Authenticate
: Checkbox and if selected, the SLC console manager requires
user authentication before granting access to the port.
Authenticate
is selected
by default for
Telnet Port
and
SSH Port,
but not for